Antonio Maria Tardo

Dr. Antonio Maria Tardo

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 March 2023 in Veterinary Sciences
Verified
Journal Article
Open access
PDF file
MRMariachiara Re
Mariachiara Re
FBFrancesca Del Baldo
Francesca Del Baldo
ATAntonio Maria Tardo
Antonio Maria Tardo
FFFederico FRACASSI
Federico FRACASSI
The flash glucose monitoring system (FGMS) has recently become one of the most common monitoring methods in dogs and cats with diabetes mellitus. The aim of this study was to evaluate the impact of FGMS on the quality of life of diabetic pet owners (DPOs). Fifty DPOs were asked to answer a 30-question survey. More than 80% of DPOs considered FGMS easier to use and less stressful and painful for the animal compared to blood glucose curves (BGCs). Overall, 92% of DPOs reported that their pet had better diabetes control since using FGMS. The most challenging aspects of using the FGMS were ensuring proper sensor fixation during the wearing period (47%), preventing premature detachment (40%), and purchasing the sensor (34%). Moreover, 36% of DPOs reported that the device cost was difficult to afford in the long term. Comparing dogs and cats, a significantly higher number of dogs’ owners found the FGMS to be well-tolerated (79% vs. 40%), less invasive than BGCs (79% vs. 43%), and easier to maintain in situ (76% vs. 43%). In conclusion, FGMS is considered by DPOs to be easy to use and less stressful compared to BGCs, while enabling better glycemic control. Nevertheless, the costs related to its long-term use might be difficult to sustain.

9 December 2022 in Animals
Verified
Journal Article
Open access
PDF file
Carlo GuglielminiCarlo Guglielmini
Carlo Guglielmini
PCPaolo Emidio Crisi
Paolo Emidio Crisi
ATAntonio Maria Tardo
Antonio Maria Tardo
RMRoberta Di Maggio
Roberta Di Maggio
Barbara ContieroBarbara Contiero
Barbara Contiero
Arianna MiglioArianna Miglio
Arianna Miglio
This study aimed to assess the prognostic value of red cell distribution width (RDW) RDW-to-calcium ratio (RDW/Ca), neutrophils-to-lymphocytes ratio (N/L), platelets-to-lymphocytes ratio (P/L) and other easy to obtain and inexpensive hematological and biochemical parameters in dogs with acute pancreatitis. This is a multicenter, retrospective cohort study including 70 client-owned dogs. The accuracy of clinical and laboratory variables to predict short-term death (i.e., dead by 14 days) was tested by calculating the area under the receiver-operating characteristic curve (AUC). Independent predictors of death were identified using the multivariable Cox proportional hazards regression model. The survival rate was 72.9% (51 dogs) and 19 dogs died within 14 days of admission from AP. RDW and blood urea nitrogen (BUN) had good accuracy to predict short-term dead with AUC of 0.74 and 0.70 at the cut-off of >12.7% and >42 mg/dL, respectively. According to the multivariable model, RDW (hazard ratio and 95% confidence interval [HR, 95% CI] = 5.08, 95% CI = 1.14–22.67; p = 0.03), BUN (HR = 1.00, 95% CI = 1.00–1.01; p < 0.01) and bilirubin (HR = 2.46, 95% CI = 1.38–4.39; p < 0.01) were independent predictors of death. The results indicate that RDW, BUN and bilirubin are useful predictors of short-term death in dogs with acute pancreatitis.

1 July 2024 in Journal of Veterinary Internal Medicine
Verified
Journal Article
Open access
ATAntonio Maria Tardo
Antonio Maria Tardo
LFLinda Mary Fleeman
Linda Mary Fleeman
FFFederico FRACASSI
Federico FRACASSI
ABAlisa Saule Berg
Alisa Saule Berg
AGAria L. Guarino
Aria L. Guarino
CGChen Gilor
Chen Gilor
Background: In purpose-bred dogs, insulin glargine 300 U/mL (IGla300) has long duration of action, peakless time-action profile, and low potency, making it suitable for use as a basal insulin. Hypothesis: To evaluate IGla300 in client-owned diabetic dogs monitored using a flash glucose monitoring system (FGMS). Animals: Ninety-five client-owned diabetic dogs, newly diagnosed or previously treated with other insulin formulations, with or without concurrent diseases. Methods: Prospective multi-institutional study. Clinical signs and standardized assessment of FGMS data, using treatment and monitoring guidelines established a priori, guided dose adjustments and categorization into levels of glycemic control. Results: The initial IGla300 dose was 0.5 U/Kg q24h for newly diagnosed dogs and (median dose [range]) 0.8 U/Kg (0.2-2.5) q24h for all dogs. Glycemic control was classified as good or excellent in 87/95 (92%) dogs. The IGla300 was administered q24h (1.9 U/kg [0.2-5.2]) and q12h (1.9 U/kg/day [0.6-5.0]) in 56/95 (59%) and 39/95 (41%) dogs, respectively. Meal-time bolus injections were added in 5 dogs (0.5 U/kg/injection [0.3-1.0]). Clinical hypoglycemia occurred in 6/95 (6%) dogs. Dogs without concurrent diseases were more likely to receive IGla300 q24h than dogs with concurrent diseases (72% vs 50%, respectively; P = .04). Conclusions and Clinical Importance: Insulin glargine 300 U/mL can be considered a suitable therapeutic option for once-daily administration in diabetic dogs. Clinicians should be aware of the low potency and wide dose range of IGla300. In some dogs, twice-daily administration with or without meal-time bolus injections may be necessary to achieve glycemic control. Monitoring with FGMS is essential for dose titration of IGla300.

