Konstantinos Oureilidis

Dr. Konstantinos Oureilidis

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 September 2015 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
KOKonstantinos Oureilidis
Konstantinos Oureilidis
Charis S. DemouliasCharis S. Demoulias
Charis S. Demoulias
The integration of converter-interfaced distributed generation in microgrids has raised several technical issues, including the successful operation of protective devices during faults. The protection issue is associated with the lack of large current injection during a fault, due to limits imposed by the semiconductor switches. This paper proposes a fault-detection and clearing control strategy method for symmetrical and asymmetrical line faults in a looped microgrid. The protection devices are simple overcurrent devices with the same settings, due to the looped microgrid topology. The proposed method is applied without using any kind of physical communication. The fault is detected by measuring indirectly the microgrid impedance. After the fault identification, the distributed energy resources (DERs) adjust their control in order to inject a current proportional to the measured microgrid impedance, according to a droop curve. This means that the DER closer to the fault injects a relatively larger current, achieving by this way a selective coordination of the protection means. The effectiveness of the proposed control strategy is evaluated through detailed simulation and experimental tests.

18 February 2020 in Energies
Verified
Journal Article
Open access
PDF file
KOKonstantinos Oureilidis
Konstantinos Oureilidis
KMKyriaki-Nefeli D. Malamaki
Kyriaki-Nefeli D. Malamaki
KGKonstantinos Gallos
Konstantinos Gallos
ATAchilleas Tsitsimelis
Achilleas Tsitsimelis
CDChristos Dikaiakos
Christos Dikaiakos
Charis S. DemouliasCharis S. Demoulias
Charis S. Demoulias
The high proliferation of converter-dominated Distributed Renewable Energy Sources (DRESs) at the distribution grid level has gradually replaced the conventional synchronous generators (SGs) of the transmission system, resulting in emerging stability and security challenges. The inherent characteristics of the SGs are currently used for providing ancillary services (ASs), following the instructions of the Transmission System Operator, while the DRESs are obliged to offer specific system support functions, without being remunerated for these functions, but only for the energy they inject. This changing environment has prompted the integration of energy storage systems as a solution for transfusing new characteristics and elaborating their business in the electricity markets, while the smart grid infrastructure and the upcoming microgrid architectures contribute to the transformation of the distribution grid. This review investigates the existing ASs in transmission system with the respective markets (emphasizing the DRESs’ participation in these markets) and proposes new ASs at distribution grid level, with emphasis to inertial response, active power ramp rate control, frequency response, voltage regulation, fault contribution and harmonic mitigation. The market tools and mechanisms for the procurement of these ASs are presented evolving the existing role of the Operators. Finally, potential barriers in the technical, regulatory, and financial framework have been identified and analyzed.

29 January 2018 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
GKGeorgios Kryonidis
Georgios Kryonidis
Eleftherios O. KontisEleftherios O. Kontis
Eleftherios O. Kontis
ACAndreas Chrysochos
Andreas Chrysochos
KOKonstantinos Oureilidis
Konstantinos Oureilidis
Charis S. DemouliasCharis S. Demoulias
Charis S. Demoulias
GPGrigoris Papagiannis
Grigoris Papagiannis
In this letter, a new methodology is proposed to extend the applicability of conventional power flow methods to islanded microgrids (MGs), operating with the droop control method. A slack bus is considered to be connected at a random MG node. The operational conditions of this slack bus as well as of the rest MG nodes are determined through an iterative procedure. The objective of this procedure is to force the active and reactive power flowing through the slack bus to zero, representing the islanded MG operation. The proposed approach has a similar accuracy with time-domain simulations, while it reduces significantly the required computational burden.

