Yuan Gao

Yuan Gao

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 September 2020 in Science Advances
Verified
Journal Article
Open access
PDF file
APAjith Pattammattel
Ajith Pattammattel
RTR. Tappero
R. Tappero
MGM. Ge
M. Ge
YCY. S. Chu
Y. S. Chu
XHXiaojing Huang
Xiaojing Huang
HYH. Yan
H. Yan
Hard x-ray nano-XANES enables high-sensitivity chemical state mapping at the nanoscale and multimodal imaging capability.

25 February 2021 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
DSDieter K. Schneider
Dieter K. Schneider
WSWuxian Shi
Wuxian Shi
BABabak Andi
Babak Andi
JJJean Jakoncic
Jean Jakoncic
YGYuan Gao
Yuan Gao
MFMartin Fuchs
Martin Fuchs
Two new macromolecular crystallography (MX) beamlines at the National Synchrotron Light Source II, FMX and AMX, opened for general user operation in February 2017 [Schneider et al. (2013). J. Phys. Conf. Ser. 425, 012003; Fuchs et al. (2014). J. Phys. Conf. Ser. 493, 012021; Fuchs et al. (2016). AIP Conf. Proc. SRI2015, 1741, 030006]. FMX, the micro-focusing Frontier MX beamline in sector 17-ID-2 at NSLS-II, covers a 5–30 keV photon energy range and delivers a flux of 4.0 × 1012 photons s−1 at 1 Å into a 1 µm × 1.5 µm to 10 µm × 10 µm (V × H) variable focus, expected to reach 5 × 1012 photons s−1 at final storage-ring current. This flux density surpasses most MX beamlines by nearly two orders of magnitude. The high brightness and microbeam capability of FMX are focused on solving difficult crystallographic challenges. The beamline's flexible design supports a wide range of structure determination methods – serial crystallography on micrometre-sized crystals, raster optimization of diffraction from inhomogeneous crystals, high-resolution data collection from large-unit-cell crystals, room-temperature data collection for crystals that are difficult to freeze and for studying conformational dynamics, and fully automated data collection for sample-screening and ligand-binding studies. FMX's high dose rate reduces data collection times for applications like serial crystallography to minutes rather than hours. With associated sample lifetimes as short as a few milliseconds, new rapid sample-delivery methods have been implemented, such as an ultra-high-speed high-precision piezo scanner goniometer [Gao et al. (2018). J. Synchrotron Rad. 25, 1362–1370], new microcrystal-optimized micromesh well sample holders [Guo et al. (2018). IUCrJ, 5, 238–246] and highly viscous media injectors [Weierstall et al. (2014). Nat. Commun. 5, 3309]. The new beamline pushes the frontier of synchrotron crystallography and enables users to determine structures from difficult-to-crystallize targets like membrane proteins, using previously intractable crystals of a few micrometres in size, and to obtain quality structures from irregular larger crystals.

8 January 2021 in Physical Review B
Verified
Journal Article
Closed access
PDF file
YGYuan Gao
Yuan Gao
XHXiaojing Huang
Xiaojing Huang
HYHanfei Yan
Hanfei Yan
GWGarth Williams
Garth Williams
Bragg coherent diffractive imaging (BCDI) is a noninvasive microscopy technique that can visualize the morphology and internal lattice deviations of crystals with nanoscale spatial resolution and picometer deformation sensitivity. While BCDI has been successfully applied in various studies of materials, it is less successful for highly strained crystals. Specifically, it is difficult to correctly reconstruct the electron density of a highly strained object using conventional phase retrieval algorithms. Although various algorithms have been developed to overcome this challenge, most of them require a priori knowledge that is not always available in practice. Here we report a phase retrieval workflow that can invert diffraction patterns from multiple Bragg peaks simultaneously. The workflow is explored via simulated diffraction from crystals with various strain conditions. Reconstructions from the workflow consistently demonstrate more accurate electron density maps, in comparison with the conventional method. For highly strained crystals, the workflow improves the reliability and consistency of BCDI phase retrieval significantly.

