Energy metabolism is tightly linked with circadian rhythms, exposure to ambient light, sleep/wake, fasting/eating, and rest/activity cycles. External factors, such as shift work, lead to a disruption of these rhythms, often called circadian misalignment. Circadian misalignment has an impact on some physiological markers. However, these proxy measurements do not immediately translate into major clinical health outcomes, as shown by later detrimental health effects of shift work and cardio-metabolic disorders. This review focuses on the effects of shift work on circadian rhythms and its implications in cardio-metabolic disorders and eating patterns. Shift work appears to be a risk factor of overweight, obesity, type 2 diabetes, elevated blood pressure, and the metabolic syndrome. However, past studies showed discordant findings regarding the changes of lipid profile and eating patterns. Most studies were either small and short lab studies, or bigger and longer cohort studies, which could not measure health outcomes in a detailed manner. These two designs explain the heterogeneity of shift schedules, occupations, sample size, and methods across studies. Given the burden of non-communicable diseases and the growing concerns about shift workers’ health, novel approaches to study shift work in real contexts are needed and would allow a better understanding of the interlocked risk factors and potential mechanisms involved in the onset of metabolic disorders.
The advantages of prehabilitation in surgical oncology are unclear. This systematic review aims to (1) evaluate the latest evidence of preoperative prehabilitation interventions on postoperative outcomes after gastrointestinal (GI) cancer surgery and (2) discuss new potential therapeutic targets as part of prehabilitation. Randomized controlled trials published between January 2017 and August 2022 were identified through Medline. The population of interest was oncological patients undergoing GI surgery. Trials were considered if they evaluated prehabilitation interventions (nutrition, physical activity, probiotics and symbiotics, fecal microbiota transplantation, and ghrelin receptor agonists), alone or combined, on postoperative outcomes. Out of 1180 records initially identified, 15 studies were retained. Evidence for the benefits of unimodal interventions was limited. Preoperative multimodal programs, including nutrition and physical activity with or without psychological support, showed improvement in postoperative physical performance, muscle strength, and quality of life in patients with esophagogastric and colorectal cancers. However, there was no benefit for postoperative complications, hospital length of stay, hospital readmissions, and mortality. No trial evaluated the impact of fecal microbiota transplantation or oral ghrelin receptor agonists. Further studies are needed to confirm our findings, identify patients who are more likely to benefit from surgical prehabilitation, and harmonize interventions.
The main source of error in body composition assessment of bedridden patients by bioelectrical impedance analysis (BIA) is the electrode inadequacy and placement. As electrocardiogram (ECG) electrodes are often used for BIA measurements, this study aimed to compare three of them with a reference BIA electrode. BIA was performed sequentially on 24 healthy subjects in the supine position, using 3 different ECG electrodes (3M® Red Dot® 2330; Ambu® BlueSensor 2300; Ambu® BlueSensor SU-00-C) and the reference electrode (Bianostic AT®) for the BIA device (Nutriguard-M®, Data Input, Germany). Resistance (R), reactance (Xc), phase angle (PhA), appendicular skeletal muscle index (ASMI), fat-free mass index (FFMI) and fat mass percentage (FM%) obtained with the different electrodes were compared using Bland-Altman plots, repeated measures one-way ANOVA and paired t-test. Patient characteristics potentially involved in BIA measurement differences were assessed using linear regression analysis. The study population consisted of 9 men and 15 women, 33% and 47% of whom were overweight, respectively. The measured R was within the physiological range for all men (428-561 Ω) and women (472-678 Ω), regardless of the type of electrodes used. Compared to the reference electrode, the 3M® Red Dot® 2330 and Ambu® BlueSensor SU-00-C electrodes gave significantly different Xc and PhA values, but only the Ambu® BlueSensor SU-00-C gave significantly different ASMI, FFMI and FM% at 50 kHz, with biases of -0.2 kg/m2, -0.3 kg/m2 and +1.4%, respectively. The higher the current frequency, the lower was the Xc and PhA measured by the Ambu® BlueSensor SU-00-C compared to the reference electrode. These measurement differences seemed mainly due to the too small gel area of the Ambu® BlueSensor SU-00-C (154 mm2) compared to the reference electrode (1311 mm2). The use of electrodes with small gel area affects BIA measurement in the supine position, especially when PhA is used as an indicator of the nutritional status. Therefore, it is essential to specify the type of electrodes and carry out comparative tests before changing consumables for body composition assessment, to ensure BIA measurement reliability in clinical and research settings.