Gloria Gambini

Dr. Gloria Gambini


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 March 2024 in British Journal of Ophthalmology
Verified
Journal Article
Closed access
PDF file
MCMatteo Mario Carlà
Matteo Mario Carlà
GGGloria Gambini
Gloria Gambini
ABAntonio Baldascino
Antonio Baldascino
FGFederico Giannuzzi
Federico Giannuzzi
FBFrancesco Boselli
Francesco Boselli
Stanislao RizzoStanislao Rizzo
Stanislao Rizzo
Background We aimed to define the capability of three different publicly available large language models, Chat Generative Pretrained Transformer (ChatGPT-3.5), ChatGPT-4 and Google Gemini in analysing retinal detachment cases and suggesting the best possible surgical planning. Methods Analysis of 54 retinal detachments records entered into ChatGPT and Gemini’s interfaces. After asking ‘Specify what kind of surgical planning you would suggest and the eventual intraocular tamponade.’ and collecting the given answers, we assessed the level of agreement with the common opinion of three expert vitreoretinal surgeons. Moreover, ChatGPT and Gemini answers were graded 1–5 (from poor to excellent quality), according to the Global Quality Score (GQS). Results After excluding 4 controversial cases, 50 cases were included. Overall, ChatGPT-3.5, ChatGPT-4 and Google Gemini surgical choices agreed with those of vitreoretinal surgeons in 40/50 (80%), 42/50 (84%) and 35/50 (70%) of cases. Google Gemini was not able to respond in five cases. Contingency analysis showed significant differences between ChatGPT-4 and Gemini (p=0.03). ChatGPT’s GQS were 3.9±0.8 and 4.2±0.7 for versions 3.5 and 4, while Gemini scored 3.5±1.1. There was no statistical difference between the two ChatGPTs (p=0.22), while both outperformed Gemini scores (p=0.03 and p=0.002, respectively). The main source of error was endotamponade choice (14% for ChatGPT-3.5 and 4, and 12% for Google Gemini). Only ChatGPT-4 was able to suggest a combined phacovitrectomy approach. Conclusion In conclusion, Google Gemini and ChatGPT evaluated vitreoretinal patients’ records in a coherent manner, showing a good level of agreement with expert surgeons. According to the GQS, ChatGPT’s recommendations were much more accurate and precise.

8 September 2020 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
ASAlfonso Savastano
Alfonso Savastano
ECEmanuele crincoli
Emanuele crincoli
MSMaria Cristina Savastano
Maria Cristina Savastano
SYSaad Younis
Saad Younis
GGGloria Gambini
Gloria Gambini
GGGemelli Against COVID-19 Post-Acute Care Study Group
Gemelli Against COVID-19 Post-Acute Care Study Group
The ability of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2′s) to cause multi-organ ischemia and coronavirus-induced posterior segment eye diseases in mammals gave concern about potential sight-threatening ischemia in post coronavirus disease 2019 patients. The radial peripapillary capillary plexus (RPCP) is a sensitive target due to the important role in the vascular supply of the peripapillary retinal nerve fiber layer (RNFL). Eighty patients one month after SARS-CoV-2 infection and 30 healthy patients were selected to undergo structural OCT (optical coherence tomography) and OCTA (optical coherence tomography angiography) exams. Primary outcome was a difference in RPCP perfusion density (RPCP-PD) and RPCP flow index (RPCP-FI). No significant difference was observed in age, sex, intraocular pressure (IOP) and prevalence of myopia. RPCP-PD was lower in post SARS-CoV-2 patients compared to controls. Within the post-COVID-19 group, patients with systemic arterial hypertension had lower RPCP-FI and age was inversely correlated to both RPCP-FI and RPCP-PD. Patients treated with lopinavir + ritonavir or antiplatelet therapy during admission had lower RPCP-FI and RPCP-PD. RNFL average thickness was linearly correlated to RPCP-FI and RPCP-PD within post-COVID-19 group. Future studies will be needed to address the hypothesis of a microvascular retinal impairment in individuals who recovered from SARS-CoV-2 infection.

9 February 2022 in Vision
Verified
Journal Article
Open access
PDF file
GGGloria Gambini
Gloria Gambini
MCMatteo Mario Carlà
Matteo Mario Carlà
FGFederico Giannuzzi
Federico Giannuzzi
TCTomaso Caporossi
Tomaso Caporossi
UVUmberto De Vico
Umberto De Vico
Stanislao RizzoStanislao Rizzo
Stanislao Rizzo
For moderate-to-severe glaucoma, trabeculectomy remains the “gold standard” intraocular pressure (IOP)-lowering treatment; nonetheless, this method requires extensive post-operative maintenance. Microinvasive glaucoma surgery (MIGS) treatments are designed to lessen intra- and post-operative care burden while offering an acceptable IOP decrease for individuals with mild to moderate glaucoma. The PreserFlo® MicroShunt (previously InnFocus MicroShunt) is an 8.5 mm glaucoma drainage device manufactured from poly(styrene-block-isobutylene-block-styrene) (SIBS), an extremely biocompatible and bioinert material. The lumen is narrow enough to prevent hypotony, but big enough to avoid being obstructed by sloughed cells or pigment. The device is implanted ab externo, as a stand-alone procedure or in conjunction with cataract surgery, with intraoperative mitomycin C, and a bleb is produced under the conjunctiva and Tenon’s capsule. The MicroShunt was CE-marked in 2012 and designed for primary open-angle glaucoma, the IOP of which remains uncontrolled after maximally tolerated topical treatment. Several clinical trials evaluating the MicroShunt’s long-term safety and effectiveness have been conducted, highlighting the effectiveness of the device over time, along with a tolerable safety profile. The present review aims to gather evidence of PreserFlo’s effectiveness and safety results almost 10 years after its introduction, and furthermore, to compare it with other MIGS and with the gold-standard trabeculectomy for glaucoma management.

