Eustaquio Maria Onorato

Dr. Eustaquio Maria Onorato

Centro Cardiologico Monzino, Milan, Lombardy, Italy
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 December 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
SHSebastien Hascoet
Sebastien Hascoet
GSGrzegorz Smolka
Grzegorz Smolka
TKTeoman Kilic
Teoman Kilic
Reda IbrahimReda Ibrahim
Reda Ibrahim
EOEustaquio Maria Onorato
Eustaquio Maria Onorato
BGBenoit Gerardin
Benoit Gerardin
Prosthetic paravalvular leaks (PVLs) are associated with congestive heart failure and hemolysis. Surgical PVL closure carries high risks. Transcatheter implantation of occluding devices in PVL is a lower risk but challenging procedure. Of the available devices, only two have been specifically approved in Europe for transcatheter PVL closure (tPVLc): the Occlutech® Paravalvular Leak Device (PLD) and Amplatzer™ ParaValvular Plug 3 (AVP 3). Here, we review the various tools and devices used for tPVLc, based on three observational registries including 748 tPVLc procedures performed in 2005–2021 at 33 centres in 11 countries. In this case, 12 registry investigators with over 20 tPVLc procedures each described their practical tips and tricks regarding imaging, approaches, delivery systems, and devices. They considered three-dimensional echocardiography to be the cornerstone of PVL assessment and procedure guidance. Anterograde trans-septal mitral valve and retrograde aortic approaches were used in most centres, although some investigators preferred the transapical approach. Hydrophilic-coated low-profile sheaths were used most often for device deployment. The AVP 3 and PLD devices were chosen for 89.0% of procedures. Further advances in design and materials are awaited. These complex procedures require considerable expertise, and experience accumulated over a decade has no doubt contributed to improve practices.

Verified
Journal Article
Open access
PDF file
EOEustaquio Maria Onorato
Eustaquio Maria Onorato
FAFrancesco Alamanni
Francesco Alamanni
MMManuela Muratori
Manuela Muratori
GSGrzegorz Smolka
Grzegorz Smolka
WWWojtek Wojakowski
Wojtek Wojakowski
ABAntonio Luca Bartorelli
Antonio Luca Bartorelli
Between December 2014 and March 2021, 144 patients with aortic (Ao) or mitral (Mi) paravalvular leaks (PVLs) were enrolled at 21 sites in 10 countries. Safety data were available for 137 patients, who were included in the safety analysis fraction (SAF), 93 patients with Mi PVLs and 44 patients with Ao PVLs. The full analysis set (FAS) comprised 112 patients with available stratum (aortic/mitral leak) as well as baseline (BL), 180-day or later assessments (2 years). Procedural success (implantation of the device with a proper closure of the PVL, defined as reduction in paravalvular regurgitation of ≥one grade as assessed by echocardiography post implantation) was achieved in 91.3% of FAS patients with Mi PVLs and in 90.0% of those with Ao PVLs. The proportion of patients suffering from significant or severe heart failure (HF), classified as New York Heart Association (NYHA) class III/IV, decreased from 80% at baseline to 14.1% at 2-year follow-up (FAS). The proportion of FAS patients needing hemolysis-related blood transfusion decreased from 35.5% to 3.8% and from 8.1% to 0% in Mi patients and Ao patients, respectively. In total, 35 serious adverse events (SAEs) were reported in 27 patients (19.7%) of the SAF population. The SAEs considered possibly or probably related to the device included device embolization (three patients), residual leak (two patients) and vascular complication (one patient). During follow-up, 12/137 (8.8%) patients died, but none of the deaths was considered to be device-related. Patients implanted with the Occlutech Paravalvular Leak Device (PLD) showed long-lasting improvements in clinical parameters, including NYHA class and a reduced dependency on hemolysis-related blood transfusions.

26 July 2021 in World Journal of Cardiology
Verified
Journal Article
Open access
EOEustaquio Maria Onorato
Eustaquio Maria Onorato
Large eustachian valve fostering paradoxical thromboembolism: passive bystander or serial partner in crime?

Verified
Journal Article
Open access
PDF file
XFXavier Freixa
Xavier Freixa
RGRami Gabani
Rami Gabani
PCPedro Luis Cepas-Guillen
Pedro Luis Cepas-Guillen
EFEduardo Flores-Umanzor
Eduardo Flores-Umanzor
RERodrigo Estévez-Loureiro
Rodrigo Estévez-Loureiro
EOEustaquio Maria Onorato
Eustaquio Maria Onorato
Moderate to severe paravalvular-leak (PVL) regurgitation after surgical aortic-valve replacement or after transcatheter valve implantation represents a well-known complication associated with symptoms related to heart failure, hemolysis, or both in patients with multiple comorbidities and with poor prognostic outcomes. The transcatheter closure of aortic paravalvular leaks (APVLs) is currently considered a valid alternative to cardiac surgery. Nevertheless, careful patient selection, optimal cardiac imaging for intraprocedural guidance, and expert operators are key for success. Although technically demanding, particularly in APVLs after transcatheter valve implantation, catheter-based closure is an effective, less invasive, and often the only option for high-risk patients with symptomatic PVL regurgitation.

