Background: Respiratory distress (RD) is the most common neonatal illness. Lung ultrasound (LUS) is a technique previously tested in neonatal studies on RD, but literature regarding its routine clinical applicability is still lacking. Objective: To assess the concordance between LUS performed by neonatologists with different training levels and chest X-ray (CXR) for the diagnosis of RD in newborns during the first 24 h of life. Methods: We enrolled newborns with RD during the first 24 h of life. Patients underwent LUS and CXR. LUS and CXR diagnosis were compared to evaluate concordance. Twenty percent of patients received two LUS (one from an experienced and one from a novice sonographer) to calculate the interobserver agreement. The difference in time needed to reach a diagnosis with LUS and CXR, and from novice and expert operators, was measured. Results: We studied 124 patients; 134 diagnoses were reported. The concordance between LUS and CXR diagnosis was 91% (95% CI 86–96%) with a κ statistic of 0.88 (95% CI 0.81–0.94). The median time to diagnosis was shorter for LUS (9.5 min, IQR 5–15) than for CXR (50 min, IQR 33–64) (p < 0.0001). In 25/124 patients, LUS was performed by both novice and experienced sonographers with complete concordance. The median time to diagnosis was shorter for expert (9 min, IQR 5–15) than novice operators (15 min, IQR 10–20) (p < 0.0002). Conclusion: LUS and CXR have a high concordance in the differential diagnosis of neonatal RD in the first 24 h of life. LUS has a shorter operation time than CXR.
Background and Aim: Discordant results that demand clarification have been published on diagnostic lung ultrasound (LUS) signs of transient tachypnea of the neonate (TTN) in previous cross-sectional, single-center studies. This work was conducted to correlate clinical and imaging data in a longitudinal and multicenter fashion. Methods: Neonates with a gestational age of 34–40 weeks and presenting with TTN underwent a first LUS scan at 60–180 min of life. LUS scans were repeated every 6–12 h if signs of respiratory distress persisted. Images were qualitatively described and a LUS aeration score was calculated. Clinical data were collected during respiratory distress. Results: We enrolled 65 TTN patients. Thirty-one (47.6%) had a sharp echogenicity increase in the lower lung fields (the “double lung point” or DLP sign). On admission, there was no significant difference between patients with and without DLP in Silverman scores (4 ± 1.5 vs. 4 ± 2.1; p = 0.9) or LUS scores (7.6 ± 2.6 vs. 5.6 ± 3.8; p = 0.12); PaO2/FiO2 (249 ± 93 vs. 252 ± 125; p = 0.91). All initial LUS scans (performed at the onset of distress) and 99.5% of all scans showed a regular pleural line with no consolidation, with only 1 neonate showing consolidation in the follow-up scans. The Silverman and LUS scores were significantly correlated (rho = 0.27; p = 0.02). Conclusion: A regular pleural line with no consolidation is a consistent finding in TTN. The presence of a DLP is not essential for the LUS diagnosis of TTN. A semi-quantitative LUS score correlates well with the clinical course and could be useful in monitoring changes in lung aeration during TTN.
Many term and preterm infants are commonly supplemented with probiotics to prevent adverse effects of antibiotic administration and necrotizing enterocolitis and they are believed to be safe. However, the supplementation with Lactobacillus rhamnosus GG has been associated with the development of sepsis with a cause–effect relationship in six newborns and children. In this study, we report two further cases and discuss the emerging issue of probiotic supplementation safety in neonates. We conclude that physicians must be aware that supplementation with L. rhamnosus GG can cause sepsis in high-risk patients on rare occasions.
Background: Clinical and radiographic criteria are traditionally used to determine the need for surfactant therapy in preterm infants. Lung ultrasound is a bedside test that offers a rapid, radiation‐free, alternative to this approach.Objective: To conduct a systematic review and meta‐analysis to determine the accuracy of a lung ultrasound score (LUS) in identifying infants who would receive at least one surfactant dose. Secondary aims were to evaluate the predictive accuracy for ≥2 doses and the accuracy of a different image classification system based on three lung ultrasound profiles.Methods: PubMed, SCOPUS, Biomed Central, and the Cochrane library between January 2011 and December 2021 were searched. Full articles enrolling preterm neonates who underwent lung ultrasound to predict surfactant administration were assessed and analyzed following Preferred Reporting Items for Systematic Review and Meta‐Analysis Protocols (PRISMA‐P) and QUADAS‐2 guidelines.Results: Seven prospective studies recruiting 697 infants met the inclusion criteria. Risk of bias was generally low. Oxygen requirement, clinical and radiographic signs of respiratory distress syndrome were used as reference standards for surfactant replacement. The summary receiver operator characteristic (sROC) curve for LUS predicting first surfactant dose showed an area under the curve (AUC) = 0.88 (95% confidence interval [CI]: 0.82–0.91); optimal specificity and sensitivity (Youden index) were 0.83 and 0.81 respectively. Pooled estimates of sensitivity, specificity, diagnostic odds ratio, negative predictive value, and positive predictive value for LUS predicting the first surfactant dose were 0.89 (0.82–0.95), 0.86 (0.78–0.95), 3.78 (3.05–4.50), 0.92 (0.87–0.97), 0.79 (0.65–0.92). The sROC curve for the accuracy of Type 1 lung profile in predicting first surfactant dose showed an AUC of 0.88; optimal specificity and sensitivity were both 0.86. Two studies addressing the predictive accuracy of LUS for ≥2 surfactant doses had high heterogeneity and were unsuitable to combine in a meta‐analysis.Discussion: Despite current significant variation in LUS thresholds, lung ultrasound is highly predictive of the need for early surfactant replacement. This evidence was derived from studies with homogeneous patient characteristics and low risk of bias.