Weihe Xu

Dr. Weihe Xu


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 August 2018 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
MGMingyuan Ge
Mingyuan Ge
DCDavid Scott Coburn
David Scott Coburn
ENEvgeny Nazaretski
Evgeny Nazaretski
WXWeihe Xu
Weihe Xu
KGKazimierz Gofron
Kazimierz Gofron
WLWah-Keat Lee
Wah-Keat Lee
Full field transmission X-ray microscopy (TXM) is a powerful technique for non-destructive 3D imaging with nanometer-scale spatial resolution. However, to date, the typical acquisition time with the hard X-ray TXM at a synchrotron facility is >10 min for a 3D nano-tomography dataset with sub-50 nm spatial resolution. This is a significant limit on the types of 3D dynamics that can be investigated using this technique. Here, we present a demonstration of one-minute nano-tomography with sub-50 nm spatial resolution. This achievement is made possible with an in-house designed and commissioned TXM instrument at the Full-field X-ray Imaging beamline at the National Synchrotron Light Source-II at Brookhaven National Laboratory. This capability represents an order of magnitude decrease in the time required for studying sample dynamics with 10 s of nm spatial resolution.

1 May 2019 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
DCDavid Scott Coburn
David Scott Coburn
ENEvgeny Nazaretski
Evgeny Nazaretski
WXWeihe Xu
Weihe Xu
MGMingyuan Ge
Mingyuan Ge
CLCindy Longo
Cindy Longo
WLWah-Keat Lee
Wah-Keat Lee
A transmission X-ray microscope has been designed and commissioned at the 18-ID Full-field X-ray Imaging beamline at the National Synchrotron Light Source II. This instrument operates in the 5–11 keV range, and, with the current set of optics, is capable of 30 nm spatial resolution imaging, with a field of view of about 40 μm. For absorption contrast, the minimum exposure time for a single projection image is about 20 ms and an entire 3D tomography data set can be acquired in under 1 min. The system enables tomographic reconstructions with sub-50 nm spatial resolution without the use of markers on the sample or corrections for rotation run-outs.

27 June 2016 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
ENEvgeny Nazaretski
Evgeny Nazaretski
WXWeihe Xu
Weihe Xu
BNBouet Nathalie
Bouet Nathalie
JZJ. Zhou
J. Zhou
HYH. Yan
H. Yan
YCY. S. Chu
Y. S. Chu
We have developed an experimental approach to bond two independent linear Multilayer Laue Lenses (MLLs) together. A monolithic MLL structure was characterized using ptychography at 12 keV photon energy, and we demonstrated 12 nm and 24 nm focusing in horizontal and vertical directions, respectively. Fabrication of 2D MLL optics allows installation of these focusing elements in more conventional microscopes suitable for x-ray imaging using zone plates, and opens easier access to 2D imaging with high spatial resolution in the hard x-ray regime.

29 July 2022 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
ENEvgeny Nazaretski
Evgeny Nazaretski
DCD. S. Coburn
D. S. Coburn
WXWeihe Xu
Weihe Xu
JMJ. Ma
J. Ma
HXH. Xu
H. Xu
YCY. S. Chu
Y. S. Chu
The development, construction, and first commissioning results of a new scanning microscope installed at the 5-ID Submicron Resolution X-ray Spectroscopy (SRX) beamline at NSLS-II are reported. The developed system utilizes Kirkpatrick–Baez mirrors for X-ray focusing. The instrument is designed to enable spectromicroscopy measurements in 2D and 3D with sub-200 nm spatial resolution. The present paper focuses on the design aspects, optical considerations, and specifics of the sample scanning stage, summarizing some of the initial commissioning results.

23 August 2018 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
YGYuan Gao
Yuan Gao
WXWeihe Xu
Weihe Xu
WSWuxian Shi
Wuxian Shi
ASAlexei Soares
Alexei Soares
JJJean Jakoncic
Jean Jakoncic
MFMartin Fuchs
Martin Fuchs
The Frontier Microfocus Macromolecular Crystallography (FMX) beamline at the National Synchrotron Light Source II with its 1 µm beam size and photon flux of 3 × 1012 photons s−1 at a photon energy of 12.66 keV has reached unprecedented dose rates for a structural biology beamline. The high dose rate presents a great advantage for serial microcrystallography in cutting measurement time from hours to minutes. To provide the instrumentation basis for such measurements at the full flux of the FMX beamline, a high-speed, high-precision goniometer based on a unique XYZ piezo positioner has been designed and constructed. The piezo-based goniometer is able to achieve sub-100 nm raster-scanning precision at over 10 grid-linepairs s−1 frequency for fly scans of a 200 µm-wide raster. The performance of the scanner in both laboratory and serial crystallography measurements up to the maximum frame rate of 750 Hz of the Eiger 16M's 4M region-of-interest mode has been verified in this work. This unprecedented experimental speed significantly reduces serial-crystallography data collection time at synchrotrons, allowing utilization of the full brightness of the emerging synchrotron radiation facilities.

15 October 2020 in Micromachines
Verified
Journal Article
Open access
PDF file
WXWei Xu
Wei Xu
WXWeihe Xu
Weihe Xu
BNBouet Nathalie
Bouet Nathalie
JZJuan Zhou
Juan Zhou
HYHanfei Yan
Hanfei Yan
ENEvgeny Nazaretski
Evgeny Nazaretski
We report on a developed micromachined silicon platform for the precise assembly of 2D multilayer Laue lenses (MLLs) for high-resolution X-ray microscopy. The platform is 10 × 10 mm2 and is fabricated on ~500 µm thick silicon wafers through multiple steps of photolithography and deep reactive-ion etching. The platform accommodates two linear MLLs in a pre-defined configuration with precise angular and lateral position control. In this work, we discuss the design and microfabrication of the platform, and characterization regarding MLLs assembly, position control, repeatability, and stability. The results demonstrate that a micromachined platform can be used for the assembly of a variety of MLLs with different dimensions and optical parameters. The angular misalignment of 2D MLLs is well controlled in the range of the designed accuracy, down to a few millidegrees. The separation distance between MLLs is adjustable from hundreds to more than one thousand micrometers. The use of the developed platform greatly simplifies the alignment procedure of the MLL optics and reduces the complexity of the X-ray microscope. It is a significant step forward for the development of monolithic 2D MLL nanofocusing optics for high-resolution X-ray microscopy.