Numerical calculation of conjugate heat transfer was carried out to study the effect of combined film and swirl cooling at the leading edge of a gas turbine vane with a cooling chamber inside. Two cooling chambers (C1 and C2 cases) were specially designed to generate swirl in the chamber, which could enhance overall cooling effectiveness at the leading edge. A simple cooling chamber (C0 case) was designed as a baseline. The effects of different cooling chambers were studied. Compared with the C0 case, the cooling chamber in the C1 case consists of a front cavity and a back cavity and two cavities are connected by a passage on the pressure side to improve the overall cooling effectiveness of the vane. The area-averaged overall cooling effectiveness of the leading edge ( ) was improved by approximately 57%. Based on the C1 case, the passage along the vane was divided into nine segments in the C2 case to enhance the cooling effectiveness at the leading edge, and was enhanced by 75% compared with that in the C0 case. Additionally, the cooling efficiency on the pressure side was improved significantly by using swirl-cooling chambers. Pressure loss in the C2 and C1 cases was larger than that in the C0 case.
Flow separation and different kinds of stall flows occur under low load conditions for steam turbine last stage blades. In order to delay the flow separation and increase turbine power production, we applied suction side tubercles on steam turbine low-pressure last stage blades in the present study. The amplitude, wavelength, position, and thickness were considered as our design variables. We used the orthogonal test method (OTM) to generate modified blades with different tubercle variables that were then numerically simulated by a three-dimensional computational fluid dynamics (CFD) analysis. The blade axial torque of the nine modified tests was compared with the original blade. The results showed that the application of bionic tubercles on the suction side of the steam turbine blade is a promising solution to improve the blade axial torque for all modified tests with a maximum increase of 33.32% due to the turbulent vortices generated by bionic tubercles.
Low-grade renewable energy possesses large reserves and a wide distribution in the environment, but it is far from fully exploited due to the high cost–income ratio when using traditional convertors. A fluid-induced-vibration-based flow energy convertor with a low-cost bent plate as an oscillator is proposed to achieve better energy converting performance for low-grade flow energy conversion. The energy extraction performance and dynamic response of the bent plate are assessed numerically. The results demonstrate that the prescribed single-DOF (degree of freedom) bent plate can reach the maximum efficiency of 29.6% and power coefficient of 2.36 at the relative plunging amplitude of 3.5, while the double-DOF bent plate achieves a maximum efficiency of 37.3% and power coefficient of 1.42 at a smaller amplitude of 1.4. It is discovered that the adoption of pitching motion can help to control the variation pattern of the effective AOA (angle of attack), while the camber of the bent plate also regulates the effective AOA from the geometrical respect. The FIV-based single-DOF convertor can achieve an energy converting efficiency of 29.3% and approach the ideal sinusoidal motion trajectory closely, indicating that the optimal active motion mode can be realized by the passive motion mode with the appropriate choice of the dynamic parameters.
During the installation process, most of 1000MW-class nuclear power steam turbines will undergo certain deformations due to their own big size and heavy weight, which will change seal clearances of steam passage. If the clearance is too big, it will lead leakage loss and affect steam turbine’s efficiency. If the clearance is too small, it may cause the rubbing fault between moving