This paper describes the analysis of the possibility of use of the direct-contact air, gravel, ground heat exchanger (acronym GAHE), patented at the Wroclaw University of Science and Technology, as a means of improving microclimate parameters in dairy cows’ barns. Different possibilities of introducing GAHE to the standard mechanical ventilation system of cowsheds have been proposed and investigated. Based on literature data, the required air parameters in the barns of dairy cows were determined and discussed. Computer simulations were carried out and the results obtained were compared to the baseline model. Year-round changes in microclimate parameters, especially air temperature, relative humidity, and THI index were investigated. The benefits of GAHE use were indicated. The possible increase in the minimum air volume of ventilation during the winter season and the decrease in the maximum values of this parameter in the summer were presented. Indications were made of the systems where the application of GAHE could be the most beneficial. A further research path has been proposed.
This analysis was carried out to present the distribution of energy demand for air heating, air cooling and technology equipment for a warehouse through the year. The supplied energy is used to maintain the assumed temperatures in the rooms and for the needs of technology. During the work, the calculation model of the building was prepared and imported into the calculation program. The simulation was based on the planned building parameters (partitions structure, dimensions, technology) taken from the architectural executive design. Several versions of the structure of the construction and technical equipment have been analyzed. The obtained results show differences in the formation of energy demand and indoor room conditions.
In this manuscript, an analysis of the prospect of using a direct-contact air, gravel, ground heat exchanger (GAHE)—patented and tested at the Wroclaw University of Science and Technology—as a simple and inexpensive way of improving microclimate parameters in horse stables using renewable energy was presented. Different options for introducing a GAHE into the typical HVAC system have been proposed and examined. Using the GAHE calculation model developed based on the research, computer simulations of the GAHE’s interaction with the ventilation system were conducted. The effects of GAHE interaction were compared with a typical solution that does not utilise ground renewable energy. The analyses demonstrate year-round changes in microclimate parameters, particularly in the air temperature, relative humidity, and the THI comfort index. The benefits of using a GAHE as a component that improves comfort for animals and employees, while simultaneously saving energy, were demonstrated. The use of measurement data and computer energy simulations demonstrates the engineering feasibility of including GAHEs in a mechanical ventilation system for a horse stable. The obtained results indicate the potential for improving animal husbandry and employee working conditions without the need to consume additional energy to operate complex HVAC systems.