This paper presents a numerical model regarding the passive cooling of PV panels through perforated and non-perforated heat sinks. A typical PV panel was studied in a fixed position, tilted at 45 degrees from the horizontal with the wind direction towards its backside. A challenging approach was used in order to calibrate the base case of the numerical model according to the NOCT conditions. Further validation of the accuracy of the numerical simulation consisted of a comparison between the results obtained for the base case, or heat sink, with horizontal non-perforated fins and the experiments presented in the literature. Six types of heat sink attached to the backside of the PV panel were numerically studied. The analyzed configurations focused on heat sinks with both perforated and non-perforated fins that were distributed horizontally and vertically. The CFD simulation was also conducted by modeling the air volume around the PV panel in real wind conditions. The main output parameters were the average temperature and the convective heat transfer coefficient on the front and back of the PV panel. The most important effect of cooling was achieved in low wind conditions and high levels of solar radiation. For vair = 1 m/s, G = 1000 W/m2 and ambient temperature tair = 35 °C, the percentage of maximum power production achieved 83.33% for the base case, while in the best cooling scenario it reached 88.74%, assuring a rise in the power production of 6.49%.
Photovoltaic/thermal (PV/T) systems are innovative cogeneration systems that ensure the cooling of photovoltaic (PV) backside and simultaneous production of electricity and heat. However, an effective cooling of the PV back is still a challenge that affects electrical and thermal performance of the PV/T system. In the present work, a PV/T numerical model is developed to simulate the heat flux based on energy balance implemented in MATLAB software. The numerical model is validated through the comparison of the three-layer PV model with the NOCT model and tested under the operation conditions of continental temperate climate. Moreover, the effect of velocity and water film thickness as important flow parameters on heat exchange and PV/T production is numerically investigated. Results revealed that the PV model is in good agreement with the NOCT one. An efficient heat transfer is obtained while increasing the velocity and water film thickness with optimal values of 0.035 m/s and 7 mm, respectively, at an inlet temperature of 20 °C. The PV/T system ensures a maximum thermal power of 1334.5 W and electrical power of 316.56 W (258.8 W for the PV). Finally, the comparison between the PV and PV/T system under real weather conditions showed the advantage of using the PV/T.
The numerical modeling of the effect of wind direction and velocity over the air cooling of PV panels with heat sinks is realized. During the study, a random PV panel with typical characteristics was analyzed for three different wind directions—towards its back, towards its front and from the side. The analysis was realized on a fixed PV panel, oriented to the south, with an inclination of 45 degrees from the horizontal position. The accuracy of the numerical simulation was achieved by comparison with the experimental studies presented in the literature and by comparing the NOCT conditions. The numerical study is focused on different types of heat sinks attached to a typical PV panel. The fins were distributed both horizontally and vertically. A challenging task consisted in simulation of the real wind conditions around the PV panel by taking into account the entire air domain. The simulations were realized for air velocity vair from 1 m/s to 5 m/s, solar radiation of G = 1000 W/m2 and ambient temperature tair = 35 °C. The output parameters analyzed were the average temperature of PV panels and their power production. Although the lowest temperatures were achieved for the back wind, the cooling effect was more intense for the side wind. The other direction studied also determined the cooling of PV panels. The passive cooling solutions analyzed introduced a rise of maximum power production between 1.85% and 7.71% above the base case, depending on the wind direction and velocity.
The present study analyses the effect of solar protection arrangements on thermo-aeraulic regime inside a double-glazed facade coating (DFC), forced ventilated channel and under imposed working conditions. The facade has been considered being with “full South” guidance, exposed to normal solar radiation, with constant intensity. The “Venetian blinds” protection type has been investigated in optimum assumptions on the basis of previous researches [9], with regard to its positioning at 1/4th of the width of the channel, near exterior glazing and forced ventilation, under constant flow rate of 1260 m3/h. The opening angle of the blinds, as the sole variable parameter, has been amended in succession between 0° and 90°. Solar protection influence analysis has been carried out by numerical simulation, with the specialized computing program ANSYS-Fluent, laying down, for each opening angle of blinds, variation diagrams of air streams temperatures and velocity along the width and along front panel channels
1 April 2023 in Journal of Applied Engineering Sciences
The 3D model of a building was built to analyze the scene of a fire with reference to the real situation. The process of evolution of a fire was simulated with FDS. The evolution time of the fire, the degree of danger, the temperature as well as the visibility was analyzed. Architectural solutions that could be considered for the prevention and evolution of fire in the presented situations were also analyzed. The results of the simulations in the proposed scenarios showed that solutions could be found to prevent the spread of fire. The results of the study provide a real base for improving the evacuation conditions and limiting the damage caused by fire in single-family buildings.
The use of plant ash as a sustainable cementitious material in concrete composition is a widely researched subject in the construction domain. A plant studied so far more for its thermal insulation properties, sunflower, was analyzed in this study with regard to its ash effects on the concrete composition. The present research aimed to analyze the effects of a 2.5%, 5%, 7.5%, 10%, 15%, 20%, or 30% volume replacement of cement by sunflower stalk ash (SA), a sustainable cementitious material, on the concrete compressive strength at 28 days and three months, the flexural and splitting tensile strengths, the resistance to repeated freeze–thaw cycles, and the resistance to chemical attack of hydrochloric acid. The elementary chemical composition of the SA and the composites was included also. According to the experimental results, SA decreased the values of the compressive and tensile strength of the concrete, but it improved the concrete behavior under repeated freeze–thaw cycles and under the action of hydrochloric acid. A percent of 10% of SA led to a much more pronounced development of compressive strength over time than conventional concrete (26.6% versus 12%).