Environmental biophysical interactions are recognized to play an essential part in the human biological processes associated with trauma recovery. Many studies over several decades have furthered our understanding of the effects that Pulsed Electromagnetic Fields (PEMF) have on the human body, as well as on cellular and biophysical systems. These investigations have been driven by the observed positive clinical effects of this non-invasive treatment on patients, mainly in orthopedics. Unfortunately, the diversity of the various study setups, with regard to physical parameters, molecular and cellular response, and clinical outcomes, has made it difficult to interpret and evaluate commonalities, which could, in turn, lead to finding an underlying mechanistic understanding of this treatment modality. In this review, we give a birds-eye view of the vast landscape of studies that have been published on PEMF, presenting the reader with a scaffolded summary of relevant literature starting from categorical literature reviews down to individual studies for future research studies and clinical use. We also highlight discrepancies within the many diverse study setups to find common reporting parameters that can lead to a better universal understanding of PEMF effects.
Angiogenesis is a highly regulated process. It promotes tissue regeneration and contributes to tumor growth. Existing therapeutic concepts interfere with different steps of angiogenesis. The quantification of the vasculature is of crucial importance for research on angiogenetic effects. The chorioallantoic membrane (CAM) assay is widely used in the study of angiogenesis. Ex ovo cultured chick embryos develop an easily accessible, highly vascularised membrane on the surface. Tumor xenografts can be incubated on this membrane enabling studies on cancer angiogenesis and other major hallmarks. However, there is no commonly accepted gold standard for the quantification of the vasculature of the CAM. We compared four widely used measurement techniques to identify the most appropriate one for the quantification of the vascular network of the CAM. The comparison of the different quantification methods suggested that the CAM assay application on the IKOSA platform is the most suitable image analysis application for the vasculature of the CAM. The new CAM application on the IKOSA platform turned out to be a reliable and feasible tool for practical use in angiogenesis research. This novel image analysis software enables a deeper exploration of various aspects of angiogenesis and might support future research on new anti-angiogenic strategies for cancer treatment.
Photobiomodulation, showing positive effects on wound healing processes, has been performed mainly with lasers in the red/infrared spectrum. Light of shorter wavelengths can significantly influence biological systems. This study aimed to evaluate and compare the therapeutic effects of pulsed LED light of different wavelengths on wound healing in a diabetic (db/db) mouse excision wound model. LED therapy by Repuls was applied at either 470 nm (blue), 540 nm (green) or 635 nm (red), at 40 mW/cm2 each. Wound size and wound perfusion were assessed and correlated to wound temperature and light absorption in the tissue. Red and trend-wise green light positively stimulated wound healing, while blue light was ineffective. Light absorption was wavelength-dependent and was associated with significantly increased wound perfusion as measured by laser Doppler imaging. Shorter wavelengths ranging from green to blue significantly increased wound surface temperature, while red light, which penetrates deeper into tissue, led to a significant increase in core body temperature. In summary, wound treatment with pulsed red or green light resulted in improved wound healing in diabetic mice. Since impeded wound healing in diabetic patients poses an ever-increasing socio-economic problem, LED therapy may be an effective, easily applied and cost-efficient supportive treatment for diabetic wound therapy.
Investigations reporting positive effects of extracorporeal shockwave therapy (ESWT) on nerve regeneration are limited to the rat sciatic nerve model. The effects of ESWT on muscle-in-vein conduits (MVCs) have also not been investigated yet. This study aimed to evaluate the effects of ESWT after repair of the rat median nerve with either autografts (ANGs) or MVCs. In male Lewis rats, a 7 mm segment of the right median nerve was reconstructed either with an ANG or an MVC. For each reconstructive technique, one group of animals received one application of ESWT while the other rats served as controls. The animals were observed for 12 weeks, and nerve regeneration was assessed using computerized gait analysis, the grasping test, electrophysiological evaluations and histological quantification of axons, blood vessels and lymphatic vasculature. Here, we provide for the first time a comprehensive analysis of ESWT effects on nerve regeneration in a rat model of median nerve injury. Furthermore, this study is among the first reporting the quantification of lymphatic vessels following peripheral nerve injury and reconstruction in vivo. While we found no significant direct positive effects of ESWT on peripheral nerve regeneration, results following nerve repair with MVCs were significantly inferior to those after ANG repair.
In vitro investigations, which comprise the bulk of research efforts geared at identifying an underlying biomechanical mechanism for extracorporeal shock wave therapy (ESWT), are commonly hampered by inadequate descriptions of the underlying therapeutic acoustical pressure waves. We demonstrate the necessity of in-situ sound pressure measurements inside the treated samples considering the significant differences associated with available applicator technologies and cell containment. A statistical analysis of pulse-to-pulse variability in an electrohydraulic applicator yields a recommendation for a minimal pulse number of n = 300 for cell pallets and suspensions to achieve reproducible treatments. Non-linear absorption behavior of sample holders and boundary effects are shown for transient peak pressures and applied energies and may serve as a guide when in-situ measurements are not available or can be used as a controllable experimental design factor. For the use in microbiological investigations of ESWT we provide actionable identification of common problems in describing physical shockwave parameters and improving experimental setups by; (1) promoting in-situ sound field measurements, (2) statistical evaluation of applicator variability, and (3) extrapolation of treatment parameters based on focal and treatment volumes.
The potential beneficial regenerative and stimulatory extracorporeal shock wave therapy (ESWT) applications to the central nervous system have garnered interest in recent years. Treatment zones for these indications are acoustically shielded by bones, which heavily impact generated sound fields. We present the results of high-resolution tissue-realistic simulations, comparing the viability of different ESWT applicators in their use for transcranial applications. The performances of electrohydraulic, electromagnetic, and piezoelectric transducers for key reflector geometries are compared. Based on density information obtained from CT imaging of the head, we utilized the non-linear wave propagation toolset Matlab k-Wave to obtain spatial therapeutic sound field geometries and waveforms. In order to understand the reliability of results on the appropriate modeling of the skull, three different bone attenuation models were compared. We find that all currently clinically ESWT applicator technologies show significant retention of peak pressures and energies past the bone barrier. Electromagnetic transducers maintain a significantly higher energy flux density compared to other technologies while low focusing strength piezoelectric applicators have the weakest transmissions. Attenuation estimates provide insights into sound field degradation and energy losses, indicating that effective transcranial therapies can readily be attained with current applicators. Furthermore, the presented approach will allow for future targeted in silico development and the design of applicators and therapy plans to ultimately improve therapeutic outcomes.