Matteo Mario Carlà

Dr. Matteo Mario Carlà

Università Cattolica del Sacro Cuore, Rome, Lazio, Italy
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 March 2024 in British Journal of Ophthalmology
Verified
Journal Article
Closed access
PDF file
MCMatteo Mario Carlà
Matteo Mario Carlà
GGGloria Gambini
Gloria Gambini
ABAntonio Baldascino
Antonio Baldascino
FGFederico Giannuzzi
Federico Giannuzzi
FBFrancesco Boselli
Francesco Boselli
Stanislao RizzoStanislao Rizzo
Stanislao Rizzo
Background We aimed to define the capability of three different publicly available large language models, Chat Generative Pretrained Transformer (ChatGPT-3.5), ChatGPT-4 and Google Gemini in analysing retinal detachment cases and suggesting the best possible surgical planning. Methods Analysis of 54 retinal detachments records entered into ChatGPT and Gemini’s interfaces. After asking ‘Specify what kind of surgical planning you would suggest and the eventual intraocular tamponade.’ and collecting the given answers, we assessed the level of agreement with the common opinion of three expert vitreoretinal surgeons. Moreover, ChatGPT and Gemini answers were graded 1–5 (from poor to excellent quality), according to the Global Quality Score (GQS). Results After excluding 4 controversial cases, 50 cases were included. Overall, ChatGPT-3.5, ChatGPT-4 and Google Gemini surgical choices agreed with those of vitreoretinal surgeons in 40/50 (80%), 42/50 (84%) and 35/50 (70%) of cases. Google Gemini was not able to respond in five cases. Contingency analysis showed significant differences between ChatGPT-4 and Gemini (p=0.03). ChatGPT’s GQS were 3.9±0.8 and 4.2±0.7 for versions 3.5 and 4, while Gemini scored 3.5±1.1. There was no statistical difference between the two ChatGPTs (p=0.22), while both outperformed Gemini scores (p=0.03 and p=0.002, respectively). The main source of error was endotamponade choice (14% for ChatGPT-3.5 and 4, and 12% for Google Gemini). Only ChatGPT-4 was able to suggest a combined phacovitrectomy approach. Conclusion In conclusion, Google Gemini and ChatGPT evaluated vitreoretinal patients’ records in a coherent manner, showing a good level of agreement with expert surgeons. According to the GQS, ChatGPT’s recommendations were much more accurate and precise.

4 April 2024 in Graefe's Archive for Clinical and Experimental Ophthalmology
Verified
Journal Article
Open access
PDF file
MCMatteo Mario Carlà
Matteo Mario Carlà
GGGloria Gambini
Gloria Gambini
ABAntonio Baldascino
Antonio Baldascino
FBFrancesco Boselli
Francesco Boselli
FGFederico Giannuzzi
Federico Giannuzzi
SRStanislao Rizzo
Stanislao Rizzo
Purpose: The aim of this study was to define the capability of ChatGPT-4 and Google Gemini in analyzing detailed glaucoma case descriptions and suggesting an accurate surgical plan. Methods: Retrospective analysis of 60 medical records of surgical glaucoma was divided into “ordinary” (n = 40) and “challenging” (n = 20) scenarios. Case descriptions were entered into ChatGPT and Bard’s interfaces with the question “What kind of surgery would you perform?” and repeated three times to analyze the answers’ consistency. After collecting the answers, we assessed the level of agreement with the unified opinion of three glaucoma surgeons. Moreover, we graded the quality of the responses with scores from 1 (poor quality) to 5 (excellent quality), according to the Global Quality Score (GQS) and compared the results. Results: ChatGPT surgical choice was consistent with those of glaucoma specialists in 35/60 cases (58%), compared to 19/60 (32%) of Gemini (p = 0.0001). Gemini was not able to complete the task in 16 cases (27%). Trabeculectomy was the most frequent choice for both chatbots (53% and 50% for ChatGPT and Gemini, respectively). In “challenging” cases, ChatGPT agreed with specialists in 9/20 choices (45%), outperforming Google Gemini performances (4/20, 20%). Overall, GQS scores were 3.5 ± 1.2 and 2.1 ± 1.5 for ChatGPT and Gemini (p = 0.002). This difference was even more marked if focusing only on “challenging” cases (1.5 ± 1.4 vs. 3.0 ± 1.5, p = 0.001). Conclusion: ChatGPT-4 showed a good analysis performance for glaucoma surgical cases, either ordinary or challenging. On the other side, Google Gemini showed strong limitations in this setting, presenting high rates of unprecise or missed answers.

