Marta Cecilia Montero

Dr. Marta Cecilia Montero

Instituto de Química, Pontificia Universidad Catolica de Valparaiso, Valparaíso, Chile
+1
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 December 2021 in Materials
Verified
Journal Article
Open access
PDF file
DSDaniela Silva
Daniela Silva
CACamila Arcos
Camila Arcos
Marta Cecilia MonteroMarta Cecilia Montero
Marta Cecilia Montero
CGCarolina Guerra
Carolina Guerra
CUCarola Martinez Ugalde
Carola Martinez Ugalde
Mamié SancyMamié Sancy
Mamié Sancy
The increase in longevity worldwide has intensified the use of different types of prostheses for the human body, such as those used in dental work as well as in hip and knee replacements. Currently, Ti-6Al-4V is widely used as a joint implant due to its good mechanical properties and durability. However, studies have revealed that this alloy can release metal ions or particles harmful to human health. The mechanisms are not well understood yet and may involve wear and/or corrosion. Therefore, in this work, commercial pure titanium and a Ti-6Al-4V alloy were investigated before and after being exposed to a simulated biological fluid through tribological tests, surface analysis, and ionic dissolution characterization by ICP-AES. Before exposure, X-ray diffraction and optical microscopy revealed equiaxed α-Ti in both materials and β-Ti in Ti-6Al-4V. Scratch tests exhibited a lower coefficient of friction for Ti-6Al-4V alloy than commercially pure titanium. After exposure, X-ray photoelectron spectroscopy and surface-enhanced Raman spectroscopy results showed an oxide film formed by TiO2, both in commercially pure titanium and in Ti-6Al-4V, and by TiO and Al2O3 associated with the presence of the alloys. Furthermore, inductively coupled plasma atomic emission spectroscopy revealed that aluminum was the main ion released for Ti-6Al-4V, giving negligible values for the other metal ions.

19 April 2025 in Journal of Materials Research and Technology
Verified
Journal Article
Open access
CRCristián Gino Ramírez
Cristián Gino Ramírez
ALBERTO MONSALVEALBERTO MONSALVE
ALBERTO MONSALVE
Marta Cecilia MonteroMarta Cecilia Montero
Marta Cecilia Montero
JEJ. Espinoza
J. Espinoza
JAJ. Araujo
J. Araujo
MPM.A. Páez
M.A. Páez

14 March 2023 in Materials
Verified
Journal Article
Open access
PDF file
Marta Cecilia MonteroMarta Cecilia Montero
Marta Cecilia Montero
CRCristián Gino Ramírez
Cristián Gino Ramírez
LMLisa Muñoz
Lisa Muñoz
Mamié SancyMamié Sancy
Mamié Sancy
Manuel AzocarManuel Azocar
Manuel Azocar
MPMaritza Angelica Páez
Maritza Angelica Páez
Climate change has evidenced the need to reduce carbon dioxide emissions into the atmosphere, and so for transport applications, lighter weight alloys have been studied, such as magnesium alloys. However, they are susceptible to corrosion; therefore, surface treatments have been extensively studied. In this work, the influence of argon plasma pretreatment on the surface properties of an AZ31 magnesium alloy focus on the enhancement of the reactivity of the surface, which was examined by surface analysis techniques, electrochemical techniques, and gravimetric measurements. The samples were polished and exposed to argon plasma for two minutes in order to activate the surface. Contact angle measurements revealed higher surface energy after applying the pretreatment, and atomic force microscopy showed a roughness increase, while X-Ray photoelectron spectroscopy showed a chemical change on the surface, where after pretreatment the oxygen species increased. Electrochemical measurements showed that surface pretreatment does not affect the corrosion mechanism of the alloy, while electrochemical impedance spectroscopy reveals an increase in the original thickness of the surface film. This increase is likely associated with the high reactivity that the plasma pretreatment confers to the surface of the AZ31 alloy, affecting the extent of oxide formation and, consequently, the increase in its protection capacity. The weight loss measurements support the effect of the plasma pretreatment on the oxide thickness since the corrosion rate of the pretreated AZ31 specimens was lower than that of those that did not receive the surface pretreatment.