Federico Giannuzzi

Dr. Federico Giannuzzi

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 February 2022 in Vision
Verified
Journal Article
Open access
PDF file
GGGloria Gambini
Gloria Gambini
MCMatteo Mario Carlà
Matteo Mario Carlà
FGFederico Giannuzzi
Federico Giannuzzi
TCTomaso Caporossi
Tomaso Caporossi
UVUmberto De Vico
Umberto De Vico
Stanislao RizzoStanislao Rizzo
Stanislao Rizzo
For moderate-to-severe glaucoma, trabeculectomy remains the “gold standard” intraocular pressure (IOP)-lowering treatment; nonetheless, this method requires extensive post-operative maintenance. Microinvasive glaucoma surgery (MIGS) treatments are designed to lessen intra- and post-operative care burden while offering an acceptable IOP decrease for individuals with mild to moderate glaucoma. The PreserFlo® MicroShunt (previously InnFocus MicroShunt) is an 8.5 mm glaucoma drainage device manufactured from poly(styrene-block-isobutylene-block-styrene) (SIBS), an extremely biocompatible and bioinert material. The lumen is narrow enough to prevent hypotony, but big enough to avoid being obstructed by sloughed cells or pigment. The device is implanted ab externo, as a stand-alone procedure or in conjunction with cataract surgery, with intraoperative mitomycin C, and a bleb is produced under the conjunctiva and Tenon’s capsule. The MicroShunt was CE-marked in 2012 and designed for primary open-angle glaucoma, the IOP of which remains uncontrolled after maximally tolerated topical treatment. Several clinical trials evaluating the MicroShunt’s long-term safety and effectiveness have been conducted, highlighting the effectiveness of the device over time, along with a tolerable safety profile. The present review aims to gather evidence of PreserFlo’s effectiveness and safety results almost 10 years after its introduction, and furthermore, to compare it with other MIGS and with the gold-standard trabeculectomy for glaucoma management.

2 April 2022 in Vision
Verified
Journal Article
Open access
PDF file
MCMatteo Mario Carlà
Matteo Mario Carlà
FBFrancesco Boselli
Francesco Boselli
FGFederico Giannuzzi
Federico Giannuzzi
GGGloria Gambini
Gloria Gambini
TCTomaso Caporossi
Tomaso Caporossi
Stanislao RizzoStanislao Rizzo
Stanislao Rizzo
Myopia is becoming more common across the world, affecting approximately two billion people and rising. Different kinds of therapies (optical, pharmaceutical, environmental, or behavioral) have been proposed to decrease myopia progression, but with variable results and a lack of standardization. The evidence that targeted myopic defocus inhibits eye length growth has paved the way for several contact and spectacle lense designs to induce a peripheral defocus, thus slowing myopia progression, but the perfect configuration has yet to be defined. One of the newest and more promising approaches in this field is the use of Defocus Incorporated Multiple Segments (DIMS) lenses. These lenses are built from the assumption that targeted myopic defocus, produced by 396 mid-peripheral lenslets with positive power, inhibits eye length growth. Recent studies have highlighted the effectiveness of these lenses compared to children who had worn single vision spectacle lenses, in terms of myopia control and tolerability. Despite the evidence that these lenses can help slow down the progression of myopia, the occasional mid-peripheral aberrations they can induce, as well as the overall eye strain that comes with wearing them, should not be overlooked. The aim of this review is to give attention to the advantages and the shortfalls of this new approach and to evaluate its effectiveness in clinical practice.

17 May 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
GGGloria Gambini
Gloria Gambini
MCMatteo Mario Carlà
Matteo Mario Carlà
FGFederico Giannuzzi
Federico Giannuzzi
FBFrancesco Boselli
Francesco Boselli
GGGiulia Grieco
Giulia Grieco
Stanislao RizzoStanislao Rizzo
Stanislao Rizzo
Background: The purpose of this study is to compare the morphology of six-month follow-up blebs created by a subconjunctival glaucoma surgical device (XEN45) to those created by a PreserFlo MicroShunt with a sub-Tenon insertion, utilizing AS-OCT. Methods: A retrospective study of 29 eyes who underwent XEN45 implantation and 29 eyes who underwent PreserFlo MicroShunt implantation. The patients were analyzed at 24 h, 1 week, 1 month, 3 months and 6 months. At each visit, the maturation and morphological alterations of the blebs were observed, as well as connections with the IOP. Results: In both groups, IOP showed significant reduction at all follow ups (p < 0.0001). In XEN group, the most common bleb morphology in the immediate postoperative was the subconjuntival separation type (42%) followed by the uniform type (34%), with a trend inversion at 6 month follow up (51% of uniform type). On the contrary, the most common morphology after PreserFlo was the multiple internal layer (55%), which showed a tendency to reduce over time and was substituted by the microcystic multiform, whose percentage increased over time (17% at day 1 vs. 44% at month 6). Uniform appearance was associated by the posterior episcleral fluid (PEF) lake presence. Both horizontal and vertical diameters significantly increased over time. Conclusion: XEN and PreserFlo implantation resulted in the production of diffuse blebs with different characteristics, which may influence IOP lowering capacity and bleb revisions necessity over time.

