The paper presents a study of postfault control for an asymmetrical six-phase induction machine with single and two isolated neutral points, during single open-phase fault. Postfault control is based on the normal decoupling (Clarke) transformation, so that reconfiguration of the controller is minimized. Effect of the single open-phase fault on the machine equations under this control structure is discussed. Different modes of postfault operation are analyzed and are further compared in terms of the achievable torque and stator winding losses. Validity of the analysis is verified using experimental results obtained from a six-phase induction motor drive prototype.
12 December 2013 in IEEE Transactions on Power Electronics
Leakage current minimization is one of the most important considerations in transformerless photovoltaic (PV) inverters. In the past, various transformerless PV inverter topologies have been introduced, with leakage current minimized by the means of galvanic isolation and common-mode voltage (CMV) clamping. The galvanic isolation can be achieved via dc-decoupling or ac-decoupling, for isolation on the dc- or ac-side of the inverter, respectively. It has been shown that the latter provides lower losses due to the reduced switch count in conduction path. Nevertheless, leakage current cannot be simply eliminated by galvanic isolation and modulation techniques, due to the presence of switches' junction capacitances and resonant circuit effects. Hence, CMV clamping is used in some topologies to completely eliminate the leakage current. In this paper, several recently proposed transformerless PV inverters with different galvanic isolation methods and CMV clamping technique are analyzed and compared. A simple modified H-bridge zero-voltage state rectifier is also proposed, to combine the benefits of the low-loss ac-decoupling method and the complete leakage current elimination of the CMV clamping method. The performances of different topologies, in terms of CMV, leakage current, total harmonic distortion, losses and efficiencies are compared. The analyses are done theoretically and via simulation studies, and further validated with experimental results. This paper is helpful for the researchers to choose the appropriate topology for transformerless PV applications and to provide the design principles in terms of common-mode behavior and efficiency.
23 November 2016 in IEEE Transactions on Power Electronics
The fault tolerance of electric drives is highly appreciated at industry for security and economic reasons, and the inherent redundancy of six-phase machines provides the desired fault-tolerant capability with no extra hardware. For this reason some recent research efforts have been focused on the fault-tolerant design, modeling, and control of six-phase machines. Nevertheless, a unified and conclusive analysis of the postfault capability of six-phase machine is still missing. This paper provides a full picture of the postfault derating in generic six-phase machines and a specific analysis of the fault-tolerant capability of the three mainstream six-phase induction machines (asymmetrical, symmetrical, and dual three phase). Experimental results confirm the theoretical post fault current limits and allow concluding, which is the best six-phase machine for each fault scenario and neutral arrangement.
21 February 2013 in IEEE Transactions on Power Electronics
Using the vector space decomposition approach, the currents in a multiphase machine with distributed winding can be decoupled into the flux and torque producing α-β components, and the loss-producing x-y and zero-sequence components. While the control of α-β currents is crucial for flux and torque regulation, control of x-y currents is important for machine/converter asymmetry and dead-time effect compensation. In this paper, an attempt is made to provide a physically meaningful insight into current control of a six-phase machine, by showing that the fictitious x-y currents can be physically interpreted as the circulating currents between the two three-phase windings. Using this interpretation, the characteristics of x-y currents due to the machine/converter asymmetry can be analyzed. The use of different types of x-y current controllers for asymmetry compensation and suppression of dead-time-induced harmonics is then discussed. Experimental results are provided throughout the paper, to underpin the theoretical considerations, using tests on a prototype asymmetrical six-phase induction machine.
2 June 2014 in IEEE Transactions on Industrial Electronics
Recently, reduced common-mode voltage (CMV) pulsewidth modulation (RCMV-PWM) methods have been proposed to reduce the leakage current in three-phase transformerless photovoltaic (PV) systems. However, most of these studies only focus on leakage current elimination and neglect the overall performance of the PV systems on issues such as cost, voltage linearity, dc-link current ripples, and harmonic distortion. In this paper, a three-phase transformerless inverter, adapted from the single-phase H5 topology, is investigated. Since the H5 topology has been conventionally developed for a single-phase system, its adaptation to the three-phase system requires the development of corresponding three-phase modulation techniques. Hence, modulation techniques are proposed based on conventional PWM. The performances of the proposed PWM, in terms of CMV, leakage current, voltage linearity, output current ripples, dc-link current ripples, and harmonic distortion are studied and discussed via simulation and experiment. It is proven that the proposed topology is able reduce the leakage current without sacrificing the overall performance of the system.