Commercial hemodialyzers are hollow-fiber cylindrical modules with dimensions and inlet–outlet configurations dictated mostly by practice. However, alternative configurations are possible, and one may ask how they would behave in terms of performance. In principle, it would be possible to depart from the standard counter-flow design, while still keeping high clearance values, thanks to the increase in the shell-side Sherwood number (Sh) due to the cross-flow. To elucidate these aspects, a previously developed computational model was used in which blood and dialysate are treated as flowing through two interpenetrating porous media. Measured Darcy permeabilities and mass transfer coefficients derived from theoretical arguments and CFD simulations conducted at unit-cell scale were used. Blood and dialysate were alternately simulated via an iterative strategy, while appropriate source terms accounted for water and solute exchanges. Several module configurations sharing the same membrane area, but differing in overall geometry and inlet–outlet arrangement, were simulated, including a commercial unit. Although the shell-side Sherwood number increased in almost all the alternative configurations (from 14 to 25 in the best case), none of them outperformed in terms of clearance the commercial one, approaching the latter (257 vs. 255 mL/min) only in the best case. These findings confirmed the effectiveness of the established commercial module design for the currently available membrane properties.
The results of an experimental investigation on pressure drop and heat transfer in spacer-filled plane channels, which are representative of Membrane Distillation units, are presented and discussed. Local and mean heat transfer coefficients were obtained by using Thermochromic Liquid Crystals and Digital Image Processing. The performances of a novel spacer geometry, consisting of spheres that are connected by cylindrical rods, and are hereafter named spheres spacers, were compared with those of more conventional woven and overlapped spacers at equal values of the Reynolds number Re (in the range ~150 to ~2500), the pitch-to-channel height ratio, the flow attack angle and the thermal boundary conditions (two-side heat transfer). For any flow rate, the novel spacer geometry provided the least friction coefficient and a mean Nusselt number intermediate between those of the overlapped and the woven spacers. For any pressure drop and for any pumping power, the novel spacer provided the highest mean Nusselt number over the whole Reynolds number range that was investigated. The influence of buoyancy was also assessed for the case of the horizontal channels. Under the experimental conditions (channel height H ≈ 1 cm, ΔT ≈ 10 °C), it was found to be large in empty (spacer-less) channels that were up to Re ≈ 1200 (corresponding to a Richardson number Ri of ~0.1), but it was much smaller and limited to the range Re < ~500 (Ri < ~0.5) in the spacer-filled channels.
8 January 2023 in International Journal of Heat and Mass Transfer
The present review summarizes a vast body of literature on the subject of Membrane Distillation (MD), with a special emphasis on the existing results and correlations for the transmembrane transport of heat and mass. The issue of saltwater physical properties is also discussed in depth, whereas the advective transport of heat and salt concentration in the feed and permeate compartments is only briefly mentioned but is beyond the scope of this review. The paper does not aim to provide a complete treatment of the subject of MD, which can be found in other publications. Rather, it suggests the data and correlations most suitable for the range of operating conditions typically expected in actual units implementing Direct Contact Membrane Distillation (DCMD), including hollow fiber designs, with a view to assist model development. The focus is on MD for water desalination, although some results may apply well to other fields.