Background: Continuous long-term electrocardiography monitoring has been increasingly recognized for early diagnosis and management of different types of cardiovascular diseases. To find an alternative to Ag/AgCl gel electrodes that are improper for this application scenario, many efforts have been undertaken to develop novel flexible dry textile electrodes integrated into the everyday garments. With significant progresses made to address the potential issues (e.g., low signal-to-noise ratio, high skin–electrode impedance, motion artifact, and low durability), the lack of standard evaluation procedure hinders the further development of dry electrodes (mainly the design and optimization). Results: A standard testing procedure and framework for skin–electrode impedance measurement is demonstrated for the development of novel dry textile electrodes. Different representative electrode materials have been screen-printed on textile substrates. To verify the performance of dry textile electrodes, impedance measurements are conducted on an agar skin model using a universal setup with consistent frequency and pressure. In addition, they are demonstrated for ECG signals acquisition, in comparison to those obtained using conventional gel electrodes. Conclusions: Dry textile electrodes demonstrated similar impedance when in raised or flat structures. The tested pressure variations had an insignificant impact on electrode impedance. Looking at the effect of impedance on ECG signals, a noticeable effect on ECG signal performance metrics was not observed. Therefore, it is suggested that impedance alone is possibly not the primary indicator of signal quality. As well, the developed methods can also serve as useful guidelines for future textile dry-electrode design and testing for practical ECG monitoring applications.
Electromyography (EMG) is the resulting electrical signal from muscle activity, commonly used as a proxy for users’ intent in voluntary control of prosthetic devices. EMG signals are recorded with gold standard Ag/AgCl gel electrodes, though there are limitations in continuous use applications, with potential skin irritations and discomfort. Alternative dry solid metallic electrodes also face long-term usability and comfort challenges due to their inflexible and non-breathable structures. This is critical when the anatomy of the targeted body region is variable (e.g., residual limbs of individuals with amputation), and conformal contact is essential. In this study, textile electrodes were developed, and their performance in recording EMG signals was compared to gel electrodes. Additionally, to assess the reusability and robustness of the textile electrodes, the effect of 30 consumer washes was investigated. Comparisons were made between the signal-to-noise ratio (SNR), with no statistically significant difference, and with the power spectral density (PSD), showing a high correlation. Subsequently, a fully textile sleeve was fabricated covering the forearm, with 14 textile electrodes. For three individuals, an artificial neural network model was trained, capturing the EMG of 7 distinct finger movements. The personalized models were then used to successfully control a myoelectric prosthetic hand.
5 February 2022 in Advanced Materials Technologies
Introduction: In recent years, electromyography (EMG) has been increasingly studied for wearable applications. Conventional gel electrodes for electrophysiological recordings have limited use in everyday applications such as prosthetic control or muscular therapy at home. This study investigates the efficacy and feasibility of dry-contact electrode materials employed in smart textiles for EMG recordings. Methods: Dry-contact electrode materials were selected and implemented on textile substrates. Using these electrodes, EMG was recorded from the forearm of able-bodied subjects. 25% and 50% isometric maximum voluntary contractions were captured. A comparative investigation was performed against gel electrodes, assessing the effect of material properties on signal fidelity and strength compared. Results: When isolating for electrode surface area and pressure, 31 of the 40 materials demonstrated strong positive correlations in their mean PSD with gel electrodes (r > 95, p < 0.001). The inclusion of ionic liquids in the material composition, and using raised or flat electrodes, did not demonstrate a significant effect in signal quality. Conclusions: For EMG dry-contact electrodes, comparing the performance against gel electrodes for the application with the selected material is important. Other factors recommended to be studied are electrodes’ durability and long-term stability.
The connection between flexible textiles and stiff electronic components has always been structurally weak and a limiting factor in the establishment of smart textiles in our everyday life. This paper focuses on the formation of reliable connections between conductive textiles and conventional litz wires using ultrasonic welding. The paper offers a promising approach to solving this problem. The electrical and mechanical performance of the samples were investigated after 15 and 30 wash-and-dry cycles in a laundry machine. Here the contact resistances and their peeling strength were measured. Furthermore, their connection properties were analysed in microsections. The resistance of the joints increased more than 300%, because the silver-coated wires suffered under the laundry cycles. Meanwhile, the mechanical strength during the peeling test decreased by only about 20% after 15 cycles and remained the same after 30 cycles. The good results obtained in this study suggest that ultrasonic welding offers a useful approach to the connection of textile electronics to conductive wires and to the manufacture of smart textiles.
21 May 2021 in IEEE Journal of Biomedical and Health Informatics
Smart textiles provide an opportunity to simultaneously record various electrophysiological signals, e.g., ECG, from the human body in a non-invasive and continuous manner. Accurate processing of ECG signals recorded using textile sensors is challenging due to the very low signal-to-noise ratio (SNR). Signal processing algorithms that can extract ECG signals out of textile-based electrode recordings, despite low SNR are needed. Presently, there are no textile ECG datasets available to develop, test and validate these algorithms. In this paper we attempted to model textile ECG signals by adding the textile sensor noise to open access ECG signals. We employed the linear predictive coding method to model different features of this noise. By approximating the linear predictive coding residual signals using Kernel Density Estimation, an artificial textile ECG noise signal was generated by filtering the residual signal with the linear predictive coding coefficients. The synthetic textile sensor noise was added to the MIT-BIH Arrhythmia Database (MITDB), thus creating Textile-like ECG dataset consisting of 108 trials (30 min each). Furthermore, a Python code for generating textile-like ECG signals with variable SNR was also made available online. Finally, to provide a benchmark for the performance of R-peak detection algorithms on textile ECG, the five common R-peak detection algorithms: Pan & Tompkins, improved Pan & Tompkins (in Biosppy), Hamilton, Engelse, and Khamis, were tested on textile-like MITDB. This work provides an approach to generating noisy textile ECG signals, and facilitating the development, testing, and evaluation of signal processing algorithms for textile ECGs.