Zhibin Ling

Zhibin Ling


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 February 2022 in Materials
Verified
Journal Article
Open access
PDF file
Henan ZhangHenan Zhang
Henan Zhang
Zhibin LingZhibin Ling
Zhibin Ling
Steel–timber composite (STC) systems are considered as an environmentally friendly alternative to steel–concrete composite (SCC) structures due to its advantages including high strength-to-weight ratio, lower carbon footprint, and fully dry construction. Bolts and screws are the most commonly used connectors in STC system; however, they probably make great demands on the accuracy of construction because of the predrilling in both the timber slabs and steel girder fangles. To address this issue, the STC connections with grouted stud connectors (GSC) were proposed in this paper. In addition, stud connectors can also provide outstanding stiffness and load-bearing capacity. The mechanical characteristic of the GSC connections was exploratorily investigated by finite element (FE) modeling. The designed parameters for the FE models include stud diameter, stud strength, angle of outer layer of cross-laminated timber (CLT) panel, tapered groove configurations, and thickness of CLT panel. The numerical results indicated that the shear capacity and stiffness of the GSC connections were mainly influenced by stud diameter, stud strength, angle of outer layer of CLT panel, and the angle of the tapered grooves. Moreover, the FE simulated shear capacity of the GSC connections were compared with the results predicted by the available calculation formulas in design codes and literatures. Finally, the group effect of the GSC connections with multiple rows of studs was discussed based on the numerical results and parametric analyses. An effective row number of studs was proposed to characterize the group effect of the GSC connections.

16 June 2020 in Materials
Verified
Journal Article
Open access
PDF file
LLLiquan Luo
Liquan Luo
BSBenkai Shi
Benkai Shi
WLWeiqing Liu
Weiqing Liu
Huifeng YangHuifeng Yang
Huifeng Yang
Zhibin LingZhibin Ling
Zhibin Ling
This paper presents an experimental evaluation of the fire resistance of glued-in rod timber joints using epoxy resin, with and without modification. A heat-resistant modified resin was designed by adding inorganic additives into the epoxy resin, aiming to improve the heat resistance. Joints that were made using the modified epoxy resin at room temperature showed a bearing capacity comparable to those with commercial epoxy resin. Twenty-one joint specimens with the modified epoxy resin and six with a commercial epoxy resin were tested in a fire furnace to evaluate the fire resistance. The main failure mode was the pull-out of the rod, which is typical in fire tests of this type of joints. As to the effects of the test parameters, this study considered the effects of adhesive types, sectional sizes, stress levels, and fireproof coatings. The test results showed that the fire resistance period of a joint can be evidently improved by modifying the resin and using the fireproof coating, as the improvements reached 73% and 35%, respectively, compared with the joint specimens with commercial epoxy resin. It was also found that, for all specimens, the fire resistance period decreased with an increase in the stress level and increased with an increase in the sectional sizes.

23 August 2023 in Journal of Building Engineering
Verified
Journal Article
Closed access
Zhibin LingZhibin Ling
Zhibin Ling
ZLZheng Li
Zheng Li
FLFan Lu
Fan Lu
HYHuifeng Yang
Huifeng Yang
WZWei Zheng
Wei Zheng
LZLingfeng Zhang
Lingfeng Zhang

20 July 2023 in Buildings
Verified
Journal Article
Open access
PDF file
XLXingxing Liu
Xingxing Liu
WLWeidong Lu
Weidong Lu
KLKaifeng Liu
Kaifeng Liu
FXFengyan Xu
Fengyan Xu
Zhibin LingZhibin Ling
Zhibin Ling
Kong YueKong Yue
Kong Yue
This paper comprehensively investigates the moment-rotation relationship of straight mortise-tenon joints commonly used in Chinese antique timber buildings, focusing on analyzing the local compression mechanism at the tenon end-mortise and the tenon neck-mortise contact areas. Different compression tests were performed, and the experimental compressive stress-strain curves displayed a typical bi-linear response comprising an elastic increasing response followed by a plastic stage. The specimens subjected to middle local compression tests exhibited higher yield stress, elastic modulus, and plastic modulus than the others. Cyclic loading tests were conducted on twelve mortise-tenon joints with varying lengths, widths, and heights of the tenon to investigate the rotational behavior of the joints under alternating loading directions. The hysteresis curves of the tested specimens generally showed a “Z” shaped pinching effect, indicating limited energy dissipation of the joints during cyclic loading. The length and width of the tenon were observed to have a significant influence on the joint rotational behavior. Finally, a theoretical model was proposed to predict the moment-rotation relationship of the mortise-tenon joint, considering the proposed bilinear stress-strain relationship for wood under compression perpendicular to the grain. The predicted results obtained by the proposed theoretical model were generally validated by the experimental results.

2 May 2025 in BioResources
Verified
Journal Article
Closed access
Zhibin LingZhibin Ling
Zhibin Ling
ZLZheng Li
Zheng Li
ZLZhoujun Li
Zhoujun Li
CYChao Yang
Chao Yang
WZWei Zheng
Wei Zheng
LZLingfeng Zhang
Lingfeng Zhang
Cross-laminated timber (CLT), known for its high performance, prefabrication, low carbon emission, and eco-friendliness, has gained widespread adoption in the construction industry. Glued-in rod (GiR) connections, which offer a concealed appearance, high strength, withdrawal stiffness, ease of construction, and fire resistance, have become a promising solution for CLT structures. This study experimentally investigated the axial pull-out behavior of GiR connections in CLT. Forty-five CLT specimens with single GiR were designed and tested under pull-out conditions. The experimental variables included embedment length, threaded rod diameter, and rod-to-grain angle (parallel and perpendicular). The results revealed that CLT connections with GiR parallel to the grain exhibited an ascending load-slip response until peak load, followed by a sudden failure, while those with GiR perpendicular to the grain showed a linear increase to peak load with a subsequent gradual load reduction. Increasing the embedment length from 5 d to 15 d enhanced the pull-out load but decreased the average bond stress. Additionally, larger rod diameters led to higher pull-out loads and withdrawal stiffness within a certain range but reduced the average bond stress. The study also evaluated the effectiveness of existing bond stress-slip models and pull-out load prediction models for GiR connections in CLT, providing a foundation for future standardization efforts.