Karim Elgammal

Dr. Karim Elgammal

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 October 2015 in Nanoscale
Verified
Journal Article
Open access
PDF file
ASAnderson D. Smith
Anderson D. Smith
KEKarim Elgammal
Karim Elgammal
FNFrank Niklaus
Frank Niklaus
ADAnna Delin
Anna Delin
AFAndreas C. Fischer
Andreas C. Fischer
MLMax Lemme
Max Lemme
We demonstrate resistive humidity sensing using a single-layer graphene patch placed on top of a SiO2 layer on a Si wafer.

21 April 2017 in RSC Advances
Verified
Journal Article
Open access
PDF file
ASAnderson David Smith
Anderson David Smith
KEKarim Elgammal
Karim Elgammal
XFXuge Fan
Xuge Fan
MLMax Lemme
Max Lemme
ADAnna Delin
Anna Delin
MÖMikael Östling
Mikael Östling
We present graphene-based CO2 sensing and analyze its cross-sensitivity with humidity.

1 February 2018 in Carbon
Verified
Journal Article
Closed access
XFXuge Fan
Xuge Fan
KEKarim Elgammal
Karim Elgammal
ASAnderson D. Smith
Anderson D. Smith
MÖMikael Östling
Mikael Östling
ADAnna Delin
Anna Delin
FNFrank Niklaus
Frank Niklaus

6 September 2019 in IEEE Transactions on Electron Devices
Verified
Journal Article
Closed access
KTKai Tian
Kai Tian
Anders HallénAnders Hallén
Anders Hallén
JQJinwei Qi
Jinwei Qi
MNMuhammad Nawaz
Muhammad Nawaz
SMShenhui Ma
Shenhui Ma
WLWeihua Liu
Weihua Liu

2 November 2018 in ACS Applied Materials & Interfaces
Verified
Journal Article
Open access
AQArne Quellmalz
Arne Quellmalz
ASAnderson D. Smith
Anderson D. Smith
KEKarim Elgammal
Karim Elgammal
XFXuge Fan
Xuge Fan
ADAnna Delin
Anna Delin
FNFrank Niklaus
Frank Niklaus
The electrical contact resistance at metal-graphene interfaces can significantly degrade the properties of graphene devices and is currently hindering the full exploitation of graphene’s potential. Therefore, the influence of environmental factors, such as humidity, on the metal-graphene contact resistance is of interest for all graphene devices that operate without hermetic packaging. We experimentally studied the influence of humidity on bottom-contacted chemical vapor deposited (CVD) graphene-gold contacts, by extracting the contact resistance from transmission line model (TLM) test structures. Our results indicate that the contact resistance is not significantly affected by changes in relative humidity (RH). This behavior is in contrast to the measured humidity sensitivity (0.059 ± 0.011 %/%RH ) of graphene’s sheet resistance. In addition, we employ density functional theory (DFT) simulations to support our experimental observations. Our DFT simulation results demonstrate that the electronic structure of the graphene sheet on top of silica is much more sensitive to adsorbed water molecules than the charge density at the interface between gold and graphene. Thus, we predict no degradation of device performance by alterations in contact resistance when such contacts are exposed to humidity. This knowledge underlines that bottom-contacting of graphene is a viable approach for a variety of graphene devices and the back end of the line integration on top of conventional integrated circuits.

24 December 2019 in Sensors
Verified
Journal Article
Open access
PDF file
MSMahmoud Sakr
Mahmoud Sakr
KEKarim Elgammal
Karim Elgammal
ADAnna Delin
Anna Delin
Mohamed SerryMohamed Serry
Mohamed Serry
Non-enzymatic glucose sensing is a crucial field of study because of the current market demand. This study proposes a novel design of glucose sensor with enhanced selectivity and sensitivity by using graphene Schottky diodes, which is composed of graphene (G)/platinum oxide (PtO)/n-silicon (Si) heterostructure. The sensor was tested with different glucose concentrations and interfering solutions to investigate its sensitivity and selectivity. Different structures of the device were studied by adjusting the platinum oxide film thickness to investigate its catalytic activity. It was found that the film thickness plays a significant role in the efficiency of glucose oxidation and hence in overall device sensitivity. 0.8–2 μA output current was obtained in the case of 4–10 mM with a sensitivity of 0.2 μA/mM.cm2. Besides, results have shown that 0.8 μA and 15 μA were obtained by testing 4 mM glucose on two different PtO thicknesses, 30 nm and 50 nm, respectively. The sensitivity of the device was enhanced by 150% (i.e., up to 30 μA/mM.cm2) by increasing the PtO layer thickness. This was attributed to both the increase of the number of active sites for glucose oxidation as well as the increase in the graphene layer thickness, which leads to enhanced charge carriers concentration and mobility. Moreover, theoretical investigations were conducted using the density function theory (DFT) to understand the detection method and the origins of selectivity better. The working principle of the sensors puts it in a competitive position with other non-enzymatic glucose sensors. DFT calculations provided a qualitative explanation of the charge distribution across the graphene sheet within a system of a platinum substrate with D-glucose molecules above. The proposed G/PtO/n-Si heterostructure has proven to satisfy these factors, which opens the door for further developments of more reliable non-enzymatic glucometers for continuous glucose monitoring systems.