Different finite element models of the cervical spine have been suggested for evaluating the roles of ligaments, facet joints, and disks in the stability of cervical spine under sagittal moments. However, no comprehensive study on the response of the full cervical spine that has used a detailed finite element (FE) model (C2-T1) that considers the asymmetry about the mid-sagittal plane has been reported. The aims of this study were to consider asymmetry in a FE model of the full cervical spine and to investigate the influences of ligaments, facet joints, and disk nucleus on the stability of the asymmetric model during flexion and extension. The model was validated against various published in vitro studies and FE studies for the three main loading planes. Next, the C4-C5 level was modified to simulate different cases to investigate the role of the soft tissues in segmental stability. The FE model predicted that excluding the interspinous ligament (ISL) from the index level would cause excessive instability during flexion and that excluding the posterior longitudinal ligament (PLL) or the ligamentum flavum (LF) would not affect segmental rotation. During extension, motion increased when the facet joints were excluded. The model without disk nucleus was unstable compared to the intact model at lower loads and exhibited a similar rotation response at higher loads.
OBJECT: The authors evaluated the biomechanical effects of an interspinous process (ISP) device on kinematics and load sharing at the implanted and adjacent segments. METHODS: A 3D finite-element (FE) model of the lumbar spine (L1–5) was developed and validated through comparison with published in vitro study data. Specifically, validation was achieved by a flexible (load-control) approach in 3 main planes under a pure moment of 10 Nm and a compressive follower load of 400 N. The ISP device was inserted between the L-3 and L-4 processes. Intact and implanted cases were simulated using the hybrid protocol in all motion directions. The resultant motion, facet load, and intradiscal pressure after implantation were investigated at the index and adjacent levels. In addition, stress at the bone-implant interface was predicted. RESULTS: The hybrid approach, shown to be appropriate for adjacent-level investigations, predicted that the ISP device would decrease the range of motion, facet load, and intradiscal pressure at the index level relative to the corresponding values for the intact spine in extension. Specifically, the intradiscal pressure induced after implantation at adjacent segments increased by 39.7% and by 6.6% at L2–3 and L4–5, respectively. Similarly, facet loads at adjacent segments after implantation increased up to 60% relative to the loads in the intact case. Further, the stress at the bone-implant interface increased significantly. The influence of the ISP device on load sharing parameters in motion directions other than extension was negligible. CONCLUSIONS: Although ISP devices apply a distraction force on the processes and prevent further extension of the index segment, their implantation may cause changes in biomechanical parameters such as facet load, intradiscal pressure, and range of motion at adjacent levels in extension.
7 February 2014 in Computer Methods in Biomechanics and Biomedical Engineering
Pedicle screw-based dynamic constructs either benefit from a dynamic (flexible) interconnecting rod or a dynamic (hinged) screw. Both types of systems have been reported in the literature. However, reports where the dynamic system is composed of two dynamic components, i.e. a dynamic (hinged) screw and a dynamic rod, are sparse. In this study, the biomechanical characteristics of a novel pedicle screw-based dynamic stabilisation system were investigated and compared with equivalent rigid and semi-rigid systems using in vitro testing and finite element modelling analysis. All stabilisation systems restored stability after decompression. A significant decrease in the range of motion was observed for the rigid system in all loadings. In the semi-rigid construct the range of motion was significantly less than the intact in extension, lateral bending and axial rotation loadings. There were no significant differences in motion between the intact spine and the spine treated with the dynamic system (P>0.05). The peak stress in screws was decreased when the stabilisation construct was equipped with dynamic rod and/or dynamic screws.
This study compares the clinical and radiological results of three most commonly used dynamic stabilization systems in the field of orthopedic surgery. A total of 71 patients underwent single-level posterior transpedicular dynamic stabilization between 2011 and 2014 due to lumbar degenerative disc disease. Three different dynamic systems used include: (1) the Dynesys system; (2) a dynamic screw with a PEEK rod; and (3) a full dynamic system (a dynamic screw with a dynamic rod; BalanC). The mean patient age was 45.8 years. The mean follow-up was 29.7 months. Clinical and radiological data were obtained for each patient preoperatively and at 6, 12, and 24 months of follow-up. Clinical outcomes were significantly improved in all patients. There were no significant differences in the radiological outcomes among the groups divided according to the system used. Screw loosening was detected in 2 patients, and 1 patient developed screw breakage. All patients with screw loosening or breakage underwent revision surgery. Each procedure offered satisfactory outcome regardless of which system was applied.
10 April 2014 in Journal of Biomechanical Engineering
Currently, rigid fixation systems are the gold standard for degenerative disk disease treatment. Dynamic fixation systems have been proposed as alternatives for the treatment of a variety of spinal disorders. These systems address the main drawbacks of traditional rigid fixation systems, such as adjacent segment degeneration and instrumentation failure. Pedicle-screw-based dynamic stabilization (PDS) is one type of these alternative systems. The aim of this study was to simulate the biomechanical effect of a novel posterior dynamic stabilization system, which is comprised of dynamic (hinged) screws interconnected with a coiled, spring-based dynamic rod (DSDR), and compare it to semirigid (DSRR and RSRR) and rigid stabilization (RSRR) systems. A validated finite element (FE) model of L1-S1 was used to quantify the biomechanical parameters of the spine, such as range of motion, intradiskal pressure, stresses and facet loads after single-level instrumentation with different posterior stabilization systems. The results obtained from in vitro experimental intact and instrumented spines were used to validate the FE model, and the validated model was then used to compare the biomechanical effects of different fixation and stabilization constructs with intact under a hybrid loading protocol. The segmental motion at L4–L5 increased by 9.5% and 16.3% in flexion and left rotation, respectively, in DSDR with respect to the intact spine, whereas it was reduced by 6.4% and 10.9% in extension and left-bending loads, respectively. After instrumentation-induced intradiskal pressure at adjacent segments, L3-L4 and L5-S1 became less than the intact in dynamic rod constructs (DSDR and RSDR) except in the RSDR model in extension where the motion was higher than intact by 9.7% at L3-L4 and 11.3% at L5-S1. The facet loads were insignificant, not exceeding 12N in any of the instrumented cases in flexion. In extension, the facet load in DSDR case was similar to that in intact spine. The dynamic rod constructions (DSDR and RSDR) led to a lesser peak stress at screws compared with rigid rod constructions (DSRR and RSRR) in all loading cases. A dynamic construct consisting of a dynamic rod and a dynamic screw did protect the adjacent level from excessive motion.
1 January 2009 in Australian Journal of Mechanical Engineering
Simulation of the injection stretch blow moulding (ISBM) process for the PET (polyethylene terephthalate) bottle manufacturing process is important in improving quality of PET bottles and reducing production time. This paper presents an investigation of finite element simulation of the ISBM process utilising B-SIM simulation software. For a given perform shape, results are obtained on the effect of various process parameters on wall thickness distribution of PET bottles. On completion of the simulation, the simulated bottle file is exported from B-SIM to ANSYS finite element analysis software for structural analysis. Top load analysis and internal pressure analysis are conducted in verifying the mechanical strength of PET bottles. Results indicate that by proper selection of process parameters and by B-SIM simulation, PET bottles of desired strength can be produced by the injection blow moulding process with more uniform thickness distribution.