Elevated cardiac troponin (cTn) showed associations with mortality even in stable patients, but management has not been established. We aimed to investigate whether consultation to cardiologists could reduce mortality of stable patients with cTn elevation at admission. We identified 1329 patients with elevated cTn level at hospitalization from outpatient clinic to any department other than cardiology or cardiac surgery between April 2010 and December 2018. The patients were divided into two groups according to cardiologist consultation at admission. For primary outcome, mortality during one year was compared in the crude and propensity-score-matched populations. In 1329 patients, 397 (29.9%) were consulted to cardiologists and 932 (70.1%) were not. Mortality during the first year was significantly lower in patients consulted to cardiologists compared with those who were not (9.8% vs. 14.2%; hazard ratio (HR), 0.50; 95% confidence interval (CI), 0.35–0.72; p < 0.001). After propensity-score matching, 324 patients were in the cardiologist consultation group and 560 patients were in the no cardiologist consultation group. One-year mortality was consistently lower in the cardiologist consultation group (10.5% vs. 14.6%; HR, 0.58; 95% CI, 0.39–0.86; p = 0.01). Cardiologist consultation may be associated with lower mortality in stable patients with cTn elevation at admission. Further studies are needed to identify effective management strategies for stable patients with elevated cTn.
Background: Pacemakers assist circulation by generating electrical impulses. Patients with pacemakers scheduled to undergo surgery are vulnerable to device-related complications. Therefore, careful perioperative management is required to prevent undesirable events.Case: A 66-year-old man with alcohol-related hepatocellular carcinoma was referred for liver transplantation. The pacemaker was inserted preoperatively to manage sick sinus syndrome and paroxysmal atrial fibrillation. Overall liver transplantation was performed without any adverse events. However, the pacemaker suddenly failed to provide regular pacing rhythm during abdominal closure. Fortunately, the native heart rate was maintained above 70 beats per minute and blood pressure did not fluctuate after pacing failure. After retrospective analysis, the duration setting of preoperative pacemaker reprogramming (24 h) was revealed as the cause of unexpected pacing failure.Conclusions: Anesthesiologists should be alert in patients with pacemakers because minor errors may lead to inadvertent failure of pacing or severe hemodynamic instability.
About Me
Anesthesiologist. Interested in cardiopulmonary anesthesia & molecular biology
Anesthesiologist. Interested in cardiopulmonary anesthesia & molecular biology