Wojciech Cepiński

Dr. Wojciech Cepiński

Faculty of Environmental Engineering, Wrocław University of Science and Technology, Wrocław, Dolnośląskie, Poland
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 November 2021 in Energies
Verified
Journal Article
Open access
PDF file
PKPiotr Kowalski
Piotr Kowalski
Pawel SzalanskiPawel Szalanski
Pawel Szalanski
Wojciech CepińskiWojciech Cepiński
Wojciech Cepiński
The paper presents an analysis of the application of an air-to-water electric compressor heat pump (AWHP) for the recovery of waste heat from the exhaust air in a typical multifamily residential building and the use of this heat for space heating, as well as the impact of this solution on the building energy performance (the PPR index). Simulations were performed in TRNSYS for five locations in Poland (Koszalin, Wrocław, Lublin, Białystok, Suwałki), for various heating system parameters (80/60 °C, 75/65 °C, 70/50 °C, 55/45 °C, 35/28 °C), for various temperature limitations of heat pump operation. It was shown that the analyzed system has great potential from an energy and environmental point of view. It can provide significant benefits in terms of the energy performance of the building, depending on the system parameters. The results show that the most energy-efficient system is the one with the lowest heating system temperatures. Moreover, implementing a temperature limitation on the heat pump operation improves its efficiency, but the higher the design parameters of the heating installation and the lower the limitation, the lower the heat pump contribution, and the higher the SCOP and the PPR. The energy effect is also influenced by location, but its scale depends on the parameters of the heating system and the temperature limitation of the heat pump’s operation. It is more significant for lower heating system parameters. This system enables the possibility of further reducing the demand for nonrenewable primary energy by powering the heat pump with photovoltaic cells.

30 December 2021 in Energies
Verified
Journal Article
Open access
PDF file
MBMaciej Besler
Maciej Besler
Wojciech CepińskiWojciech Cepiński
Wojciech Cepiński
PKPiotr Kęskiewicz
Piotr Kęskiewicz
This paper describes the analysis of the possibility of use of the direct-contact air, gravel, ground heat exchanger (acronym GAHE), patented at the Wroclaw University of Science and Technology, as a means of improving microclimate parameters in dairy cows’ barns. Different possibilities of introducing GAHE to the standard mechanical ventilation system of cowsheds have been proposed and investigated. Based on literature data, the required air parameters in the barns of dairy cows were determined and discussed. Computer simulations were carried out and the results obtained were compared to the baseline model. Year-round changes in microclimate parameters, especially air temperature, relative humidity, and THI index were investigated. The benefits of GAHE use were indicated. The possible increase in the minimum air volume of ventilation during the winter season and the decrease in the maximum values of this parameter in the summer were presented. Indications were made of the systems where the application of GAHE could be the most beneficial. A further research path has been proposed.

10 June 2019
Verified
Conference Paper
Open access
PDF file
Wojciech CepińskiWojciech Cepiński
Wojciech Cepiński
Pawel SzalanskiPawel Szalanski
Pawel Szalanski
The article presents the possibility of using exhaust air from ventilation system to increase the efficiency (SCOP, COP, SEER and EER) of commonly used air conditioners with the function of a heat pump. These types of devices are very popular both in residential and in public buildings. The topic discussed in the article is very important, because the widespread increase of the energy efficiency of these devices significantly influences national electricity consumption. The possibility of increasing their efficiency by directing the exhaust air from the ventilation system to the heat exchanger of the air conditioner outdoor unit has been analysed. It has been shown that the use of the simple design solution described in the article allows for a significant increase of the efficiency of these devices (seasonal efficiency even up to 35% at 100% share of exhaust air), reducing the energy consumption and increasing their capacity and operation range. By increasing the share of exhaust air it is possible to ensure year-round operation of the device and even 100% coverage of heat demand.

4 February 2023 in Building and Environment
Verified
Journal Article
Closed access
Pawel SzalanskiPawel Szalanski
Pawel Szalanski
Wojciech CepińskiWojciech Cepiński
Wojciech Cepiński
MSMarderos Ara Sayegh
Marderos Ara Sayegh

7 August 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
Pawel SzalanskiPawel Szalanski
Pawel Szalanski
PKPiotr Kowalski
Piotr Kowalski
Wojciech CepińskiWojciech Cepiński
Wojciech Cepiński
PKPiotr Kęskiewicz
Piotr Kęskiewicz
This article analyzes the possibility of reducing the energy consumption from building heating as a result of lowering the indoor air temperature, which is recommended as a response to the energy crisis. Various values of the set-point temperature (16–22 °C), as well as different scenarios for their changes, were assumed for analysis. Changes in clothing that were determined to maintain the same level of thermal comfort after a temperature change were determined. The associated reduction in CO2 emissions emitted into the atmosphere was determined. The effect of reducing CO2 emissions was studied depending on the type of heating source. Simulation calculations were carried out for an exemplary multifamily building. The effect of different building insulations required in Poland over the years 1964–2022 was considered. Analyses were performed for the climatic conditions of cities located in different climatic zones of Poland: Koszalin, Wroclaw, Warsaw, Bialystok, Suwalki. Depending on the scenario, the insulation standard of the building, and the variant of location, the energy reduction achieved ranges from 6.6%/K to 13.2%/K. Taking into account the type of heating source, the reduction in CO2 emissions is from 0.7 to 7.5 kgCO2/(K·m2). The reduction in temperature by 1 or 2 K can be compensated for by wearing an additional sleeveless vest (0.12 clo) or sweater (0.28 clo).

7 November 2017 in E3S Web of Conferences
Verified
Conference Paper
Open access
PDF file
Wojciech CepińskiWojciech Cepiński
Wojciech Cepiński
MBMaciej Besler
Maciej Besler
The paper describes the analysis of possibility of using the air direct-contact, gravel, ground heat exchanger (Polish acronym BGWCiM), patented at the Wroclaw University of Science and Technology to prepare air for conditioning rooms in the industry. Indicated the industry sectors where the application may be the most beneficial.