Jian-Guo Zhang Zhang

Dr. Jian-Guo Zhang Zhang


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 April 2024 in Medical & Biological Engineering & Computing
Verified
Journal Article
Closed access
PDF file
PCPeng Chen
Peng Chen
JZJian-Guo Zhang Zhang
Jian-Guo Zhang Zhang
JYJuan Yao
Juan Yao
FHFengling Hu
Fengling Hu
LSLiang Song
Liang Song
YYYoucheng Yu
Youcheng Yu

17 November 2023 in Journal of Stomatology Oral and Maxillofacial Surgery
Verified
Journal Article
Closed access
PCPeng Chen
Peng Chen
JZJian-Guo Zhang Zhang
Jian-Guo Zhang Zhang
YJYichuan Jiang
Yichuan Jiang
YLYizhuo Li
Yizhuo Li
LSLiang Song
Liang Song
YYYoucheng Yu
Youcheng Yu

15 July 2020 in Metals
Verified
Journal Article
Open access
PDF file
YJYunqiang Jiang
Yunqiang Jiang
BWBinjun Wang
Binjun Wang
CXChun Xu
Chun Xu
JZJian-Guo Zhang Zhang
Jian-Guo Zhang Zhang
Using molecular dynamics (MD) simulation, the strain-induced phase transitions in pure body-centered-cubic (bcc) iron (Fe) thin films containing twin boundaries (TBs) with different TB fractions and orientations are studied. Two groups of bcc thin films with different TB-surface orientation relationships are designed. In film group 1, the (112) [ 11 1 ¯ ] TBs are perpendicular to the ( 11 1 ¯ ) free surfaces, while the (112) [ 11 1 ¯ ] TBs are parallel to the free surfaces in film group 2. We vary the TB numbers inserted into the films to study the effect of TB fraction on the phase transition. Biaxial strains are applied to the films to induce the bcc to close packed (cp) phase transition. The critical strain, at which the first phase transition takes place, decreases with the TB fraction increase in film group 1 with a perpendicular TB-surface orientation, while such a relationship is not observed in film group 2 with parallel TB-surface orientation. We focus on the free surface and TB as the nucleation positions of the new phase and the afterward growth. In addition, the dynamics of the phase transition is discussed. This work may help to understand the mechanism of phase transition in nanoscale or surface-dominant systems with pre-existing defects.

1 January 2020 in Journal of Applied Optics
Verified
Journal Article
Closed access
PDF file
JZJian-Guo Zhang Zhang
Jian-Guo Zhang Zhang
LYLi Ying
Li Ying
QJQi Jiakun
Qi Jiakun
JTJi Tiantian
Ji Tiantian
LJLiu Jun
Liu Jun
Aiming at the problem of irregular shape and low contrast of the scratches in the image of mobile phone screen, a method based on machine vision was proposed to detect the surface scratches of mobile phone screen. Firstly, the PatMax algorithm and affine transformation were adopted to preprocess the screen images of mobile phone. Then the shear transformation was used to decompose the image into two parts: low frequency and high frequency, the element shapes in four directions of 0°, 45°, 90° and 135° were constructed to perform gray-scale closing operation on the low frequency part, and the N × M median filter denoising operation was performed on the high frequency part, the enhanced image was generated by the inverse shear transformation. Finally, the improved Otsu double threshold method was used to extract the target. 450 pieces of mobile phone screen images were randomly selected for experiments, and the highest detection rate is 98.7%. The results show that this method can effectively enhance the detail information of the images, which greatly guarantees the integrity of the scratch defects.

1 January 2025 in AIMS Bioengineering
Verified
Journal Article
Open access
PDF file
SHSong Huang
Song Huang
JZJian-Guo Zhang Zhang
Jian-Guo Zhang Zhang
XZXiaoying Zhang
Xiaoying Zhang
FHFengling Hu
Fengling Hu
YYYoucheng Yu
Youcheng Yu
This study evaluated the feasibility of cantilever and fixed bridge restorations through finite element analysis of narrow-diameter implants (NDls) in a 4-unit anterior mandibular bridge. A total of five restoration models were analyzed using static, modal, and dynamic analyses. Results showed that the fixed bridge supported by three NDIs exhibited the lowest stress (crown: 27.429 MPa, implant: 58.608 MPa) and optimal stability (resonance frequency: 8653 Hz). The maximum stresses in cantilever bridge implants (crowns: 78.803 MPa, implants: 146.27) were 2–3 times higher than those in fixed bridges. Dynamic loading generated the highest stresses during the second phase of the masticatory cycle, with overall stress 10%–30% higher than under static loading. Fixed bridges supported by three NDIs are recommended for optimal stress distribution, while cantilever bridges should be used with caution.

19 January 2026 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
BSBenhao Sun
Benhao Sun
JZJian-Guo Zhang Zhang
Jian-Guo Zhang Zhang
PCPeng Chen
Peng Chen
HHHu Hou
Hu Hou
SHSong Huang
Song Huang
FHFengling Hu
Fengling Hu
The purpose of this study was to use finite element analysis (FEA) to evaluate the mechanical effects of eight different anti-rotation structures in fin-ty