Accelerator/retarder admixtures are often added into concrete to improve its early-age strength, which needs to be effectively monitored during its hardening process. The electromechanical impedance (EMI) technique has validated its effectiveness for concrete hydration monitoring, this study attempted to extend the EMI technique to monitor 28-day age of strength gain in concrete that added with accelerator/retarder admixtures. Two types of new piezoelectric (PZT) transducers namely cement/aluminum embedded PZT (CEP/AEP) were proposed for EMI monitoring. The feasibility of the CEP and AEP was first verified via finite element analysis, where hydration heat effect on the two types of transducers was comparatively evaluated by numerical modeling. In the experiment, CEP/AEP transducers were applied to monitor the strength gain in concrete cubes, where characteristics of EMI signature and its statistical indices including root mean square deviation (RMSD) and mean absolute percentage deviation (MAPD) were analyzed and correlated to strength development in concrete. Monitoring results demonstrated that concrete hydration triggered by retarder/accelerator were successfully captured by EMI signature. RMSD and MAPD indices further indicated that AEP had preferable performance than CEP transducer for monitoring early-age strength gain of concrete, as it could immune from hydration heat effect.
Concrete structures in service are often subjected to environmental/operational temperature effects, which change their inherent properties and also inflict a challenge to their extrinsic monitoring systems. Recently, piezoelectric lead zirconate titanate (PZT)-based electromechanical admittance technique has been increasingly growing into an effective tool for concrete structural health monitoring; however, uncertainty in the changes of monitoring signals induced by temperature impact on concrete/PZT sensor would inevitably cause interference to structural damage detection, which adversely hinder its application from laboratory to engineering practice. This article, aiming at exploring the temperature effect on the electromechanical admittance–based concrete damage evaluation, primarily covered a series of theoretical/numerical analysis with rigorously experimental verifications. Three aspects of comparative studies were performed in theoretical/numerical analysis: (1) thermal-dependent parameters were inclusively evaluated in contribution to the electromechanical admittance characteristics via PZT-structure interaction models; (2) three-dimensional finite element analysis in multi-physics coupled field was employed to qualitatively assess the singular temperature effect on the electromechanical admittance behaviors of free-vibrated PZT, surface-bonded PZT/inside-embedded PZT coupled healthy concrete cubes; and (3) depending on the modeling of surface-bonded PZT-/inside-embedded PZT-cracked concrete cube, thermal effect on damage evaluation was addressed via quantification on the electromechanical admittance variations. In the experimental study, rigorous validation tests were carried out on a group of lab-scale concrete cubes, where surface-bonded PZT/inside-embedded PZT transducers were simultaneously employed for electromechanical admittance monitoring in view of thermal difference between concrete surface and its inner part. Correlation coefficient deviation value-based effective frequency shifts algorithm was also employed to compensate the temperature effect. Moreover, temperature effect was further testified on the monitoring of a full-scale shield-tunnel segment structure. Experimental results indicated that temperature triggered different behaviors of electromechanical admittance signatures for surface-bonded PZT/inside-embedded PZT transducers and contaminated the electromechanical admittance responses for damage detection. Structural damage severity level can be disadvantageously amplified by temperature increment even if under the same damage scenarios.
10 February 2022 in Journal of Intelligent Material Systems and Structures
This paper proposed an electromechanical admittance (EMA, inverse of impedance)-based concrete structural damage detection (SDD) approach using Principal Component Analysis (PCA) algorithm incorporated with neural network (NN). First, the PCA algorithm was applied to extract essential feature of the original EMA data obtained from an active piezoelectric lead zirconate titanate (PZT) transducer through data compression. Second, the extracted principle components were adopted as input of a generated NN model to enhance damage prediction ability of the EMA technique. Third, after a sufficient training of NN model using the PCA-processed data, structural damage in term of severity and location could be automatically predicted. Feasibility of the approach was evaluated via conducting an experiment on detecting crack damages in concrete cubic structure, performance of the NN model was analyzed using randomly varied different ratios of training dataset as well. Experimental results demonstrated that the proposed approach gives around 100% accuracy for crack identification, which provided an alternative paradigm of data-driven damage detection in concrete structures.
Considerable amount of electromechanical admittance data needs to be collected, transmitted and stored during in-situ and long-term structural health monitoring applications, and data loss could be inevitably met when processing the monitoring electromechanical admittance signals. In this article, an innovative compressed sensing–based approach is proposed to implement data recovery for electromechanical admittance technique–based concrete structural health monitoring. The basis of this approach is to first project the original conductance signature onto an observation vector as sampled data, and then transmit the observation vector with data loss to storage station, and finally recover the missing data via a compressed sensing process. For comparison, both convex optimization theory and orthogonal matching pursuit algorithm are introduced to accomplish the compressed sensing–based electromechanical admittance data loss recovery. Prior detection test of a concrete cube subjected to varied temperatures and practical monitoring experiment of full-scale concrete shield tunnel segment undergone bolt-loosened defects are utilized to validate the feasibility of the proposed approach. In lost electromechanical admittance data recovery process, two types of data loss, namely, single-consecutive-segment loss and multiple-consecutive-segment losses, in sampled data are taken into consideration for sufficiently interpreting the effectiveness and accuracy of the convex optimization and orthogonal matching pursuit approaches. In the temperature recognition and damage identification stage, amplitude and frequency shifts in resonance peaks, cooperated with a common statistical index called root-mean-squared-deviation, are harnessed to achieve the goal after the lossy conductance signatures are recovered. The results show that the orthogonal matching pursuit–based data recovery approach is superior to the convex optimization approach because of its smaller calculation of consumption as well as lower recovered errors.
Complete understanding of the adhesive curing effect of a bonded piezoelectric lead zirconate titanate (PZT) sensor on the electromechanical admittance (EMA, inverse of impedance) facilitates the accurate diagnosis of structural damages when employing the impedance technique for structural health monitoring. This article analytically and experimentally investigated the curing effect of adhesive layer on the EMA-based concrete structural damage detection. Curing effect was theoretically incorporated into shearing mechanism of adhesive layer to formulate a new one-dimensional PZT-structural impedance model. Analytical analysis of the curing effect on the EMA signature as well as the EMA-based damage diagnosis was calculably interpreted through the model. Proof-of-concept experiment was performed on testing a four-point bending reinforced concrete (RC) beam bonded with multiple PZT patches under adhesive curing. Experimental results demonstrated that singular shift in the EMA spectra under adhesive curing could be turned into three typical shifts when structural damage occurred, which cogently validated the analytical results. Quantifiable signal index further provided useful information for the identification of crack occurrence, progression, and reinforcement yielding of the RC beam. Results of this study potentially promoted the real-life engineering applications of impedance technique inclusive of deficient adhesive condition.