5 September 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
SESalvatore Evola
Salvatore Evola
ECEmmanuele Antonio Camarda
Emmanuele Antonio Camarda
OTOreste Fabio Triolo
Oreste Fabio Triolo
DADaniele Adorno
Daniele Adorno
ADAlessandro D'Agostino
Alessandro D'Agostino
EOEustaquio Maria Onorato
Eustaquio Maria Onorato
Introduction: The aim of this study was to assess clinical outcomes and quality of life after PFO closure in patients with previous stroke/TIA of undetermined cause and in patients with other complex PFO-associated clinical conditions. Methods: Between July 2009 and December 2019 at our University Cardiology Department, 118 consecutive patients underwent a thorough diagnostic work-up including standardized history taking, clinical evaluation, full neurological examination, screening for thrombophilia, brain magnetic resonance imaging (MRI), ultrasound–Doppler sonography of supra-aortic vessels and 24 h ECG Holter monitoring. Anatomo-morphological evaluation using 2D transthoracic/transesophageal echocardiography (TTE/TEE) color Doppler and functional assessment using contrast TTE (cTTE) in the apical four-chamber view and contrast transcranial Doppler (cTCD) using power M-mode modality were performed to verify the presence, location and amount of right-to-left shunting via PFO or other extracardiac source. Completed questionnaires based on the Quality-of-Life Short Form-36 (QoL SF-36) and Migraine Disability Assessment (MIDAS) were obtained from the patients before PFO closure and after 12 months. Contrast TTE/TEE and cTCD were performed at dismission, 1, 6 and 12 months and yearly thereafter. Brain MRI was performed at 1-year follow-up in 54 patients. Results: Transcatheter PFO closure was performed in 106 selected symptomatic patients (mean age 41.7 ± 10.7 years, range 16–63, 65% women) with the following conditions: ischemic stroke (n = 23), transient ischemic attack (n = 22), peripheral and coronary embolism (n = 2), MRI lesions without cerebrovascular clinical events (n = 53), platypnea–orthodeoxia (n = 1), decompression sickness (n = 1) and refractory migraine without ischemic cerebral lesions (n = 4). The implanted devices were Occlutech Figulla Flex I/II PFO (n = 99), Occlutech UNI (n = 3), Amplatzer PFO (n = 3) and CeraFlex PFO occluders (n = 1). Procedures were performed under local anesthesia and rotational intracardiac monitoring (Ultra ICE) alone. The devices were correctly implanted in all patients. The mean fluoroscopy time was 15 ± 5 min (range = 10–45 min) and the mean procedural time was 55 ± 20 min (range = 35–90 min). The total occlusion rate at follow-up (mean 50 months, range 3–100) was 98.1%. No recurrent neurological events were observed in the long-term follow-up. Conclusions: The data collected in this study demonstrate that percutaneous PFO closure is a safe and effective procedure, showing long-term prevention of recurrent cerebrovascular events, significant reduction in migraine symptoms and substantial improvement in quality of life.

28 February 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
AZAleksejus Zorinas
Aleksejus Zorinas
DZDiana Zakarkaite
Diana Zakarkaite
VJVilius Janušauskas
Vilius Janušauskas
Donatas AustysDonatas Austys
Donatas Austys
LPLina Puodziukaite
Lina Puodziukaite
EOEustaquio Maria Onorato
Eustaquio Maria Onorato
Widespread catheter-based interventions for structural heart disease have overtaken the treatment of paravalvular leaks (PVL). Multimodality imaging techniques play a crucial role in accurate diagnosis, procedure planning and performance. However, PVL closure is often technically challenging due to the complex anatomy of the defects and their relation to surrounding anatomical structures. The application of echocardiography and fluoroscopy imaging fusion (EFF) may simplify challenging imaginative three-dimensional reconstruction of the intracardiac anatomy and facilitate the procedure. To master new technology, personnel must make cognitive changes, overcome a learning curve, and obtain adequate theoretical knowledge. Main aim of this manuscript is to present basic recommendations for EFF application in practice, alongside, each scenario is supported by technically challenging clinical examples. We may conclude that our manuscript may provide useful information for physicians on EEF application in clinical practice.