9 February 2022 in Vision
Verified
Journal Article
Open access
PDF file
GGGloria Gambini
Gloria Gambini
MCMatteo Mario Carlà
Matteo Mario Carlà
FGFederico Giannuzzi
Federico Giannuzzi
TCTomaso Caporossi
Tomaso Caporossi
UVUmberto De Vico
Umberto De Vico
Stanislao RizzoStanislao Rizzo
Stanislao Rizzo
For moderate-to-severe glaucoma, trabeculectomy remains the “gold standard” intraocular pressure (IOP)-lowering treatment; nonetheless, this method requires extensive post-operative maintenance. Microinvasive glaucoma surgery (MIGS) treatments are designed to lessen intra- and post-operative care burden while offering an acceptable IOP decrease for individuals with mild to moderate glaucoma. The PreserFlo® MicroShunt (previously InnFocus MicroShunt) is an 8.5 mm glaucoma drainage device manufactured from poly(styrene-block-isobutylene-block-styrene) (SIBS), an extremely biocompatible and bioinert material. The lumen is narrow enough to prevent hypotony, but big enough to avoid being obstructed by sloughed cells or pigment. The device is implanted ab externo, as a stand-alone procedure or in conjunction with cataract surgery, with intraoperative mitomycin C, and a bleb is produced under the conjunctiva and Tenon’s capsule. The MicroShunt was CE-marked in 2012 and designed for primary open-angle glaucoma, the IOP of which remains uncontrolled after maximally tolerated topical treatment. Several clinical trials evaluating the MicroShunt’s long-term safety and effectiveness have been conducted, highlighting the effectiveness of the device over time, along with a tolerable safety profile. The present review aims to gather evidence of PreserFlo’s effectiveness and safety results almost 10 years after its introduction, and furthermore, to compare it with other MIGS and with the gold-standard trabeculectomy for glaucoma management.

2 April 2022 in Vision
Verified
Journal Article
Open access
PDF file
MCMatteo Mario Carlà
Matteo Mario Carlà
FBFrancesco Boselli
Francesco Boselli
FGFederico Giannuzzi
Federico Giannuzzi
GGGloria Gambini
Gloria Gambini
TCTomaso Caporossi
Tomaso Caporossi
Stanislao RizzoStanislao Rizzo
Stanislao Rizzo
Myopia is becoming more common across the world, affecting approximately two billion people and rising. Different kinds of therapies (optical, pharmaceutical, environmental, or behavioral) have been proposed to decrease myopia progression, but with variable results and a lack of standardization. The evidence that targeted myopic defocus inhibits eye length growth has paved the way for several contact and spectacle lense designs to induce a peripheral defocus, thus slowing myopia progression, but the perfect configuration has yet to be defined. One of the newest and more promising approaches in this field is the use of Defocus Incorporated Multiple Segments (DIMS) lenses. These lenses are built from the assumption that targeted myopic defocus, produced by 396 mid-peripheral lenslets with positive power, inhibits eye length growth. Recent studies have highlighted the effectiveness of these lenses compared to children who had worn single vision spectacle lenses, in terms of myopia control and tolerability. Despite the evidence that these lenses can help slow down the progression of myopia, the occasional mid-peripheral aberrations they can induce, as well as the overall eye strain that comes with wearing them, should not be overlooked. The aim of this review is to give attention to the advantages and the shortfalls of this new approach and to evaluate its effectiveness in clinical practice.

