The fault tolerance of electric drives is highly appreciated at industry for security and economic reasons, and the inherent redundancy of six-phase machines provides the desired fault-tolerant capability with no extra hardware. For this reason some recent research efforts have been focused on the fault-tolerant design, modeling, and control of six-phase machines. Nevertheless, a unified and conclusive analysis of the postfault capability of six-phase machine is still missing. This paper provides a full picture of the postfault derating in generic six-phase machines and a specific analysis of the fault-tolerant capability of the three mainstream six-phase induction machines (asymmetrical, symmetrical, and dual three phase). Experimental results confirm the theoretical post fault current limits and allow concluding, which is the best six-phase machine for each fault scenario and neutral arrangement.
19 September 2016 in IEEE Transactions on Industrial Electronics
Direct torque control (DTC) has been widely used as an alternative to traditional field-oriented control (FOC) methods for three-phase drives. The conventional DTC scheme has been successfully extended to multiphase drives in recent times, using hysteresis regulators to independently track the desired torque and flux in symmetrical five-phase induction machines (IMs). The fault-tolerant capability of multiphase drives is an interesting intrinsic advantage for safety-critical applications, where recent research has demonstrated the effectiveness of FOC schemes to perform ripple-free postfault operation. In spite of the utility of DTC methods in normal operation of the multiphase machine, no extension to manage the postfault operation of the drive is found in the literature. In this paper, a novel fault-tolerant DTC scheme is presented. The performance of the proposed method is experimentally validated in a five-phase IM drive considering an open-phase fault condition. Provided tests analyze steady and transient states, including the transition from pre- to postfault operation. Obtained results prove the interest of the proposal, which ensures the open-phase fault-tolerant capability of DTC-controlled five-phase IM drives.
4 October 2019 in IEEE Transactions on Industrial Electronics
Multiphase machines provide continuous operation of the drive with no additional hardware in the event of one or more open-phase faults. This fault-tolerant capability is highly appreciated by industry for security and economic reasons. However, the steady-state post-fault operation has only been feasible in previous works after the fault localization and control reconfiguration. Even though this is done at the software stage, the obligation to identify the faulty phases and store the modifications for every fault scenario adds further complexity. This work reveals that this software reconfiguration can be avoided if the field-oriented control (FOC) strategy is designed to satisfactorily handle pre- and post-fault situations. Experimental results confirm the capability to obtain suitable post-fault operation without fault localization and control reconfiguration, thus achieving a passive/natural fault tolerance.
5 June 2017 in IEEE Transactions on Power Electronics
Direct torque control (DTC) has been recently used for the development of high-performance five-phase induction motor (IM) drives, where normal operation of the system has been usually considered and the ability of DTC to manage the situation has been analyzed in comparison with different rotor-field-oriented control (RFOC) strategies. The exploitation of fault-tolerant capabilities is also an interesting issue in multiphase machines, where the utility of RFOC controllers has been stated when the open-phase fault operation is considered. In this paper, the performance of DTC and RFOC controllers based on proportional resonant regulators and predictive control techniques is compared when an open-phase fault appears in a five-phase IM drive. Experimental tests are provided to compare the performance of the system using these control alternatives.
8 May 2019 in IEEE Journal of Emerging and Selected Topics in Power Electronics
The inherent fault-tolerant capability of multiphase machines is highly appreciated, but it requires fault detection and localization together with a reconfiguration of the control scheme. When the multiphase machine is regulated using finite-control set model predictive control (MPC) strategies, the reconfiguration involves the use of different transformation matrices, cost functions and current references for each of the multiple open-phase fault (OPF) scenarios. Aiming to simplify this procedure and add further robustness, this paper explores the possibility to achieve a natural fault-tolerant capability by maintaining the pre-fault control strategy after the fault occurrence. For this purpose, this work firstly analyzes the two main reasons why MPC-regulated multiphase drives misbehave in the event of an OPF: the voltage vector shifting and the search for incompatible goals. In a next step, a version of the MPC that includes virtual voltage vectors (VVs) is tested for the first time in post-fault situation and it is compared to conventional MPC technique. Extensive experimental results reveal that, while MPC misbehaves in the event of an OPF, the VV-MPC provides a satisfactory ripple-free post-fault performance. This finding has two significant implications for industrial applications: the post-fault operation is highly simplified and, at the same time, the fault-tolerant multiphase drive becomes immune to fault detection errors and delays.
28 July 2015 in IEEE Transactions on Industrial Electronics
Multiphase drives and parallel converters have been recently proposed in low-voltage high-power applications. The fault-tolerant capability provided by multiphase drives is then extended with parallel converters, increasing their suitability for safety-critical and renewable uses. This advantageous feature, compared with standard three-phase drives, has been analyzed in the event of open-phase faults. However, when using parallel converters, a converter fault does not necessarily imply an open-phase condition, but usually just a limited phase current capability. This paper analyzes the fault-tolerant capability of six-phase drives with parallel converter supply. Different scenarios considering up to three faults for single and two neutral configurations are examined, optimizing offline the postfault currents and modifying accordingly the control strategies. Experimental results confirm the smooth transition from prefault to postfault situation and the enhanced postfault torque capability.