The aim of this study was to investigate the role of the flat-designed surface in improving the resistance to cyclic fatigue by comparing heat-treated F-One (Fanta Dental, Shanghai, China) nickel–titanium (NiTi) rotary instruments and similar prototypes, differing only by the absence of the flat side. The null hypothesis was that there were no differences between the two tested instruments in terms of cyclic fatigue lifespan. A total of 40 new NiTi instruments (20 F-One and 20 prototypes) were tested in the present study. The instruments were rotated with the same speed (500 rpm) and torque (2 N) using an endodontic motor (Elements Motor, Kerr, Orange, CA, USA) in the same stainless steel, artificial canal (90° angle of curvature and 5 mm radius). A Wilcoxon–Mann–Whitney test was performed to assess the differences in terms of time to fracture and the length of the fractured segment between the flat- and non-flat-sided instruments. Significance was set at p = 0.05. The differences in terms of time to fracture between non-flat and flat were statistically significant (p < 0.001). In addition, the differences in terms of fractured segment length were statistically significant (p = 0.034). The results of this study highlight the importance of flat-sided design in increasing the cyclic fatigue lifespan of NiTi rotary instruments.
The aim of this study was to evaluate the influence of implant scanbody (ISB) wear on the accuracy of digital impression for complete-arch. A polymethylmethacrylate (PMMA) edentulous mandibular model with four internal hexagonal interlocking conical connections was scanned with an extraoral optical scanner to achieve a reference file. Four cylindrical polyetheretherketone (PEEK) ISBs were scanned 30 times with IOS, and the test files were aligned to the reference file with a best-fit algorithm. For each analog linear (ΔX, ΔY and ΔZ-axis) and angular deviations (ΔANGLE) were assessed. Euclidean distance (ΔEUC) was calculated from the linear deviation, reporting a mean of 82 µm (SD 61) ranging from 8 to 347 µm. ΔANGLE error mean was 0.33° (SD 0.20), ranging from 0.02 to 0.92°. From a multivariate analysis, when ΔEUC was considered as a response variable, a significant influence of ISB wear by scan number in interaction to position for implant 3.6 was identified (p < 0.0001); when ΔANGLE was considered as a response variable, a significant effect of position 3.6 was recorded ((p < 0.0001). The obtained results showed that the ISB wear negatively influenced the accuracy of IOS, suggesting that ISB base wear could be detrimental for the seating of ISBs on angulated implants.
(1) Background: BioHPP® (Bredent, UK) is a partially crystalline poly ether ether ketone (PEEK) that is strengthened using ceramic. PEEK and its various formulations represent a very interesting alternative, and has been in-depth with its literature in recent years; (2) Methods: A PubMed and Scopus search for the term “BioHPP” yielded 73 results and 42 articles which were included in this short review. Considering the scarce literature on the subject, each article was considered in this review; (3) Results: the articles analyzed are very recent, all published in the last 5 years. Their clinical evaluation of BioHPP® highlights many positive aspects, and few articles have highlighted critical issues in its multiple clinical applications; (4) Conclusions: this material is not only extremely interesting for the future, but possesses characteristics suitable for clinical application today, for endocrowns, small adhesive bridges, temporary prostheses and for immediate loads on implant restorations. The excellent aesthetics and the possibility of simple reprocessing of the restorations made with this material invite its clinical application.
The use of pterygoid implants can be an attractive alternative to sinus bone grafting in the treatment of posterior atrophic maxilla. This technique has not been widely used because of the difficulty of the surgical access, the presence of vital structures, and the prosthetic challenges. The use of dynamic computer aided implantology (DCAI) allows the clinician to utilize navigation dental implant surgery, which allows the surgeon to follow the osteotomy site and implant positioning in real time. A total of 14 patients (28 pterygoid implants and 56 intersinusal implants) were enrolled in the study for a full arch implant prosthetic rehabilitation (4 frontal implants and 2 pterygoids implants), using a dynamic navigation system. The reported accuracy of pterygoid implants inserted using DCAI was 0.72 mm at coronal point, 1.25 mm at apical 3D, 0.66 mm at apical depth, and 2.86° as angular deviation. The use of pterygoid implants in lieu of bone grafting represents a valid treatment opportunity to carry out a safe, accurate, and minimally invasive surgery, while reducing treatment time and avoiding cantilevers for a full implant prosthetic rehabilitation of the upper arch.
New minimally invasive endodontic cavities have been described and proposed to preserve dentin (and enamel) through strategic access, including point endodontic access cavity (PEAC). There is no consensus to what extent PEAC contributes to tooth’s resistance to fracture, because there is no agreement on how PEAC should be performed. The purpose of the present study is to describe and classify four different types of PEACs and to examine if a dynamic navigation system /DNS) could allow planning and precisely executing these cavities in vitro. Forty TrueTooth TM Replica # 3-001 models, were randomly divided into four identical groups of ten and scanned using a cone bean computed tomography (OP-Maxio 300, Instrumentarium-Kavo, Finland). Then, four different access cavities were planned and performed by using DNS (Navident dynamic navigation system, ClaroNav, Toronto, ON, Canada). For each tooth, a different PEAC was designed to obtain endodontic access to the main mesio-buccal canal (MB1), resulting in a different location of the entry point on the occlusal surface of the tooth. Precision was evaluated by comparing deviation in the inclinations between the planned and real cavity. Data were recorded and statistically analyzed. DNS allowed preparation of minimally invasive “straight line” cavities, with some differences in the accuracy.
Objectives: To evaluate the cleaning efficacy of different irrigation activation techniques in removing smear layers from root canals. Materials and methods: Ninety lower premolars with straight root canals were assigned to six experimental groups (n = 15 each): control group, conventional irrigation, passive ultrasonic activation (PUI), distilled water laser-activated irrigation (LAI), PulpSucker irrigation, and iVac irrigation. Each canal was shaped to size 30/04 and irrigated with 5% NaOCl. The final rinse was performed according to the experimental group. After chemo-mechanical procedures, the teeth were split longitudinally and subjected to scanning electron microscopic (SEM) analysis for each root canal third (coronal, middle, and apical). The presence of smear layer was evaluated using a 5-grade scoring system at 500× and 1000× magnification. Following the Shapiro-Wilk test, data were statistically analyzed using the nonparametric Kruskal-Wallis test, followed by the post-hoc Dunn test with Bonferroni correction (α = 5%), to compare the effectiveness of smear layer removal. The Friedman test and post-hoc Wilcoxon signed-rank test with Bonferroni correction (α = 5%) were performed to assess significant differences in smear layer removal among the different tooth thirds. Results: Activated irrigation techniques significantly outperformed conventional irrigation (p <.05), with the iVac technique demonstrating the best results in smear layer removal in the apical third. LAI and PUI showed comparable results across all tooth thirds. Significant differences in cleaning efficacy were observed among the different tooth thirds within each experimental group, with the apical third exhibiting the highest presence of smear layer. Conclusion: Within the limitations of the study, irrigant activation demonstrated higher efficiency in smear layer removal from root canal systems compared to conventional irrigation techniques. iVac showed the best cleaning performance in each third, particularly in the apical third. Clinical relevance: iVac technology offers significant potential for improving clinical outcomes.