21 December 2020 in Cornea
Verified
Journal Article
Closed access
GGGloria Gambini
Gloria Gambini
MSMaria Cristina Savastano
Maria Cristina Savastano
ASAlfonso Savastano
Alfonso Savastano
UVUmberto De Vico
Umberto De Vico
ECEmanuele Crincoli
Emanuele Crincoli
SRStanislao Rizzo
Stanislao Rizzo
Purpose: This is a cohort study to evaluate the presence of objective signs and subjective symptoms of dry eye disease in postcoronavirus disease 2019 (COVID-19) patients compared with the control. Methods: Prospective, observational, single-ctenter, cohort study. Sixty-four post-COVID-19 patients and 50 control were recruited. All participants underwent a complete ophthalmological examination including Ocular Surface Disease Index Questionnaire (OSDI), best-corrected visual acuity, slit-lamp biomicroscopy, fundus examination, Schirmer test type 1, tear break-up time test (tBUT), evaluation of conjunctival hyperemia, corneal staining, and tear film osmolarity test. Results: The OSDI score was higher in the post-COVID-19 group in the quantitative and qualitative analysis (P < 0.001 and P =0.012, respectively). The mean tBUT in post-COVID-19 patients was 6.95 ± 4.07 seconds compared with a mean tBUT of 10.12 ± 3.90 seconds in the control group. The post-COVID-19 group showed a higher number of patients with a simultaneous impairment of the OSDI score and tBUT (P = 0.019). The Schirmer test results were strikingly significant both in the quantitative analysis and qualitative analysis (P <0.001 and P = 0.0014, respectively). Both quantitative analysis and qualitative analysis revealed a significant difference in tear osmolarity in the 2 groups. Conclusions: Comparing the ocular surface assessment of post-COVID-19 patients with heathy control, a statistically significant increase of dry eye disease has emerged both in subjective and objective evaluations. Our clinical results support the findings that suggested a susceptibility of the ocular surface to the virus, and it underlines the importance of the ocular surface assessment in post-COVID-19 patients for a correct diagnosis and therapy.

2 April 2022 in Vision
Verified
Journal Article
Open access
PDF file
MCMatteo Mario Carlà
Matteo Mario Carlà
FBFrancesco Boselli
Francesco Boselli
FGFederico Giannuzzi
Federico Giannuzzi
GGGloria Gambini
Gloria Gambini
TCTomaso Caporossi
Tomaso Caporossi
Stanislao RizzoStanislao Rizzo
Stanislao Rizzo
Myopia is becoming more common across the world, affecting approximately two billion people and rising. Different kinds of therapies (optical, pharmaceutical, environmental, or behavioral) have been proposed to decrease myopia progression, but with variable results and a lack of standardization. The evidence that targeted myopic defocus inhibits eye length growth has paved the way for several contact and spectacle lense designs to induce a peripheral defocus, thus slowing myopia progression, but the perfect configuration has yet to be defined. One of the newest and more promising approaches in this field is the use of Defocus Incorporated Multiple Segments (DIMS) lenses. These lenses are built from the assumption that targeted myopic defocus, produced by 396 mid-peripheral lenslets with positive power, inhibits eye length growth. Recent studies have highlighted the effectiveness of these lenses compared to children who had worn single vision spectacle lenses, in terms of myopia control and tolerability. Despite the evidence that these lenses can help slow down the progression of myopia, the occasional mid-peripheral aberrations they can induce, as well as the overall eye strain that comes with wearing them, should not be overlooked. The aim of this review is to give attention to the advantages and the shortfalls of this new approach and to evaluate its effectiveness in clinical practice.

17 May 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
GGGloria Gambini
Gloria Gambini
MCMatteo Mario Carlà
Matteo Mario Carlà
FGFederico Giannuzzi
Federico Giannuzzi
FBFrancesco Boselli
Francesco Boselli
GGGiulia Grieco
Giulia Grieco
Stanislao RizzoStanislao Rizzo
Stanislao Rizzo
Background: The purpose of this study is to compare the morphology of six-month follow-up blebs created by a subconjunctival glaucoma surgical device (XEN45) to those created by a PreserFlo MicroShunt with a sub-Tenon insertion, utilizing AS-OCT. Methods: A retrospective study of 29 eyes who underwent XEN45 implantation and 29 eyes who underwent PreserFlo MicroShunt implantation. The patients were analyzed at 24 h, 1 week, 1 month, 3 months and 6 months. At each visit, the maturation and morphological alterations of the blebs were observed, as well as connections with the IOP. Results: In both groups, IOP showed significant reduction at all follow ups (p < 0.0001). In XEN group, the most common bleb morphology in the immediate postoperative was the subconjuntival separation type (42%) followed by the uniform type (34%), with a trend inversion at 6 month follow up (51% of uniform type). On the contrary, the most common morphology after PreserFlo was the multiple internal layer (55%), which showed a tendency to reduce over time and was substituted by the microcystic multiform, whose percentage increased over time (17% at day 1 vs. 44% at month 6). Uniform appearance was associated by the posterior episcleral fluid (PEF) lake presence. Both horizontal and vertical diameters significantly increased over time. Conclusion: XEN and PreserFlo implantation resulted in the production of diffuse blebs with different characteristics, which may influence IOP lowering capacity and bleb revisions necessity over time.