Ali Fahir Ozer

Prof. Dr. Ali Fahir Ozer

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2017 in World Neurosurgery
Verified
Journal Article
Closed access
Ali Fahir OzerAli Fahir Ozer
Ali Fahir Ozer
TSTuncer Suzer
Tuncer Suzer
HCHalil Can
Halil Can
MFMani Falsafi
Mani Falsafi
MAMurat Aydin
Murat Aydin
TOTunc Oktenoglu
Tunc Oktenoglu

26 December 2012 in Advances in Orthopedics
Verified
Journal Article
Open access
PDF file
CGCengiz Gomleksiz
Cengiz Gomleksiz
MSMehdi Sasani
Mehdi Sasani
TOTunc Oktenoglu
Tunc Oktenoglu
Ali Fahir OzerAli Fahir Ozer
Ali Fahir Ozer
Interspinous spacers were developed to treat local deformities such as degenerative spondylolisthesis. To treat patients with chronic instability, posterior pedicle fixation and rod-based dynamic stabilization systems were developed as alternatives to fusion surgeries. Dynamic stabilization is the future of spinal surgery, and in the near future, we will be able to see the development of new devices and surgical techniques to stabilize the spine. It is important to follow the development of these technologies and to gain experience using them. In this paper, we review the literature and discuss the dynamic systems, both past and present, used in the market to treat lumbar degeneration.

30 June 2017 in Asian Spine Journal
Verified
Journal Article
Open access
AYAtilla YILMAZ
Atilla YILMAZ
SSSalim Senturk
Salim Senturk
MSMehdi Sasani
Mehdi Sasani
TOTunc Oktenoglu
Tunc Oktenoglu
OYOnur Yaman
Onur Yaman
Ali Fahir OzerAli Fahir Ozer
Ali Fahir Ozer
Study DesignA retrospective study investigating decrease in the nucleus pulposus signal intensity or disc height on magnetic resonance imaging (MRI) and disc degeneration.PurposeAlthough a degenerated disc cannot self-regenerate, distraction or stabilization may provide suitable conditions for rehydration and possible regeneration. This study aimed to evaluate clinical outcomes and disc regeneration via MRI in a series of patients with degenerative disc disease (DDD) who underwent lumbar stabilization with a dynamic stabilization system (DSS).Overview of LiteratureA dynamic system provides rehydration during early DDD.MethodsFifty-nine patients (mean age, 46.5 years) who undedwent stabilization with DSS for segmental instability (painful black disc) between 2004 and 2014 were retrospectively evaluated. All patients underwent MRI preoperatively and 12 months postoperatively. Intervertebral disc (IVD) degeneration grades at the implanted segment were categorized using the Pfirrmann classification system. Patients were followed for a mean of 6.4 years, and clinical outcomes were based on visual analog scale (VAS) and Oswestry disability index (ODI) scores.ResultsSignificant improvements in back pain VAS and ODI scores from before surgery (7 and 68%, respectively) were reported at 6 (2.85 and 27.4%, respectively) and 12 months postoperatively (1.8 and 16.3%, respectively). Postoperative IVD changes were observed in 28 patients. Improvement was observed in 20 patients (34%), whereas progressive degeneration was observed in eight patients (13.5%). Thirty-one patients (52.5%) exhibited neither improvement nor progression. Single Pfirrmann grade improvements were observed in 29% of the patients and two-grade improvements were observed in 5%.ConclusionsOur observations support the theory that physiological movement and a balanced load distribution are necessary for disc regeneration. We conclude that DSS may decelerate the degeneration process and appears to facilitate regeneration.

