Catalin George POPOVICI

Dr. Catalin George POPOVICI


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 November 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Sebastian Valeriu HudisteanuSebastian Valeriu Hudisteanu
Sebastian Valeriu Hudisteanu
FTFlorin-Emilian Turcanu
Florin-Emilian Turcanu
Nelu Cristian CherechesNelu Cristian Chereches
Nelu Cristian Chereches
CPCatalin George POPOVICI
Catalin George POPOVICI
TETurcanu EMILIAN
Turcanu EMILIAN
IHIuliana Hudisteanu
Iuliana Hudisteanu
This paper presents a numerical model regarding the passive cooling of PV panels through perforated and non-perforated heat sinks. A typical PV panel was studied in a fixed position, tilted at 45 degrees from the horizontal with the wind direction towards its backside. A challenging approach was used in order to calibrate the base case of the numerical model according to the NOCT conditions. Further validation of the accuracy of the numerical simulation consisted of a comparison between the results obtained for the base case, or heat sink, with horizontal non-perforated fins and the experiments presented in the literature. Six types of heat sink attached to the backside of the PV panel were numerically studied. The analyzed configurations focused on heat sinks with both perforated and non-perforated fins that were distributed horizontally and vertically. The CFD simulation was also conducted by modeling the air volume around the PV panel in real wind conditions. The main output parameters were the average temperature and the convective heat transfer coefficient on the front and back of the PV panel. The most important effect of cooling was achieved in low wind conditions and high levels of solar radiation. For vair = 1 m/s, G = 1000 W/m2 and ambient temperature tair = 35 °C, the percentage of maximum power production achieved 83.33% for the base case, while in the best cooling scenario it reached 88.74%, assuring a rise in the power production of 6.49%.

Larisa AnghelLarisa Anghel
Larisa Anghel
CPCatalin George POPOVICI
Catalin George POPOVICI
CRISTIAN STATESCUCRISTIAN STATESCU
CRISTIAN STATESCU
RSRadu Andy Sascau
Radu Andy Sascau
MVMarina Verdeș
Marina Verdeș
FTFlorin-Emilian Turcanu
Florin-Emilian Turcanu
At the end of 2019, a variation of a coronavirus, named SARS-CoV-2, has been identified as being responsible for a respiratory illness disease (COVID-19). Since ventilation is an important factor that influences airborne transmission, we proposed to study the impact of heating, ventilation and air-conditioning (HVAC) with a variable air volume (VAV) primary air system, on the dispersion of infectious aerosols, in a cardiac intensive care unit, using a transient simulation with computational fluid dynamics (CFD), based on the finite element method (FEM). We analyzed three scenarios that followed the dispersion of pathogen carrying expiratory droplets particles from coughing, from patients possibly infected with COVID-19, depending on the location of the patients in the intensive care unit. Our study provides the mechanism for spread of infectious aerosols, and possibly of COVID-19 infection, by air conditioning systems and also highlights important recommendations for disease control and optimization of ventilation in intensive care units, by increasing the use of outdoor air and the rate of air change, decreasing the recirculation of air and using high-efficiency particulate air (HEPA) filters. The CFD-FEM simulation approach that was applied in our study could also be extended to other targets, such as public transport, theaters, philharmonics and amphitheaters from educational units.

26 September 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Sebastian Valeriu HudisteanuSebastian Valeriu Hudisteanu
Sebastian Valeriu Hudisteanu
FTFlorin-Emilian Turcanu
Florin-Emilian Turcanu
Nelu Cristian CherechesNelu Cristian Chereches
Nelu Cristian Chereches
CPCatalin George POPOVICI
Catalin George POPOVICI
TETurcanu EMILIAN
Turcanu EMILIAN
IHIuliana Hudisteanu
Iuliana Hudisteanu
The numerical modeling of the effect of wind direction and velocity over the air cooling of PV panels with heat sinks is realized. During the study, a random PV panel with typical characteristics was analyzed for three different wind directions—towards its back, towards its front and from the side. The analysis was realized on a fixed PV panel, oriented to the south, with an inclination of 45 degrees from the horizontal position. The accuracy of the numerical simulation was achieved by comparison with the experimental studies presented in the literature and by comparing the NOCT conditions. The numerical study is focused on different types of heat sinks attached to a typical PV panel. The fins were distributed both horizontally and vertically. A challenging task consisted in simulation of the real wind conditions around the PV panel by taking into account the entire air domain. The simulations were realized for air velocity vair from 1 m/s to 5 m/s, solar radiation of G = 1000 W/m2 and ambient temperature tair = 35 °C. The output parameters analyzed were the average temperature of PV panels and their power production. Although the lowest temperatures were achieved for the back wind, the cooling effect was more intense for the side wind. The other direction studied also determined the cooling of PV panels. The passive cooling solutions analyzed introduced a rise of maximum power production between 1.85% and 7.71% above the base case, depending on the wind direction and velocity.

