Jianjun Zhu

Dr. Jianjun Zhu

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2024 in APL Bioengineering
Verified
Journal Article
Open access
PDF file
CWCheng Wang
Cheng Wang
LGLi Guo
Li Guo
JZJianjun Zhu
Jianjun Zhu
LZLifeng Zhu
Lifeng Zhu
CLChichi Li
Chichi Li
ZJZhongliang Jiang
Zhongliang Jiang
Cancer, with high morbidity and high mortality, is one of the major burdens threatening human health globally. Intervention procedures via percutaneous puncture have been widely used by physicians due to its minimally invasive surgical approach. However, traditional manual puncture intervention depends on personal experience and faces challenges in terms of precisely puncture, learning-curve, safety and efficacy. The development of puncture interventional surgery robotic (PISR) systems could alleviate the aforementioned problems to a certain extent. This paper attempts to review the current status and prospective of PISR systems for thoracic and abdominal application. In this review, the key technologies related to the robotics, including spatial registration, positioning navigation, puncture guidance feedback, respiratory motion compensation, and motion control, are discussed in detail.

5 December 2022 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Closed access
PDF file
GZGuifang Zhang
Guifang Zhang
HWHon-Cheng Wong
Hon-Cheng Wong
JZJianjun Zhu
Jianjun Zhu
TATao An
Tao An
CWCheng Wang
Cheng Wang

28 December 2023 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
JZJianjun Zhu
Jianjun Zhu
CWCheng Wang
Cheng Wang
YZYi Zhang
Yi Zhang
MZMeixiao Zhan
Meixiao Zhan
WZWei Zhao
Wei Zhao
GTGao-Jun Teng
Gao-Jun Teng
The augmented intra-operative real-time imaging in vascular interventional surgery, which is generally performed by projecting preoperative computed tomography angiography images onto intraoperative digital subtraction angiography (DSA) images, can compensate for the deficiencies of DSA-based navigation, such as lack of depth information and excessive use of toxic contrast agents. 3D/2D vessel registration is the critical step in image augmentation. A 3D/2D registration method based on vessel graph matching is proposed in this study. For rigid registration, the matching of vessel graphs can be decomposed into continuous states, thus 3D/2D vascular registration is formulated as a search tree problem. The Monte Carlo tree search method is applied to find the optimal vessel matching associated with the highest rigid registration score. For nonrigid registration, we propose a novel vessel deformation model based on manifold regularization. This model incorporates the smoothness constraint of vessel topology into the objective function. Furthermore, we derive simplified gradient formulas that enable fast registration. The proposed technique undergoes evaluation against seven rigid and three nonrigid methods using a variety of data - simulated, algorithmically generated, and manually annotated - across three vascular anatomies: the hepatic artery, coronary artery, and aorta. Our findings show the proposed method’s resistance to pose variations, noise, and deformations, outperforming existing methods in terms of registration accuracy and computational efficiency. The proposed method demonstrates average registration errors of 2.14 mm and 0.34 mm for rigid and nonrigid registration, and an average computation time of 0.51 s.

13 December 2023 in IEEE Sensors Journal
Verified
Journal Article
Closed access
TZTianxue Zhang
Tianxue Zhang
AGAnzhu Gao
Anzhu Gao
JZJianjun Zhu
Jianjun Zhu
BZBohan Zhang
Bohan Zhang
JLJiachun Lin
Jiachun Lin
YNYuting Ni
Yuting Ni
Fiber Bragg grating (FBG) optical fiber shape sensing has the potential to minimize harmful radiation exposure for both medical professionals and patients. It provides real-time, three-dimensional visualization of vascular structures during interventional procedures. The field has witnessed advancements through the development of a multi-core 5-FBG sensor array engineered to capture critical attributes inherent to vascular morphology, such as curvature and torsion. An optimized helical extension method (HEM) has been introduced to accurately measure vessel curvature degrees and facilitate precise three-dimensional reconstruction of vascular shapes. This refined HEM algorithm has significantly reduced the reconstruction error rate to 15.611%. An experimental system for interventional vascular optical fiber sensing was established to validate the effectiveness of the proposed method. The obtained vascular shape measurements were compared with those derived from computed tomography (CT) imaging. The maximum error between the two measurements was found to be less than 1.4156 mm, affirming the accuracy of the enhanced HEM algorithm in perceiving vascular shape. This research demonstrates the feasibility of utilizing the constructed multi-core 5-FBGs optical fiber for shape perception in a wide range of vascular structures. This study serves as a foundation for the integration of FBG sensors into clinical vascular shape perception approaches, presenting the potential benefits of reduced radiation exposure and improved accuracy in interventional procedures.

14 January 2026 in Medical Image Analysis
Verified
Journal Article
Open access
TRTobias Rueckert
Tobias Rueckert
DRDavid Rauber
David Rauber
RMRaphaela Maerkl
Raphaela Maerkl
LKLeonard Klausmann
Leonard Klausmann
SYSuemeyye R. Yildiran
Suemeyye R. Yildiran
Christoph PalmChristoph Palm
Christoph Palm
Reliable recognition and localization of surgical instruments in endoscopic video recordings are foundational for a wide range of applications in computer- and robot-assisted minimally invasive surgery (RAMIS), including surgical training, skill assessment, and autonomous assistance. However, robust performance under real-world conditions remains a significant challenge. Incorporating surgical context - such as the current procedural phase - has emerged as a promising strategy to improve robustness and interpretability. To address these challenges, we organized the Surgical Procedure Phase, Keypoint, and Instrument Recognition (PhaKIR) sub-challenge as part of the Endoscopic Vision (EndoVis) challenge at MICCAI 2024. We introduced a novel, multi-center dataset comprising thirteen full-length laparoscopic cholecystectomy videos collected from three distinct medical institutions, with unified annotations for three interrelated tasks: surgical phase recognition, instrument keypoint estimation, and instrument instance segmentation. Unlike existing datasets, ours enables joint investigation of instrument localization and procedural context within the same data while supporting the integration of temporal information across entire procedures. We report results and findings in accordance with the BIAS guidelines for biomedical image analysis challenges. The PhaKIR sub-challenge advances the field by providing a unique benchmark for developing temporally aware, context-driven methods in RAMIS and offers a high-quality resource to support future research in surgical scene understanding.

7 December 2021 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Closed access
PDF file
SJShenghao Jiang
Shenghao Jiang
STSitong Teng
Sitong Teng
JLJian Lu
Jian Lu
Cheng WangCheng Wang
Cheng Wang
TWTiexiang Wen
Tiexiang Wen
GTGao-Jun Teng
Gao-Jun Teng