1 March 2024 in Journal of Veterinary Internal Medicine
Verified
Journal Article
Open access
FBFrancesca Del Baldo
Francesca Del Baldo
ACAndrea Corsini
Andrea Corsini
ATAntonio Maria Tardo
Antonio Maria Tardo
ATAlessandro Tirolo
Alessandro Tirolo
ASAda Sapignoli
Ada Sapignoli
FFFederico FRACASSI
Federico FRACASSI
Background: In dogs, duration of hypothalamic-pituitary-adrenal (HPA) axis suppression after systemic glucocorticoid treatment is reported to vary from a few days to up to 7 weeks after glucocorticoid discontinuation. These data are derived mainly from experimental studies in healthy dogs and not from animals with spontaneous disease. Hypothesis and Objective: To determine the timeline for recovery of the HPA axis in a group of ill dogs treated with intermediate-acting glucocorticoids (IAGCs). Animals: Twenty client-owned dogs that received IAGC for at least 1 week. Methods: Single-center prospective observational study. An ACTH stimulation test, endogenous ACTH concentration, serum biochemistry profile, and urinalysis were performed at T0 (2-6 days after IAGC discontinuation) and then every 2 weeks (eg, T1, T2, T3) until HPA axis recovery was documented (post-ACTH cortisol concentration > 6 μg/dL). Results: The median time of HPA axis recovery was 3 days (range, 2-133 days). Eleven of 20 dogs showed recovery of the HPA axis at T0, 6/20 at T1, and 1 dog each at T2, T5, and T9. Dose and duration of treatment were not correlated with timing of HPA axis recovery. Activities of ALT and ALP were significantly correlated with the post-ACTH cortisol concentration (rs = −0.34, P = .03; rs = −0.31, P = .05). Endogenous ACTH concentration was significantly correlated with pre (r = 0.72; P < .0001) and post-ACTH cortisol concentrations (r = 0.35; P = .02). The timing of HPA axis recovery of the dogs undergoing an alternate-day tapering dose was not different compared to dogs that did not (3.5 vs 3 days, P = .89). Conclusion and Clinical Importance: Most dogs experienced HPA axis recovery within a few days after IAGC discontinuation. However, 2/20 dogs required >8 weeks.

1 January 2025 in Journal of Veterinary Internal Medicine
Verified
Journal Article
Open access
JMJocelyn Mott
Jocelyn Mott
AGArnon Gal
Arnon Gal
ATAntonio Maria Tardo
Antonio Maria Tardo
ABAlisa Berg
Alisa Berg
RCRiley Claude
Riley Claude
CGChen Gilor
Chen Gilor
Background: The advantages of insulin degludec 100 U/mL (IDeg100) in the treatment of diabetes mellitus (DM) include consistent release, predictable glucose-lowering effect, and minimal day-to-day variability. Hypothesis/Objectives: To describe the use of IDeg100 in dogs with DM, level of diabetic control and adverse effects. Animals: Thirty-three client-owned dogs with DM. Methods: A prospective, multi-institutional, uncontrolled study of newly diagnosed or previously insulin-treated, with or without comorbidities and with or without concurrent medications. Clinical signs and continuous glucose monitoring data were monitored and guided insulin dose adjustments. A per-protocol analysis was performed. Results: The final dose of IDeg100 in dogs was 1.3 U/kg (median, range, 0.4-2.2) achieved in 14 days (median, range, 3-32). Seventy-nine percent (26/33) of the dogs had comorbidities with 42% (11/26) having more than 1 comorbidity. Sixty-four percent (21/33) of dogs were receiving concurrent medications with 62% (13/21) receiving more than 1 non-insulin medication. Seventy-six percent (25/33) were scored as having excellent/very good DM control. From baseline to study exit, dogs showed improvements in both ALIVE DM clinical score (from 3 [0-8, 96.49% CI (2-5)] to 1 [0-7, 96.49% CI (1-2)]; P = .0007) and average 3-day interstitial glucose (from 332.8 ± 68.7 mg/dL, 95% CI [308.8-357.2] to 229.0 ± 56.3 mg/dL [CI 209.0 - 248.9]; P < .0001). Conclusions and Clinical Importance: Insulin degludec 100 U/mL is effective for the treatment of dogs with DM. Eighty-four percent (28/33) of dogs responded to once daily dose of IDeg100 with low frequency of clinical hypoglycemia.

29 March 2022 in Animals
Verified
Journal Article
Open access
PDF file
ATAntonio Maria Tardo
Antonio Maria Tardo
CIConcetta Irace
Concetta Irace
FBFrancesca Del Baldo
Francesca Del Baldo
AFArmando Foglia
Armando Foglia
FFFederico FRACASSI
Federico FRACASSI
The novel Eversense XL continuous glucose monitoring system (Senseonics, Inc., Germantown, Maryland) has recently been developed for monitoring diabetes in humans. The sensor is fully implanted and has a functional life of up to 180 days. The present study describes the use of Eversense XL in three diabetic dogs (DD) with good glycemic control managed by motivated owners. The insertion and use of the device were straightforward and well tolerated by the dogs. During the wearing period, some device-related drawbacks, such as sensor dislocation and daily calibrations, were reported. A good correlation between the glucose values measured by the Eversense XL and those obtained with two commercially available devices, previously validated for use in DD, was found (rs = 0.85 and rs = 0.81, respectively). The life of the sensor was 180 days in two of the DD and provided high satisfaction. This innovative device might be considered a future alternative for home glucose monitoring in DD.