The accumulated charges on the insulator surface become a key factor to incur surface flashover. The charge accumulation process is closely related to the surface condition. This research investigates the effects of surface roughness on surface charge accumulation behavior and surface flashover performance of alumina-filled epoxy resin spacers in SF6/N2 mixtures under DC voltage. The insulator is prepared with only half surface subjected to rough treatment. The accumulated charges are distributed in two regions. Considerable homo-charges are located near the high voltage (HV) electrode and few hetero-charges are near the grounded (GND) electrode (region I). These charges are injected by electrodes. The bipolar charges between HV and GND electrodes (region II) originate from gas ionization. Surface rough treatment can suppress surface charge accumulation and improve surface insulation strength. When increasing surface roughness, surface charge declines first slowly (stage I) and then rapidly (stage II), which coincides with the two stages of surface flashover voltage increment. Surface charge declination at stage I is mainly due to the increase in surface conductivity, while at stage II, the introduced deep traps also play a role. Surface flashover voltage increment at stage I is mainly due to the extended creepage distance, while at stage II, the declination of surface charge also plays a role. Besides, the block of electron avalanche development by the roughed surface is also responsible for the increase in surface flashover voltage at these two stages.
26 July 2019 in Journal of Physics D: Applied Physics
Surface charge accumulation on insulators becomes an important bottleneck to restrain the development of a DC energy transmission system. This study investigates the effects of SiC/epoxy coating on surface charge behaviors and flashover performance of alumina/epoxy spacers. A nonlinear conductive coating consisting of different contents of SiC fillers and epoxy matrix was fabricated and sprayed on only half surface of the spacers. The dependence of surface charges on the contents of SiC fillers is characterized by three stages. Surface charge accumulation is aggravated at deterioration stage, then almost unaltered at balance stage and inhibited at suppression stage. These three stages are determined by the competition between the increased surface trap density from interface region and the improved surface conductivity from SiC fillers. The variation trend of flashover in air and SF 6 /N 2 mixtures is distinguished by three stages as well. Flashover voltage decreases at descent stage where deficient contents of SiC fillers are appended and then goes up at improved stage with moderate supply of SiC fillers. Finally, it ends up with drastically collapse at degenerated stage when affluent SiC fillers are brought in. The theoretical analysis is proposed based on surface trap distribution and conductivity measurement results to reveal the regulation mechanism of SiC/epoxy coating on surface charge behavior and flashover performance.
10 February 2020 in Journal of Physics D: Applied Physics
Charge accumulation phenomenon on gas–solid interface greatly restricts the development of HVDC energy transmission system. In this study, the surface charge transport behavior and flashover performance on alumina/epoxy spacer coated by SiC/epoxy composites are experimentally investigated under DC stress. SiC/epoxy composites with varied SiC particle size are fabricated and deposited on spacer surface. Nearly a charge free surface is achieved especially at smaller SiC particle size, even when metallic wires are adhered on spacer surface and connected to high voltage electrode. The DC flashover voltage increases with the decrease of SiC particle size. On the one hand, smaller SiC particle size exhibits more outstanding nonlinear conductivity characteristics, contributing to accelerating charge dissipation, whereas on the other hand, it would introduce plenty of shallow traps due to the increased interfacial regions between SiC particle and epoxy matrix, resulting in aggravating charge accumulation. A theoretical model is proposed to reveal the control mechanism of SiC/epoxy coating with different SiC particle size on flashover performance. The validity of this model can be confirmed based on the surface trap distribution, carrier mobility and our previous investigations on gas–solid interface flashover development process.
Surface flashover properties of alumina/epoxy spacers, involving a surface charge accumulation process, are critical for the safe and reliable operation of a high-voltage direct-current (HVDC) gas-insulated transmission line (GIL). This study reports surface charging behavior and flashover performance of alumina/epoxy spacers with different surface conductivity graded coating (SCGC) schemes in SF 6 /N 2 mixtures under DC stress. Four kinds of SCGC schemes, i.e. localized coating near high voltage (HV-coating), near grounded electrode (GND-coating), at the middle of spacer surface (SPM-coating) and near both high voltage and grounded electrode (HV-GND-coating), are designed by partially spraying SiC/epoxy composites on the spacer surface. Surface charge distribution patterns exhibit varied features with different SCGC schemes. The HV-coating and GND-coating schemes lead to aggravated homo-charge and hetero-charge accumulation respectively, whereas in the SPM-coating scheme surface charge shows a multi-tier distribution pattern with alternating polarity. A transition of the dominant surface charge mechanism from bulk conductivity to surface conductivity with increasing conductivity on the coated area is found. Flashover performance differs a lot with different SCGC schemes: the HV-coating and HV-GND-coating schemes increase the flashover voltage while the SPM-coating and GND-coating schemes degrade it. The optimal surface insulation strength is achieved in the HV-coating scheme with a coating width of about 10 mm. The impact of different SCGC schemes on flashover performance is revealed based on the electric field analysis by considering the effect of surface charges.
1 July 2018 in IET Science, Measurement & Technology
Surface charge accumulation on spacer is an important factor to cause surface flashover. An experimental set‐up is established to measure surface potential over a truncated cone‐type spacer under DC voltage in SF 6 gas at atmospheric pressure using a Kelvin vibrating electrostatic probe. The surface charge density is calibrated based on multipoint measurement technique, which takes the influence of electrostatic probe into account. The experimental results show that surface charge distribution patterns can be divided into three classes including centrosymmetric distribution, spot‐like distribution, and cloud‐like distribution. The symmetrically distributed charges are injected by electrode, which migrate along spacer surface through the surface conductivity. While the charges showing spot‐like and cloud‐like distribution are generated by the ionisation of SF 6 due to local electrical field concentrated. Besides, the hetero‐charges are more easily to be saturated with different charging durations and the polarity of the net charge is the same as that of applied voltage.
Experimental research has shown that much less charge injection occurs in polytetrafluoroethylene (PTFE) compared to polyethylene (PE). To clarify the mechanisms of charge injection from metals into polymer insulators, we comparatively studied charge injection in PE and PTFE oligomers using first-principles calculations. Two different models were studied: chemisorption (bonding) and physisorption (nonbonding). The results show that the electron injection barrier of the metal/PTFE interface is larger than that of the metal/PE interface only in the case of chemisorption. The larger electron injection barrier of the metal/PTFE oligomer interface is mainly affected by the positive vacuum level shift of the metal/PTFE interface induced by electron transfer from the metal to PTFE along the chemical bonds. In the case of physisorption, the hole injection barrier of the metal/PTFE interface is larger than that of the metal/PE interface. This is attributed to the larger ionization potential of PTFE compared to PE. The calculated results reasonably explain the experimental phenomena. The agreement between the experimental and calculated results verifies the rationality of our calculation models. The models used herein can likely be applied in other metal/polymer interfacial systems with acceptable accuracy.