Rania A. Ibrahim

Dr. Rania A. Ibrahim

orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 November 2024 in Scientific Reports
Verified
Journal Article
Open access
PDF file
Rania A. IbrahimRania A. Ibrahim
Rania A. Ibrahim
IGIbrahim. M. Gaber
Ibrahim. M. Gaber
NZNahla E. Zakzouk
Nahla E. Zakzouk
Moving towards a cleaner, greener, and more sustainable future, expanding electric vehicles (EVs) adoption is inevitable. However, uncontrolled charging of EVs, especially with their increased penetration among the utility grid, imposes several negative technical impacts, including grid instability and deteriorated power quality in addition to overloading conditions. Hence, smart and coordinated charging is crucial in EV electrification, where Vehicle-to-Grid (V2G) technology is gaining much interest. Owing to its inherited capability of bi-directional power flow, V2G is capable of enhancing grid stability and resilience, load balancing, and congestion alleviation, as well as supporting renewable energy sources (RESs) integration. However, as with most emerging technologies, there are still technical research gaps that need to be addressed. In addition to these technical impacts, other multidisciplinary factors must be investigated to promote EVs adoption and V2G implementation. This paper provides a detailed demonstration of the technical problems associated with EVs penetration in distribution networks along with quantifiable insights into these limitations and the corresponding mitigation schemes. In addition, it discusses V2G benefits for power systems and consumers, as well as explores their technical barriers and research directions to adequately regulate their services and encourage EV’s owners to its embracement. Moreover, other factors, including regulatory, social, economic and environmental ones that affect EV market penetration are being studied and related challenges are analyzed to draw recommendations that aid market growth.

22 December 2022 in Renewable Energy
Verified
Journal Article
Closed access
OAOmneya Attallah
Omneya Attallah
Rania A. IbrahimRania A. Ibrahim
Rania A. Ibrahim
NZNahla E. Zakzouk
Nahla E. Zakzouk

11 October 2022 in Energy Reports
Verified
Journal Article
Open access
OAOmneya Attallah
Omneya Attallah
Rania A. IbrahimRania A. Ibrahim
Rania A. Ibrahim
NZNahla E. Zakzouk
Nahla E. Zakzouk

1 June 2012
Verified
Conference Paper
Closed access
Rania A. IbrahimRania A. Ibrahim
Rania A. Ibrahim
MHMostafa Saad Hamad
Mostafa Saad Hamad
YDY. G. Dessouky
Y. G. Dessouky
BWB. W. Williams
B. W. Williams
Research of grid connected wind turbines has gained great interest in the recent years. This led to introduce guidelines and regulations regarding the connection of large wind farms to the electrical network. One of such guidelines is low voltage ride-through capability (LVRT). In this paper, a survey on recent LVRT solutions for permanent magnet synchronous generators (PMSG) is carried out along with a brief explanation of grid codes. Among those solutions is the control of fully rated converters, blade pitch angle control and capacitor sizing. Other solutions such as active crowbar rotor circuit and the DC bus energy storage circuit are illustrated. The survey extends to provide possibilities for the development of further LVRT research at the wind farm level using high power FACT devices.

18 January 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Rania A. IbrahimRania A. Ibrahim
Rania A. Ibrahim
NZNahla E. Zakzouk Zakzouk
Nahla E. Zakzouk Zakzouk
Low-voltage ride-through (LVRT) and grid support capability are becoming a necessity for grid-tied renewable energy sources to guarantee utility availability, quality and reliability. In this paper, a swap control scheme is proposed for grid-tied permanent magnet synchronous generator (PMSG) MW-level wind turbines. This scheme shifts system operation from maximum power point tracking (MPPT) mode to LVRT mode, during utility voltage sags. In this mode, the rectifier-boost machine-side converter overtakes DC-link voltage regulation independently of the grid-side converter. The latter attains grid synchronization by controlling active power injection into the grid to agree with grid current limits while supporting reactive power injection according to the sag depth. Thus grid code requirements are met and power converters safety is guaranteed. Moreover, the proposed approach uses the turbine-generator rotor inertia to store surplus energy during grid voltage dips; thus, there is no need for extra hardware storage devices. This proposed solution is applied on a converter topology featuring a minimal number of active switches, compared to the popular back-to-back converter topology. This adds to system compatibility, reducing its size, cost and switching losses. Simulation and experimental results are presented to validate the proposed approach during normal and LVRT operation.

4 March 2022
Verified
Conference Paper
Closed access
MYMohamed M. Youssef
Mohamed M. Youssef
Rania A. IbrahimRania A. Ibrahim
Rania A. Ibrahim
HDHussein Desouki
Hussein Desouki
MMMohamed M. Zakaria Moustafa
Mohamed M. Zakaria Moustafa
The demand to improve grid infrastructure is of utmost importance especially with the increased expansion and addition of distributed generation units to cope with today’s era of transforming to smart grids. The health status of distribution transformers in an electrical grid plays a vital role in maintaining network service continuity, safety from catastrophic events, and reliability of utility operation. Monitoring transformer’s health is essential for minimizing outages and extending its life in service. Various diagnostic tests and fault detection techniques have developed to effectively support utility operators in predicting failure, estimating life expectancy and condition monitor its status. For these reasons, traditional and advanced methods are required to reduce maintenance time, cost, and help in finding fault causes and location easily. This paper gives a thorough overview about widely used and latest condition monitoring techniques while highlighting strengths and limitations of each.