Cancer, with high morbidity and high mortality, is one of the major burdens threatening human health globally. Intervention procedures via percutaneous puncture have been widely used by physicians due to its minimally invasive surgical approach. However, traditional manual puncture intervention depends on personal experience and faces challenges in terms of precisely puncture, learning-curve, safety and efficacy. The development of puncture interventional surgery robotic (PISR) systems could alleviate the aforementioned problems to a certain extent. This paper attempts to review the current status and prospective of PISR systems for thoracic and abdominal application. In this review, the key technologies related to the robotics, including spatial registration, positioning navigation, puncture guidance feedback, respiratory motion compensation, and motion control, are discussed in detail.
This study focuses on the flexible tube of a bronchoscope robot used in pulmonary intervention surgery, which is considered as a continuum robot. The dynamics model is proposed based on the Koopman operator, leveraging real data to solve for the system matrix parameters accurately. To enhance control precision, we designed a model predictive control (MPC) algorithm aimed at tracking the desired curvature and deflection angles of the flexible tube. The MPC controller uses real-time data from electromagnetic sensors to adjust the tube shape, ensuring accurate and responsive manipulation. The effectiveness of the proposed algorithm are validated through extensive experiments conducted on the Binary experimental platform. Compared with the traditional open-loop control method, the proposed algorithm has achieved significant improvements in tracking performance and operational reliability. Each system state error of the proposed algorithm is smaller, which means that better tracking performance can be obtained under the proposed MPC scheme.
Percutaneous puncture is a pivotal technique in diagnosing and treating hepatic lesions; however, traditional manual puncture methods rely heavily on the expertise of medical practitioners. This study aimed to evaluate the feasibility, safety, and efficacy of percutaneous needle placement through the innovative utilization of computed tomography–ultrasound fusion-guided robotic assistance in abdominal phantom and porcine liver models. The abdominal phantom and eight Bama miniature pigs were selected as experimental subjects. Two puncture methods (handheld and robot-assisted puncture) were administered to each simulated tumor with an 18-gauge biopsy needle. All pigs exhibited stable conditions without any complications following the puncture. The Euclidean distance between the needle tip and the predetermined target point of robot-assisted puncture was 3.30 ± 1.48 mm in the pig model and 2.15 ± 0.82 mm in the phantom model. The planning time required for the physician to perform robot-assisted needle insertion was 8.25 ± 2.59 min. Robot-assisted needle insertion in percutaneous puncture was accurate and safe in the pig liver model, highlighting its feasibility and potential clinical application.