16 January 2016 in Journal of Modern Power Systems and Clean Energy
Verified
Journal Article
Open access
PDF file
KOKonstantinos Oureilidis
Konstantinos Oureilidis
EBEmmanouil A. Bakirtzis
Emmanouil A. Bakirtzis
Charis S. DemouliasCharis S. Demoulias
Charis S. Demoulias
When a microgrid is mainly supplied by renewable energy sources (RESs), the frequency deviations may deteriorate significantly the power quality delivered to the loads. This paper proposes a frequency-based control strategy, ensuring the frequency among the strict limits imposed by the Standard EN 50160. The frequency of the microgrid common AC bus is determined by the energy storage converter, implementing a proposed droop curve among the state of charge (SoC) of the battery and the frequency. Therefore, the information of the SoC becomes known to every distributed energy resource (DER) of the microgrid and determines the active power injection of the converter-interfaced DERs. The active power injection of the rotating generators remains unaffected, while any mismatch among the power generation and consumption is absorbed by the energy storage system. Finally, in case of a solid short-circuit within the microgrid, the energy storage system detects the severe voltage decrease and injects a large current in order to clear the fault by activating the protection device closer to the fault. The proposed control methodology is applied in a microgrid with PVs, wind generators and a battery, while its effectiveness is evaluated by detailed simulation tests.

13 October 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Charis S. DemouliasCharis S. Demoulias
Charis S. Demoulias
KMKyriaki-Nefeli D. Malamaki
Kyriaki-Nefeli D. Malamaki
SGSpyros Gkavanoudis
Spyros Gkavanoudis
JMJuan Manuel Mauricio
Juan Manuel Mauricio
GKGeorgios Kryonidis
Georgios Kryonidis
Jose Martinez-RamosJose Martinez-Ramos
Jose Martinez-Ramos
The gradual displacement of synchronous generators driven by conventional power plants, due to the increasing penetration of distributed renewable energy sources (DRES) in distribution grids, is creating a shortage of crucial ancillary services (AS) which are vital for the frequency and voltage stability of the grid. These AS, and some new ones, could now be offered by the DRES, particularly those that are converter interfaced, in a coordinated way in order to preserve the grid stability and resilience. Although recent standards and grid codes specify that the DRES exhibit some system support functions, there are no specifications on how to measure and quantify (M & Q) them both at DRES level and in aggregated form. The M & Q of AS is crucial, since it would allow the AS to be treated as tradable AS in the current and future AS markets. This paper attempts to define a number of AS that can be offered by converter-interfaced DRES and suggests methods for their M & Q. The new AS addressed are: (1) inertial response; (2) primary frequency response; (3) active power smoothing (ramp-rate limitation); (4) exchange of reactive power for voltage regulation; (5) fault-ride-through (FRT) and contribution to fault clearing; (6) voltage harmonic mitigation. Additionally, a rough estimation of the additional investment and operational cost, as well as the financial benefits associated with each AS is provided in order to form the basis for the development of business models around each AS in the near future.

8 December 2020 in IEEE Transactions on Sustainable Energy
Verified
Journal Article
Open access
GKGeorgios Kryonidis
Georgios Kryonidis
KMKyriaki-Nefeli D. Malamaki
Kyriaki-Nefeli D. Malamaki
SGSpyros Gkavanoudis
Spyros Gkavanoudis
KOKonstantinos Oureilidis
Konstantinos Oureilidis
Eleftherios O. KontisEleftherios O. Kontis
Eleftherios O. Kontis
Charis S. DemouliasCharis S. Demoulias
Charis S. Demoulias
This work proposes a new control strategy for the voltage regulation of unbalanced low-voltage (LV) distribution grids with high penetration of distributed renewable energy sources (DRESs). The proposed method uses the available reactive power of DRESs as the primary means for voltage regulation. Furthermore, its distinct feature is the use of a distributed control architecture prioritizing the response of DRESs to maintain the network voltages within permissible limits and minimize the network losses. The prioritization process is locally implemented by each DRES combining two types of information: (a) the sensitivity matrix that quantifies the impact of reactive power variations on the network voltages and (b) voltage measurements along the network. Time-domain and time-series simulations on the IEEE European LV test feeder are performed to evaluate the performance of the proposed method against existing decentralized, distributed and centralized, optimization-based methods.