20 December 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MCMonica Chereches
Monica Chereches
Nelu Cristian CherechesNelu Cristian Chereches
Nelu Cristian Chereches
ACAdrian Alexandru Ciobanu
Adrian Alexandru Ciobanu
Sebastian Valeriu HudisteanuSebastian Valeriu Hudisteanu
Sebastian Valeriu Hudisteanu
FTFlorin-Emilian Turcanu
Florin-Emilian Turcanu
CPCatalin George POPOVICI
Catalin George POPOVICI
In the context of energy conservation and sustainable development, building design should take into account the energy efficiency criteria by using renewable energy sources. Double-skin facades (DSF) represent innovative energy-efficient techniques that have gained increasing interest worldwide. The present study reports the results of an experimental campaign performed on a full-scale double-skin façade using the in-situ measurement methodology. The thermodynamic behavior of the façade is studied under real exterior climatic conditions in Romania in hot and cold seasons, and performance indicators in terms of pre-heating efficiency and dynamic insulation efficiency were determined. Three summer periods are analyzed corresponding to the outdoor air curtain scenario for three ventilation modes in naturally or mechanically ventilated single-story DSF. Results revealed that the third ventilation scenario, which combines horizontal and vertical openings, gives the best efficiency of 71.3% in the double skin façade functioning. During the cold season, the channel façade behaved like a thermal buffer between the building and the exterior air, ensuring the thermal energy for partial or integral heating of the building.

2 June 2020 in Energies
Verified
Journal Article
Open access
PDF file
FTFlorin-Emilian Turcanu
Florin-Emilian Turcanu
CPCatalin George POPOVICI
Catalin George POPOVICI
MVMarina Verdeș
Marina Verdeș
VCVasilică Ciocan
Vasilică Ciocan
Sebastian Valeriu HudisteanuSebastian Valeriu Hudisteanu
Sebastian Valeriu Hudisteanu
Background: The aim of our study was to identify an optimal heating system for the analyzed church. We also evaluated the energy consumption of the existing system and of those proposed in order to choose the best heating system. Methods: We analyzed the current existing heating system, a mixed system (static heaters and hot air heating) in a Romanian heritage church, build in the 16th century, and we compared it with an underfloor heating system that has been mentioned in the literature as an alternative for church heating. We used a computational fluid dynamics (CFD) analysis of the indoor climate with two turbulence models (k-ε and k-ω). Results: Comparing the two heating systems through boxplot graphs, we could highlight pertinent conclusions regarding the temperatures and velocities of the measured air currents. Thus, of all the heating systems, the underfloor heating had the lowest temperatures, but the highest air velocities, in the churchgoers area, especially under the towers zone. Conclusions: We observed that the underfloor heating system was more efficient than the existing heating system (static heaters and hot air heating), ensuring heritage conservation and high thermal comfort to the churchgoers.

9 May 2022 in Materials
Verified
Journal Article
Open access
PDF file
AAAna-Diana Ancas
Ana-Diana Ancas
FTFlorin-Emilian Turcanu
Florin-Emilian Turcanu
TETurcanu EMILIAN
Turcanu EMILIAN
Sebastian Valeriu HudisteanuSebastian Valeriu Hudisteanu
Sebastian Valeriu Hudisteanu
Nelu Cristian CherechesNelu Cristian Chereches
Nelu Cristian Chereches
MPMihai Profire
Mihai Profire
Globally, there are several critical infrastructure networks (water and gas networks) whose disruption or destruction would significantly affect the maintenance of vital societal functions, such as the health, safety, security, and social or economic well-being of people. They would also have significant local, regional, and national impacts as a result of the inability to maintain those functions, and would have similar cross-border effects. The main objective of this article is to investigate by comparative numerical studies the structural response of three types of buried pipes made of different materials, primarily steel, concrete, and high-density polyethylene, resulting from the impact of the environment through exceptional external actions, such as explosions at the surface of the land in the vicinity of the laying areas. The dynamic transient analysis of the equation of motion with the application of the explicit integration procedure was performed with the ANSYS numerical simulation program. This study allows designers to solve complex problems related to the quality of the laying ground of water networks to canals. The knowledge accumulated gives us the possibility to correctly specify the optimal economic and technical value of the ratio between the laying depth of pipes and their diameter, the importance of the radius ratio of the pipe and the thickness of its wall, and, importantly, the improvement of the quality of the foundation ground. Following the results obtained, it is estimated that the optimal economic and technical value of the ratio between the laying depth of the pipes (H) and their diameter (D) is 3, regardless of the material from which the pipe is made.