Benjamim Ficial

Dr. Benjamim Ficial

Verona University Hospital
orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2013 in Journal of the American Society of Echocardiography
Verified
Journal Article
Open access
BFBenjamim Ficial
Benjamim Ficial
AFAnna E. Finnemore
Anna E. Finnemore
DCDavid J. Cox
David J. Cox
KBKathryn M. Broadhouse
Kathryn M. Broadhouse
APAnthony N. Price
Anthony N. Price
AGAlan M. Groves
Alan M. Groves
The echocardiographic assessment of circulatory function in sick newborn infants has the potential to improve patient care. However, measurements are prone to error and have not been sufficiently validated. Phase-contrast magnetic resonance imaging (MRI) provides highly validated measures of blood flow and has recently been applied to the newborn population. The aim of this study was to validate measures of left ventricular output and superior vena caval flow volume in newborn infants. Echocardiographic and MRI assessments were performed within 1 working day of each other in a cohort of newborn infants. Examinations were performed in 49 infants with a median corrected gestational age at scan of 34.43 weeks (range, 27.43-40 weeks) and a median weight at scan of 1,880 g (range, 660-3,760 g). Echocardiographic assessment of left ventricular output showed a strong correlation with MRI assessment (R(2) = 0.83; mean bias, -9.6 mL/kg/min; limits of agreement, -79.6 to +60.0 mL/kg/min; repeatability index, 28.2%). Echocardiographic assessment of superior vena caval flow showed a poor correlation with MRI assessment (R(2) = 0.22; mean bias, -13.7 mL/kg/min; limits of agreement, -89.1 to +61.7 mL/kg/min; repeatability index, 68.0%). Calculating superior vena caval flow volume from an axial area measurement and applying a 50% reduction to stroke distance to compensate for overestimation gave a slightly improved correlation with MRI (R(2) = 0.29; mean bias, 2.6 mL/kg/min; limits of agreement, -53.4 to +58.6 mL/kg/min; repeatability index, 54.5%). Echocardiographic assessment of left ventricular output appears relatively robust in newborn infant. Echocardiographic assessment of superior vena caval flow is of limited accuracy in this population, casting doubt on the utility of the measurement for diagnostic decision making.

27 April 2020 in Pediatric Pulmonology
Verified
Journal Article
Closed access
PDF file
ICIuri Corsini
Iuri Corsini
NPNiccolò Parri
Niccolò Parri
BFBenjamim Ficial
Benjamim Ficial
Carlo DaniCarlo Dani
Carlo Dani

26 May 2016 in Archives of Disease in Childhood - Fetal and Neonatal Edition
Verified
Journal Article
Closed access
BFBenjamim Ficial
Benjamim Ficial
EBElena Bonafiglia
Elena Bonafiglia
EPEzio M Padovani
Ezio M Padovani
MPMaria A Prioli
Maria A Prioli
AFAnna E Finnemore
Anna E Finnemore
AGAlan M Groves
Alan M Groves
Objective: To assess accuracy and repeatability of a modified echocardiographic approach to quantify superior vena cava (SVC) flow volume that uses a short-axis view to directly measure SVC area and a suprasternal view to measure flow velocity, both at the level of the right pulmonary artery. Setting: Three tertiary-level neonatal intensive care units. Design: This was a multicentre, prospective, observational study. Accuracy of the traditional and modified approach was first assessed by comparing echo measurements according to both techniques with Phase contrast MRI (PCMRI) assessments, in a cohort of 10 neonates. In a second cohort of 40 neonates, intraobserver scan–rescan repeatability and interobserver analysis–reanalysis repeatability were assessed by repeated SVC flow echo measurements, according to both techniques. Results: The traditional echocardiographic approach to assessment of SVC flow had a moderate agreement with PCMRI (r2 0.259), a scan–rescan intraobserver repeatability index (RI) of 37% (limits of agreement (LOA) −47/+51 mL/kg/min) and an interobserver analysis–reanalysis RI of 31% (LOA −38/+40 mL/kg/min). The modified approach showed a stronger agreement with PCMRI (r2 0.775), an improved intraobserver scan–rescan repeatability (RI 22%, LOA −24/+18 mL/kg/min) and improved interobserver analysis–reanalysis repeatability (RI 18%, LOA −18/+20 mL/kg/min). Conclusions: Echocardiographic assessment of SVC flow volume by tracing area from a short-axis view and measuring velocity–time integral from a suprasternal view offered an improvement in accuracy and repeatability, building on the traditional approach previously described.

