Irfan Muhammad

Dr. Irfan Muhammad


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 July 2022 in Chemosphere
Verified
Journal Article
Closed access
SZShafiq Uz Zaman
Shafiq Uz Zaman
SRSikander Rafiq
Sikander Rafiq
AAAbulhassan Ali
Abulhassan Ali
MMMuhammad Shozab Mehdi
Muhammad Shozab Mehdi
AAAmber Arshad
Amber Arshad
Pau Loke ShowPau Loke Show
Pau Loke Show

16 March 2022 in Membranes
Verified
Journal Article
Open access
PDF file
IMIrfan Muhammad
Irfan Muhammad
MIMasooma Irfan
Masooma Irfan
AIAni Idris
Ani Idris
AAAbdullah Alsubaie
Abdullah Alsubaie
KMKhaled H. Mahmoud
Khaled H. Mahmoud
NANaeem Akhtar
Naeem Akhtar
Commercial grade sulfonated-Polyethersulfone (S-PES) and functionalized multiwall carbon nanotube (f-MWCNT)/polyvinylpyrrolidone (PVP) nanocomposites (NCs) were used to enhance and optimize the antifouling, protein resistance and protein separation properties of the S-PES ultrafiltration membranes. The polarities of sulfonic groups of S-PES, carbonyl carbon of pyrrolidone, hydroxyl and carboxyl groups of f-MWCNT in the membrane composition helped to strongly bind each other through hydrogen bonding, as shown by Fourier-transform infrared spectroscopy (FTIR). These binding forces greatly reduced the leaching of NCs and developed long finger-like projection, as confirmed by elution ratio and cross-sectional studies of the membranes via field emission scanning electron microscope (FESEM). The contact angle was reduced up to 48% more than pristine PES. Atomic force microscopy (AFM) was employed to study the various parameters of surface roughness with 3d diagrams, while grain analysis of membrane surface provided a quantitative estimation about volume, area, perimeter, length, radius and diameter. The NCs/S-PES enhanced the flux rate with an impressive (80–84%) flux recovery ratio and (58–62%) reversible resistance (Rr) value in situ, with 60% and 54.4% lesser dynamic and static protein adsorption. The best performing membrane were reported to remove 31.8%, 66.3%, 83.6% and 99.9% for lysozyme-(14.6 kDa), trypsin-(20 kDa), pepsin-(34.6 kDa) and bovine serum albumin (BSA-66 kDa), respectively.

9 March 2022 in Membranes
Verified
Journal Article
Open access
PDF file
IMIrfan Muhammad
Irfan Muhammad
MIMasooma Irfan
Masooma Irfan
AIAni Idris
Ani Idris
AAAbdullah Alsubaie
Abdullah Alsubaie
KMKhaled H. Mahmoud
Khaled H. Mahmoud
NMNawshad Muhammad
Nawshad Muhammad
This study investigated the influence of dope extrusion rate (DER) and post-treatment effect on the morphology, permeation, and metal ion rejection by polyethersulfone/lithium bromide (PES/LiBr)-based hollow fiber (HF) membranes. HF fibers were spun with 2.25, 2.5, and 3.1 ratios of DER to bore fluid rate (BFR), wherein DER varied from 11.35, 12.5, to 15.6 mL/min with a fixed BFR (5 mL/min). Molecular weight cutoff (MWCO), pore size, water flux, and flux recovery ratio were determined, whereas lake water was used to observe the rejection rate of dissolved metallic ions. Results showed that with the increase of the DER wall thickness (WT), HFs increased from 401.5 to 419.5 um, and furthermore by the post-treatments up to 548.2 um, as confirmed by field emission scanning electron microscope (FESEM) analysis. Moreover, MWCO, pore size, and the pure water permeation (PWP) of the HF membranes decreased, while the separation performance for polyethylene glycol (PEG) solute increased with increasing DER. Post-treated HFs from 11.35 mL/min of DER showed 93.8% of MWCO value with up to 90% and 70% rejection of the arsenic and chromium metallic ions, respectively, in comparison with all other formulated HFs.

1 August 2025 in Journal of Applied Membrane Science & Technology
Verified
Journal Article
Open access
PDF file
MIMasooma Irfan
Masooma Irfan
TNTahira Nasir
Tahira Nasir
UHUsman Haider
Usman Haider
IMIrfan Muhammad
Irfan Muhammad
A wide range of synthetic polymers is employed in hemodialysis (HD) applications, each offering unique advantages and potential limitations that can impact patient outcomes. These polymers are primarily chosen for their excellent permeability to uremic solutes and superior biocompatibility, which are critical for efficient blood purification. However, challenges such as membrane fouling, protein adsorption and long-term blood compatibility remain concerns that can affect the overall efficacy and safety of the treatment. In recent years, advances in polymer engineering have led to the development of new membrane materials with improved selectivity, durability, and reduced inflammatory response. Polysulfone (PS), polyurethane (PU), polyethersulfone (PES) and polyacrylonitrile (PAN) are among the most widely used polymers in commercial dialyzers, each with specific performance characteristics tailored to patient needs. In the current review, we overviewed various types of polymers used as hemodialyzer material and their contribution to enhance patient life span.

27 May 2025 in Emergent Materials
Verified
Journal Article
Closed access
PDF file
MIMasooma Irfan
Masooma Irfan
UHUsman Haider
Usman Haider
IMIrfan Muhammad
Irfan Muhammad
HMHotaf Hassan Makki
Hotaf Hassan Makki
MKMarouan KOUKI
Marouan KOUKI
AHAyaz Hassan
Ayaz Hassan