Fengling Hu

Fengling Hu


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 April 2024 in Medical & Biological Engineering & Computing
Verified
Journal Article
Closed access
PDF file
PCPeng Chen
Peng Chen
JZJian-Guo Zhang Zhang
Jian-Guo Zhang Zhang
JYJuan Yao
Juan Yao
FHFengling Hu
Fengling Hu
LSLiang Song
Liang Song
YYYoucheng Yu
Youcheng Yu

17 November 2023 in Journal of Stomatology Oral and Maxillofacial Surgery
Verified
Journal Article
Closed access
PCPeng Chen
Peng Chen
JZJian-Guo Zhang Zhang
Jian-Guo Zhang Zhang
YJYichuan Jiang
Yichuan Jiang
YLYizhuo Li
Yizhuo Li
LSLiang Song
Liang Song
YYYoucheng Yu
Youcheng Yu

29 May 2025 in Signal, Image and Video Processing
Verified
Journal Article
Closed access
PDF file
JZJianguo Zhang
Jianguo Zhang
MLMeng Lin
Meng Lin
HHHu Hou
Hu Hou
BSBenhao Sun
Benhao Sun
FHFengling Hu
Fengling Hu
MLMenghan Li
Menghan Li

1 January 2025 in AIMS Bioengineering
Verified
Journal Article
Open access
PDF file
SHSong Huang
Song Huang
JZJian-Guo Zhang Zhang
Jian-Guo Zhang Zhang
XZXiaoying Zhang
Xiaoying Zhang
FHFengling Hu
Fengling Hu
YYYoucheng Yu
Youcheng Yu
This study evaluated the feasibility of cantilever and fixed bridge restorations through finite element analysis of narrow-diameter implants (NDls) in a 4-unit anterior mandibular bridge. A total of five restoration models were analyzed using static, modal, and dynamic analyses. Results showed that the fixed bridge supported by three NDIs exhibited the lowest stress (crown: 27.429 MPa, implant: 58.608 MPa) and optimal stability (resonance frequency: 8653 Hz). The maximum stresses in cantilever bridge implants (crowns: 78.803 MPa, implants: 146.27) were 2–3 times higher than those in fixed bridges. Dynamic loading generated the highest stresses during the second phase of the masticatory cycle, with overall stress 10%–30% higher than under static loading. Fixed bridges supported by three NDIs are recommended for optimal stress distribution, while cantilever bridges should be used with caution.

28 October 2025 in Journal of Materials Engineering and Performance
Verified
Journal Article
Closed access
PDF file
JZJianguo Zhang
Jianguo Zhang
YLYehui Li
Yehui Li
GWGuan Wang
Guan Wang
XZXiaoying Zhang
Xiaoying Zhang
FHFengling Hu
Fengling Hu

19 January 2026 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
BSBenhao Sun
Benhao Sun
JZJian-Guo Zhang Zhang
Jian-Guo Zhang Zhang
PCPeng Chen
Peng Chen
HHHu Hou
Hu Hou
SHSong Huang
Song Huang
FHFengling Hu
Fengling Hu
The purpose of this study was to use finite element analysis (FEA) to evaluate the mechanical effects of eight different anti-rotation structures in fin-ty