28 May 2025 in Graefe's Archive for Clinical and Experimental Ophthalmology
Verified
Journal Article
Open access
PDF file
MCMatteo Mario Carlà
Matteo Mario Carlà
GGGloria Gambini
Gloria Gambini
FBFrancesco Boselli
Francesco Boselli
LHLorenzo Hu
Lorenzo Hu
APAgnese Maria Perugini
Agnese Maria Perugini
SRStanislao Rizzo
Stanislao Rizzo
Purpose: The Paul Glaucoma Implant (PGI) is a novel non-valved glaucoma drainage device designed to lower intraocular pressure (IOP) in patients with refractory glaucoma. This systematic review aims to evaluate the current evidence on safety, efficacy, and emerging applications of PGI implantation. Methods: A systematic literature search was conducted following PRISMA guidelines across PubMed/Medline, Embase, Cochrane, Google Scholar, and Web of Science databases up to April 2025. Quality assessment was performed using the NIH Quality Assessment Tool for Before-After Studies. Data on patient demographics, surgical techniques, IOP outcomes, success rates, and complications were extracted and analyzed. Results: Eighteen studies (946 eyes) met the inclusion criteria. The PGI consistently demonstrated significant IOP reduction across various studies and glaucoma subtypes. Mean IOP reductions ranged from 14.8 mmHg to 19.1 mmHg, depending on follow-up duration and patient characteristics. Complete success rates ranged from 38.4% to 75%, while qualified success rates were consistently high, reaching up to 93.2%. The PGI's unique design, featuring a smaller inner tube diameter (0.127 mm), is thought to contribute to a lower risk of hypotony compared to other non-valved implants. Three comparative studies with other GDDs reported similar success rates with potentially fewer early complications. Quality assessment revealed moderate-to-good quality evidence, with limitations including short follow-up periods and predominance of uncontrolled studies. Conclusions: The PGI is emerging as a safe and effective surgical option for treating refractory glaucoma. Its smaller tube diameter and large surface area endplate contribute to efficient IOP control with a potentially lower risk of hypotony.

17 May 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
GGGloria Gambini
Gloria Gambini
MCMatteo Mario Carlà
Matteo Mario Carlà
FGFederico Giannuzzi
Federico Giannuzzi
FBFrancesco Boselli
Francesco Boselli
GGGiulia Grieco
Giulia Grieco
Stanislao RizzoStanislao Rizzo
Stanislao Rizzo
Background: The purpose of this study is to compare the morphology of six-month follow-up blebs created by a subconjunctival glaucoma surgical device (XEN45) to those created by a PreserFlo MicroShunt with a sub-Tenon insertion, utilizing AS-OCT. Methods: A retrospective study of 29 eyes who underwent XEN45 implantation and 29 eyes who underwent PreserFlo MicroShunt implantation. The patients were analyzed at 24 h, 1 week, 1 month, 3 months and 6 months. At each visit, the maturation and morphological alterations of the blebs were observed, as well as connections with the IOP. Results: In both groups, IOP showed significant reduction at all follow ups (p < 0.0001). In XEN group, the most common bleb morphology in the immediate postoperative was the subconjuntival separation type (42%) followed by the uniform type (34%), with a trend inversion at 6 month follow up (51% of uniform type). On the contrary, the most common morphology after PreserFlo was the multiple internal layer (55%), which showed a tendency to reduce over time and was substituted by the microcystic multiform, whose percentage increased over time (17% at day 1 vs. 44% at month 6). Uniform appearance was associated by the posterior episcleral fluid (PEF) lake presence. Both horizontal and vertical diameters significantly increased over time. Conclusion: XEN and PreserFlo implantation resulted in the production of diffuse blebs with different characteristics, which may influence IOP lowering capacity and bleb revisions necessity over time.