Verified
Journal Article
Open access
PDF file
GGGloria Gambini
Gloria Gambini
LSLuca Scartozzi
Luca Scartozzi
FGFederico Giannuzzi
Federico Giannuzzi
MCMatteo Mario Carlà
Matteo Mario Carlà
FBFrancesco Boselli
Francesco Boselli
SRStanislao Rizzo
Stanislao Rizzo
Fabry disease (FD) is an X-linked lysosomal storage disorder, causing Gb-3 (globotriaosylceramide) buildup in cellular lysosomes throughout the body, in particular in blood vessel walls, neuronal cells, and smooth muscle. The gradual accumulation of this glycosphingolipid in numerous eye tissues causes conjunctival vascular abnormalities, corneal epithelial opacities (cornea verticillata), lens opacities, and retinal vascular abnormalities. Although a severe vision impairment is rare, these abnormalities are diagnostic indicators and prognostics for severity. Cornea verticillata is the most common ophthalmic feature in both hemizygous men and heterozygous females. Vessel tortuosity has been linked to a faster disease progression and may be useful in predicting systemic involvement. New technologies such as optical coherence tomography angiography (OCTA) are useful for monitoring retinal microvasculature alterations in FD patients. Along with OCTA, corneal topographic analysis, confocal microscopy, and electro-functional examinations, contributed to the recognition of ocular abnormalities and have been correlated with systemic involvement. We offer an update regarding FD ocular manifestations, focusing on findings derived from the most recent imaging modalities, to optimize the management of this pathology.

17 March 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
MCMatteo Mario Carlà
Matteo Mario Carlà
FBFrancesco Boselli
Francesco Boselli
FGFederico Giannuzzi
Federico Giannuzzi
GGGloria Gambini
Gloria Gambini
TCTomaso Caporossi
Tomaso Caporossi
Stanislao RizzoStanislao Rizzo
Stanislao Rizzo
Intraoperative optical coherence tomography (iOCT) is a noninvasive imaging technique that gives real-time dynamic feedback on surgical procedures. iOCT was first employed in vitreoretinal surgery, but successively served as a guidance in several anterior segment surgical approaches: keratoplasty, implantable Collamer lens (ICL) implantation, and cataract surgery. Among all of those approaches, the unbeatable features of iOCT are fully exploited in anterior and posterior lamellar keratoplasty, and the purpose of this review is to focus on the advantages and shortfalls of iOCT in these techniques, in order to assess whether this technology could be a real step forward. In deep anterior lamellar keratoplasty (DALK), iOCT is useful to evaluate the needle depth into the corneal stroma, the big bubble dissection plane, and residual stromal bed, thus aiding the standardization of the technique and the reduction of failures. In Descemet stripping automated endothelial keratoplasty (DSAEK), iOCT allowed for clear visibility of fluid at the graft/host interface, allowing for immediate rescue maneuvers and granting the best graft apposition. In Descemet membrane endothelial keratoplasty (DMEK), iOCT can track the lenticule unfolding in real time and assess graft orientation even in severe hazy corneas, thus optimizing surgical times, as well as avoiding the use of potentially hazardous exterior markers (such as the “S” stamp) and preventing unnecessary manipulation of the graft. Overall, the role of iOCT appeared crucial in several complicated cases, overcoming the difficulties of poor visualization in a fast, non-invasive way, thus raising this approach as possible gold standard for challenging conditions. Further improvements in the technology may enable autonomous centering and tracking, overcoming the current constraint of instrument-induced shadowing.

27 April 2023 in Journal of Robotic Surgery
Verified
Journal Article
Open access
PDF file
FMFernando Molle
Fernando Molle
MSMaria Cristina Savastano
Maria Cristina Savastano
FGFederico Giannuzzi
Federico Giannuzzi
CFClaudia Fossataro
Claudia Fossataro
DBDavide Brando
Davide Brando
SRStanislao Rizzo
Stanislao Rizzo
Da Vinci three-dimensional (3D) system has been increasingly used in customary surgical settings, gaining fundamental relevance for abdominal, urological, and gynecological laparoscopic surgery. The aim of this research is to evaluate the degree of discomfort and potential changes in the binocular vision and ocular motility of surgical operators, who employ 3D vision systems during Da Vinci robotic surgery. Twenty-four surgeons were enrolled in the study, including twelve who typically use the 3D Da Vinci system and twelve who routinely employ 2D system. Routine general ophthalmological and orthoptic examinations were conducted at baseline (T0), the day before surgery, and 30 min after the 3D or 2D surgery (T1). In addition, surgeons were interviewed using a questionnaire of 18 symptoms, with each item containing three questions regarding the frequency, severity, and bothersomeness of the symptoms, in order to evaluate the degree of discomfort. Mean age at evaluation was 45.28 ± 8.71 years (range 33–63 years). Cover test, uncover test, and fusional amplitude showed no statistically significant difference. After surgery, no statistical difference was observed in the Da Vinci group on the TNO stereotest (p > 0.9999). However, the difference in the 2D group resulted statistically significant (p = 0.0156). Comparing participants (p 0.0001) and time (T0–T1; p = 0.0137), the difference between the two groups was statistically significant. Surgeons using 2D systems reported more discomfort than those using 3D systems. The absence of short-term consequences following surgery with the Da Vinci 3D system is a promising conclusion, considering the numerous advantages of this technology. Nonetheless, multicenter investigations and more studies are required to verify and interpret our findings.