14 February 2019 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Closed access
PDF file
YGYuan Gao
Yuan Gao
RHRoss Harder
Ross Harder
SSStephen H. Southworth
Stephen H. Southworth
JGJeffrey R. Guest
Jeffrey R. Guest
XHXiaojing Huang
Xiaojing Huang
LYLinda Young
Linda Young
Significance: Obtaining a fundamental understanding of crystal growth and chemical reactions in solution is of broad and enduring interest for materials discovery, structural biology, and catalysis. The recent availability of bright, coherent X-ray sources can enable these fluctuation-driven processes to be monitored in situ through the technique of coherent X-ray diffractive imaging (CXDI), in which the 3D internal structure of microscopic objects is determined with nanometer resolution from the fine structure of diffraction peaks. So far, Bragg CXDI has required immobilization of particles on a substrate, which modifies their structure and chemical activity. Here, we demonstrate Bragg CXDI on a single particle that is trapped and oriented in solution using optical tweezers and thus obtain its 3D structure and strain map.

23 August 2018 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
YGYuan Gao
Yuan Gao
WXWeihe Xu
Weihe Xu
WSWuxian Shi
Wuxian Shi
ASAlexei Soares
Alexei Soares
JJJean Jakoncic
Jean Jakoncic
MFMartin Fuchs
Martin Fuchs
The Frontier Microfocus Macromolecular Crystallography (FMX) beamline at the National Synchrotron Light Source II with its 1 µm beam size and photon flux of 3 × 1012 photons s−1 at a photon energy of 12.66 keV has reached unprecedented dose rates for a structural biology beamline. The high dose rate presents a great advantage for serial microcrystallography in cutting measurement time from hours to minutes. To provide the instrumentation basis for such measurements at the full flux of the FMX beamline, a high-speed, high-precision goniometer based on a unique XYZ piezo positioner has been designed and constructed. The piezo-based goniometer is able to achieve sub-100 nm raster-scanning precision at over 10 grid-linepairs s−1 frequency for fly scans of a 200 µm-wide raster. The performance of the scanner in both laboratory and serial crystallography measurements up to the maximum frame rate of 750 Hz of the Eiger 16M's 4M region-of-interest mode has been verified in this work. This unprecedented experimental speed significantly reduces serial-crystallography data collection time at synchrotrons, allowing utilization of the full brightness of the emerging synchrotron radiation facilities.

3 May 2019 in IUCrJ
Verified
Journal Article
Open access
PDF file
GGGongrui Guo
Gongrui Guo
PZPing Zhu
Ping Zhu
MFMartin Fuchs
Martin Fuchs
WSWuxian Shi
Wuxian Shi
BABabak Andi
Babak Andi
Qun LiuQun Liu
Qun Liu
De novo structural evaluation of native biomolecules from single-wavelength anomalous diffraction (SAD) is a challenge because of the weakness of the anomalous scattering. The anomalous scattering from relevant native elements – primarily sulfur in proteins and phosphorus in nucleic acids – increases as the X-ray energy decreases toward their K-edge transitions. Thus, measurements at a lowered X-ray energy are promising for making native SAD routine and robust. For microcrystals with sizes less than 10 µm, native-SAD phasing at synchrotron microdiffraction beamlines is even more challenging because of difficulties in sample manipulation, diffraction data collection and data analysis. Native-SAD analysis from microcrystals by using X-ray free-electron lasers has been demonstrated but has required use of thousands of thousands of microcrystals to achieve the necessary accuracy. Here it is shown that by exploitation of anomalous microdiffraction signals obtained at 5 keV, by the use of polyimide wellmounts, and by an iterative crystal and frame-rejection method, microcrystal native-SAD phasing is possible from as few as about 1 200 crystals. Our results show the utility of low-energy native-SAD phasing with microcrystals at synchrotron microdiffraction beamlines.