Hongping Zhu

Hongping Zhu

Auto-generated profile, based on publicly available information

Hongping Zhu

School of Civil and Hydraulic Engineering, Huazhong University of Science and Technology, Wuhan, Hubei, China

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

22 October 2016 in Sensors
Verified
Journal Article
Open access
PDF file
DWDansheng Wang
Dansheng Wang
QWQinghua Wang
Qinghua Wang
HWHao Wang
Hao Wang
HZHongping Zhu
Hongping Zhu
In the electromechanical impedance (EMI) method, the PZT patch performs the functions of both sensor and exciter. Due to the high frequency actuation and non-model based characteristics, the EMI method can be utilized to detect incipient structural damage. In recent years EMI techniques have been widely applied to monitor the health status of concrete and steel materials, however, studies on application to timber are limited. This paper will explore the feasibility of using the EMI technique for damage detection in timber specimens. In addition, the conventional damage index, namely root mean square deviation (RMSD) is employed to evaluate the level of damage. On that basis, a new damage index, Mahalanobis distance based on RMSD, is proposed to evaluate the damage severity of timber specimens. Experimental studies are implemented to detect notch and hole damage in the timber specimens. Experimental results verify the availability and robustness of the proposed damage index and its superiority over the RMSD indexes.

1 January 2019 in Journal of Engineering Mechanics
Verified
Journal Article
Closed access
Wenai ShenWenai Shen
Wenai Shen
Songye ZhuSongye Zhu
Songye Zhu
HZHongping Zhu
Hongping Zhu
With the extensive studies on energy harvesting via electromagnetic devices in civil or mechanical structures, a novel dual-function device, termed electromagnetic damping and energy harvesting (EMDEH) device, has been proposed in recent years, whose design represents a dual-objective optimization problem by considering both vibration control and energy harvesting performance. However, an argument on whether or not vibration control and energy harvesting is contradictory has arisen, based mainly on the intuition that the former tries to suppress vibration magnitude while the latter benefits from large vibration amplitude. This paper clarifies this question through a theoretical analysis of coupled structure–EMDEH systems under stochastic excitations. The closed-form solutions of the damping power, as well as the output power of the EMDEH device when attached to single-degree-of-freedom (SDOF) and multidegree-of-freedom (MDOF) structures, are given based on random vibration theory. A numerical analysis of a 20-story steel structure installed with EMDEH devices is conducted to validate the theoretical predictions. The consistency between vibration control and energy harvesting in randomly excited structures with EMDEH devices in the presence of inherent structural damping is demonstrated for the first time.

1 March 2018 in Journal of Bridge Engineering
Verified
Journal Article
Closed access
HCHongyou Cao
Hongyou Cao
Xudong QianXudong Qian
Xudong Qian
Yunlai ZhouYunlai Zhou
Yunlai Zhou
ZCZhijun Chen
Zhijun Chen
HZHongping Zhu
Hongping Zhu
This study investigates the structural characteristics of midtowers in three-tower suspension bridges and proposes a direct approach to determining feasible midtower stiffness for preliminary designs. The lateral stiffness analysis of bridges demonstrates the feasible midtower stiffness is located in a range that can be obtained using a simplified multispan suspension bridge model. This study also defines dimensionless midtower stiffness, and a parametric analysis is carried out in it to examine the effects of different parameters, including the sag-to-span ratio, side-to-main span ratio, dead-to-live load ratio, span length, and traffic load, on the range of dimensionless midtower stiffness. The results illustrate that the range of dimensionless midtower stiffness relies mainly on the dead-to-live load ratio and the sag-to-span ratio. The dimensionless stiffness chart derived from the study is generic and provides an estimate of the feasible midtower stiffness of three-tower suspension bridges with different design parameters.

24 May 2016 in Smart Materials and Structures
Verified
Journal Article
Closed access
PDF file
DWDansheng Wang
Dansheng Wang
ZLZhi Li
Zhi Li
HZHongping Zhu
Hongping Zhu
In the past twenty years, the electromechanical (EM) impedance technique has been investigated extensively in the mechanical, aviation and civil engineering fields. Many different EM impedance models have been proposed to characterize the interaction between the surface-bonded PZT transducer and the host structure. This paper formulates a new three-dimensional EM impedance model characterizing the interaction between an embedded circle dual-PZT transducer and the host structure based on the effective impedance concept. The proposed model is validated by experimental results from a group of smart cement cubes, in which three circle dual-PZT transducers are embedded respectively. In addition, a new EM impedance measuring method for the dual-PZT transducer is also introduced. In the measuring method, only a common signal generator and an oscilloscope are needed, by which the exciting and receiving voltage signals are obtained respectively. Combined with fast Fourier transform the EM impedance signatures of the dual-PZT transducers are obtained.

8 July 2018 in Sensors
Verified
Journal Article
Open access
PDF file
PZPin Zhou
Pin Zhou
DWDansheng Wang
Dansheng Wang
HZHongping Zhu
Hongping Zhu
This paper presents a novel structural damage detection indicator, i.e., fourth-order voltage statistical moment (FVSM) based on the electromechanical impedance (EMI) principle, and then proposes a two-step damage detection method based on the novel indicator and a differential evolution algorithm (DEA). In this study, several lead zirconate titanate (PZT) sensors bonded to an experimental steel beam were utilized to acquire the time-domain voltage responses. On this basis, the fourth-order voltage statistical moments (FVSMs) of the voltage responses are computed to locate the damage element in the detected structure, and the proposed damage detection method is utilized to quantify the damage. In addition, theoretical PZT voltage responses are also calculated based on the piezoelectric theory and the spectral element method (SEM). Experimental results verify the accuracy of the theoretical voltage values and the effectiveness of the proposed damage indicator. Results indicate that the FVSM is effective in locating the damage element. Integrated with DEA, the proposed technique is capable of quantifying damage.