28 March 2022 in Pediatric Pulmonology
Verified
Journal Article
Closed access
ICIuri Corsini
Iuri Corsini
BFBenjamim Ficial
Benjamim Ficial
MCMartina Ciarcià
Martina Ciarcià
LCLetizia Capasso
Letizia Capasso
FMFiorella Migliaro
Fiorella Migliaro
Carlo DaniCarlo Dani
Carlo Dani

8 July 2022 in Scientific Reports
Verified
Journal Article
Open access
PDF file
EBElena Bonafiglia
Elena Bonafiglia
Elena GussonElena Gusson
Elena Gusson
RLRosa Longo
Rosa Longo
BFBenjamim Ficial
Benjamim Ficial
MTMaria Giulia Tisato
Maria Giulia Tisato
GMGiorgio Marchini
Giorgio Marchini
This study investigates the impact of antenatal and postnatal infection or inflammation on the onset and progression of Retinopathy of Prematurity (ROP). We retrospectively collected clinical and demographic data of preterm infants with birth weight ≤ 1500 g or gestational age < 30 weeks admitted to the neonatal intensive care unit of Verona from 2015 to 2019. Uni- and multivariable analysis was performed to evaluate the potential effect of selected variables on the occurrence of any stage ROP and its progression to severe ROP, defined as ROP requiring treatment. Two hundred and eighty neonates were enrolled and 60 of them developed ROP (21.4%). Oxygen need for 28 days and late-onset sepsis (LOS) increased the risk of any grade ROP after adjusting for birth weight and gestational age (OR 6.35, 95% CI 2.14–18.85 and OR 2.49, 95% CI 1.04–5.94, respectively). Days of mechanical ventilation and of non-invasive ventilation increased the risk of progression to severe ROP after adjusting for birth weight and gestational age (OR 1.08, CI 1.02–1.14 and OR 1.06, CI 1.01–1.11, respectively). Exposure to infection with production of inflammatory mediators may contribute to increase the risk of ROP occurrence in very preterm neonates.

22 October 2019 in Italian Journal of Pediatrics
Verified
Journal Article
Open access
PDF file
ONOn Behalf of Study Group of Neonatal Cardiology of the Italian Society of Neonatology
On Behalf of Study Group of Neonatal Cardiology of the Italian Society of Neonatology
ICIuri Corsini
Iuri Corsini
BFBenjamim Ficial
Benjamim Ficial
SFStefano Fiocchi
Stefano Fiocchi
FSFederico Schena
Federico Schena
MSMarilena Savoia
Marilena Savoia
Background: Neonatologist performed echocardiography (NPE) has increasingly been used to assess the hemodynamic status in neonates. Aim of this survey was to investigate the utilization of NPE in Italian neonatal intensive care units (NICUs). Methods: We conducted an on-line survey from June to September 2017. A questionnaire was developed by the Italian neonatal cardiology study group and was sent to each Italian NICU. Results: The response rate was 77%. In 94% of Italian NICUs functional echocardiography was used by neonatologists, cardiologists or both (57, 15 and 28% respectively). All the respondents used NPE in neonates with patent ductus arteriosus and persistent pulmonary hypertension, 93% in neonates with hypotension or shock, 85% in neonates with perinatal asphyxia, 78% in suspicion of cardiac tamponade, and 73% for line positioning. In 30% of center, there was no NPE protocol. Structural echocardiography in stable and critically ill neonates was performed exclusively by neonatologists in 46 and 36% of center respectively. Conclusions: NPE is widely used in Italian NICUs by neonatologists. Structural echocardiography is frequently performed by neonatologists. Institutional protocols for NPE are lacking. There is an urgent need of a formal training process and accreditation to standardize the use of NPE.