Piotr Pysz

Dr. Piotr Pysz

Medical University of Silesia, Katowice, Śląskie, Poland
orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
EOEustaquio Maria Onorato
Eustaquio Maria Onorato
FAFrancesco Alamanni
Francesco Alamanni
MMManuela Muratori
Manuela Muratori
GSGrzegorz Smolka
Grzegorz Smolka
WWWojtek Wojakowski
Wojtek Wojakowski
ABAntonio Luca Bartorelli
Antonio Luca Bartorelli
Between December 2014 and March 2021, 144 patients with aortic (Ao) or mitral (Mi) paravalvular leaks (PVLs) were enrolled at 21 sites in 10 countries. Safety data were available for 137 patients, who were included in the safety analysis fraction (SAF), 93 patients with Mi PVLs and 44 patients with Ao PVLs. The full analysis set (FAS) comprised 112 patients with available stratum (aortic/mitral leak) as well as baseline (BL), 180-day or later assessments (2 years). Procedural success (implantation of the device with a proper closure of the PVL, defined as reduction in paravalvular regurgitation of ≥one grade as assessed by echocardiography post implantation) was achieved in 91.3% of FAS patients with Mi PVLs and in 90.0% of those with Ao PVLs. The proportion of patients suffering from significant or severe heart failure (HF), classified as New York Heart Association (NYHA) class III/IV, decreased from 80% at baseline to 14.1% at 2-year follow-up (FAS). The proportion of FAS patients needing hemolysis-related blood transfusion decreased from 35.5% to 3.8% and from 8.1% to 0% in Mi patients and Ao patients, respectively. In total, 35 serious adverse events (SAEs) were reported in 27 patients (19.7%) of the SAF population. The SAEs considered possibly or probably related to the device included device embolization (three patients), residual leak (two patients) and vascular complication (one patient). During follow-up, 12/137 (8.8%) patients died, but none of the deaths was considered to be device-related. Patients implanted with the Occlutech Paravalvular Leak Device (PLD) showed long-lasting improvements in clinical parameters, including NYHA class and a reduced dependency on hemolysis-related blood transfusions.

30 January 2011 in The International Journal of Cardiovascular Imaging
Verified
Journal Article
Open access
PDF file
Katarzyna Mizia-StecKatarzyna Mizia-Stec
Katarzyna Mizia-Stec
PPPiotr Pysz
Piotr Pysz
MJMarek Jasiński
Marek Jasiński
TATomasz Adamczyk
Tomasz Adamczyk
ADAgnieszka Drzewiecka-Gerber
Agnieszka Drzewiecka-Gerber
MTMichał Tendera
Michał Tendera
Precise measurements of aortic complex diameters are essential for preoperative examinations of patients with aortic stenosis (AS) scheduled for aortic valve (AV) replacement. We aimed to prospectively compare the accuracy of transthoracic echocardiography (TTE), transoesophageal echocardiography (TEE) and multi-slice computed tomography (MSCT) measurements of the AV complex and to analyze the role of the multi-modality aortic annulus diameter (AAd) assessment in the selection of the optimal prosthesis to be implanted in patients surgically treated for degenerative AS. 20 patients (F/M: 3/17; age: 69 ± 6.5 years) with severe degenerative AS were enrolled into the study. TTE, TEE and MSCT including AV calcium score (AVCS) assessment were performed in all patients. The values of AAd obtained in the long AV complex axis (TTE, TEE, MSCT) and in multiplanar perpendicular imaging (MSCT) were compared to the size of implanted prosthesis. The mean AAd was 24 ± 3.6 mm using TTE, 26 ± 4.2 mm using TEE, and 26.9 ± 3.2 in MSCT (P = 0.04 vs. TTE). The mean diameter of the left ventricle out-flow tract in TTE (19.9 ± 2.7 mm) and TEE (19.5 ± 2.7 mm) were smaller than in MSCT (24.9 ± 3.3 mm, P < 0.001 for both). The mean size of implanted prosthesis (22.2 ± 2.3 mm) was significantly smaller than the mean AAd measured by TTE (P = 0.0039), TEE (P = 0.0004), and MSCT (P < 0.0001). The implanted prosthesis size correlated significantly to the AAd: r = 0.603, P = 0.005 for TTE, r = 0.592, P = 0.006 for TEE, and r = 0.791, P < 0.001 for MSCT. Obesity and extensive valve calcification (AV calcium score ≥ 3177Ag.U.) were identified as potent factors that caused a deterioration of both TTE and MSCT performance. The accuracy of AAd measurements in TEE was only limited by AV calcification. In multivariate regression analysis the mean value of the minimum and maximum AAd obtained in MSCT-multiplanar perpendicular imaging was an independent factor (r = 0.802, P < 0.0001) predicting the size of implanted prosthesis. In patients with AS echocardiography remains the main diagnostics tool in clinical practice. MSCT as a 3-dimentional modality allows for accurate measurement of entire AV complex and facilitates optimal matching of prosthesis size.