15 April 2013 in Advances in Orthopedics
Verified
Journal Article
Open access
PDF file
TKTuncay Kaner
Tuncay Kaner
Ali Fahir OzerAli Fahir Ozer
Ali Fahir Ozer
Fusion and rigid instrumentation have been currently the mainstay for the surgical treatment of degenerative diseases of the spine over the last 4 decades. In all over the world the common experience was formed about fusion surgery. Satisfactory results of lumbar spinal fusion appeared completely incompatible and unfavorable within years. Rigid spinal implants along with fusion cause increased stresses of the adjacent segments and have some important disadvantages such as donor site morbidity including pain, wound problems, infections because of longer operating time, pseudarthrosis, and fatigue failure of implants. Alternative spinal implants were developed with time on unsatisfactory outcomes of rigid internal fixation along with fusion. Motion preservation devices which include both anterior and posterior dynamic stabilization are designed and used especially in the last two decades. This paper evaluates the dynamic stabilization of the lumbar spine and talks about chronologically some novel dynamic stabilization devices and thier efficacies.

4 March 2010 in The Open Orthopaedics Journal
Verified
Journal Article
Open access
Ali Fahir OzerAli Fahir Ozer
Ali Fahir Ozer
NCNeil R Crawford
Neil R Crawford
MSMehdi Sasani
Mehdi Sasani
TOTunc Oktenoglu
Tunc Oktenoglu
HBHakan Bozkus
Hakan Bozkus
SASabri Aydin
Sabri Aydin
Background: A lumbar pedicular dynamic stabilization system (LPDSS) is an alternative to fusion for treatment of degenerative disc disease (DDD). In this study, clinical and radiological results of one LPDSS (Saphinaz, Medikon AS, Turkey) were compared with results of rigid fixation after two-year follow-up.Methods: All patients had anteroposterior and lateral standing x-rays of the lumbar spine preoperatively and at 3 months, 12 months and 24 months after surgery. Lordosis of the lumbar spine, segmental lordosis and ratio of the height of the intervertebral disc spaces (IVS) measured preoperatively and at 3 months, 12 months and 24 months after surgery.All patients underwent MRI and/or CT preoperatively, 3months, 12 months and 24 months postoperatively. The ratio of intervertebral disc space to vertebral body height (IVS) and segmental and lumbar lordosis were evaluated preoperatively and postoperatively. Pain scores were evaluatedviaVisual Analog Scale (VAS) and Oswestry Disability Index (ODI) preoperatively and postoperatively.Results: In both groups, the VAS and ODI scores decreased significantly from preoperatively to postoperatively. There was no difference in the scores between groups except that a lower VAS and ODI scores were observed after 3 months in the LPDSS group. In both groups, the IVS ratio remained unchanged between preoperative and postoperative conditions. The lumbar and segmental lordotic angles decreased insignificantly to preoperative levels in the months following surgery.Conclusions: Patients with LPDSS had equivalent relief of pain and maintenance of sagittal balance to patients with standard rigid screw-rod fixation. LPDSS appears to be a good alternative to rigid fixation.

1 January 2017 in Clinics in Orthopedic Surgery
Verified
Journal Article
Open access
Ali Fahir OzerAli Fahir Ozer
Ali Fahir Ozer
TOTunc Oktenoglu
Tunc Oktenoglu
EEEmrah EGEMEN
Emrah EGEMEN
MSMehdi Sasani
Mehdi Sasani
AYAtilla YILMAZ
Atilla YILMAZ
TSTuncer Suzer
Tuncer Suzer
This study compares the clinical and radiological results of three most commonly used dynamic stabilization systems in the field of orthopedic surgery. A total of 71 patients underwent single-level posterior transpedicular dynamic stabilization between 2011 and 2014 due to lumbar degenerative disc disease. Three different dynamic systems used include: (1) the Dynesys system; (2) a dynamic screw with a PEEK rod; and (3) a full dynamic system (a dynamic screw with a dynamic rod; BalanC). The mean patient age was 45.8 years. The mean follow-up was 29.7 months. Clinical and radiological data were obtained for each patient preoperatively and at 6, 12, and 24 months of follow-up. Clinical outcomes were significantly improved in all patients. There were no significant differences in the radiological outcomes among the groups divided according to the system used. Screw loosening was detected in 2 patients, and 1 patient developed screw breakage. All patients with screw loosening or breakage underwent revision surgery. Each procedure offered satisfactory outcome regardless of which system was applied.