30 September 2021 in Polish Heart Journal
Verified
Journal Article
Open access
PDF file
PPPiotr Pysz
Piotr Pysz
RRRenata Rajtar-Salwa
Renata Rajtar-Salwa
GSGrzegorz Smolka
Grzegorz Smolka
Iacopo OlivottoIacopo Olivotto
Iacopo Olivotto
WWWojtek Wojakowski
Wojtek Wojakowski
PDPawel Petkow Dimitrow
Pawel Petkow Dimitrow
Current pharmacotherapy for hypertrophic cardiomyopathy (HCM) is not disease-specific and has suboptimal efficacy, often necessitating interventional treatment. EXPLORER-HCM was a phase 3, randomized, double-blind, placebo-controlled, multicenter clinical trial investigating the effects of mavacamten, a first-in-class selective cardiac myosin inhibitor, in patients with HCM, left ventricular outflow tract obstruction (LVOTO) and New York Heart Association (NYHA) class II or III symptoms. The primary endpoint was defined as either a ≥1.5 ml/kg/min increase in peak oxygen consumption (pVO₂) and ≥1 NYHA class reduction or a ≥3.0 ml/kg/min pVO2 increase without NYHA class worsening. Secondary endpoints evaluated changes in post-exercise LVOT gradient, pVO2, NYHA class, Kansas City Cardiomyopathy Questionnaire-Clinical Summary Score (KCCQ-CSS), and Hypertrophic Cardiomyopa-thy Symptom Questionnaire Shortness-of-Breath subscore (HCMSQ-SoB). A total of 251 patients were randomized to receiving mavacamten or placebo. The primary endpoint and all secondary endpoints were met significantly more frequently in the mavacamten arm versus placebo. The safety profile of mavacamten was similar to that of placebo. In conclusion, disease-specific treatment with mavacamten in patients with obstructive HCM led to reduced LVOTO and improvement in both objective functional parameters and patient-related health status.

1 October 2013
Verified
Journal Article
Closed access
GSGrzegorz Smolka
Grzegorz Smolka
PPPiotr Pysz
Piotr Pysz
MJMarek Jasinski
Marek Jasinski
RGRadosław Gocoł
Radosław Gocoł
WDWojciech Domaradzki
Wojciech Domaradzki
ZGZbigniew Gąsior
Zbigniew Gąsior

1 January 2019 in Advances in Interventional Cardiology
Verified
Journal Article
Open access
PPPiotr Pysz
Piotr Pysz
MKMichał Kozłowski
Michał Kozłowski
MMMagdalena Malczewska
Magdalena Malczewska
EAEliza Adamczyk-Filipek
Eliza Adamczyk-Filipek
WWWojciech Wojakowski
Wojciech Wojakowski
GSGrzegorz Smolka
Grzegorz Smolka
Introduction Transcatheter paravalvular leak closure (TPVLC) has become a well-established method of treatment for patients with paravalvular leak (PVL) causing heart failure or significant hemolysis. Nonetheless, the method of optimal PVL sizing and subsequent device choice requires...

23 July 2012 in Catheterization and Cardiovascular Interventions
Verified
Journal Article
Closed access
PDF file
GSGrzegorz Smolka
Grzegorz Smolka
PPPiotr Pysz
Piotr Pysz
MJMarek Jasinski
Marek Jasinski