Gaspare Marotta

Dr. Gaspare Marotta

Medtronic
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2016 in The Journal of Supercritical Fluids
Verified
Journal Article
Closed access
GCGiuseppe Caputo
Giuseppe Caputo
MDMartina Dispenza
Martina Dispenza
PRPatricia Rubio
Patricia Rubio
Francesca ScargialiFrancesca Scargiali
Francesca Scargiali
GMGaspare Marotta
Gaspare Marotta
ABAlberto Brucato
Alberto Brucato

1 January 2016 in The Journal of Supercritical Fluids
Verified
Journal Article
Closed access
GCGiuseppe Caputo
Giuseppe Caputo
PRPatricia Rubio
Patricia Rubio
Francesca ScargialiFrancesca Scargiali
Francesca Scargiali
GMGaspare Marotta
Gaspare Marotta
ABAlberto Brucato
Alberto Brucato

20 January 2022 in Membranes
Verified
Journal Article
Open access
PDF file
NCNunzio Cancilla
Nunzio Cancilla
Luigi GurreriLuigi Gurreri
Luigi Gurreri
GMGaspare Marotta
Gaspare Marotta
MCMichele Ciofalo
Michele Ciofalo
Andrea CipollinaAndrea Cipollina
Andrea Cipollina
Giorgio MicaleGiorgio Micale
Giorgio Micale
Commercial hemodialyzers are hollow-fiber cylindrical modules with dimensions and inlet–outlet configurations dictated mostly by practice. However, alternative configurations are possible, and one may ask how they would behave in terms of performance. In principle, it would be possible to depart from the standard counter-flow design, while still keeping high clearance values, thanks to the increase in the shell-side Sherwood number (Sh) due to the cross-flow. To elucidate these aspects, a previously developed computational model was used in which blood and dialysate are treated as flowing through two interpenetrating porous media. Measured Darcy permeabilities and mass transfer coefficients derived from theoretical arguments and CFD simulations conducted at unit-cell scale were used. Blood and dialysate were alternately simulated via an iterative strategy, while appropriate source terms accounted for water and solute exchanges. Several module configurations sharing the same membrane area, but differing in overall geometry and inlet–outlet arrangement, were simulated, including a commercial unit. Although the shell-side Sherwood number increased in almost all the alternative configurations (from 14 to 25 in the best case), none of them outperformed in terms of clearance the commercial one, approaching the latter (257 vs. 255 mL/min) only in the best case. These findings confirmed the effectiveness of the established commercial module design for the currently available membrane properties.

13 March 2017 in The Canadian Journal of Chemical Engineering
Verified
Journal Article
Closed access
PDF file
GMGaspare Marotta
Gaspare Marotta
JPJeremy Pruvost
Jeremy Pruvost
Francesca ScargialiFrancesca Scargiali
Francesca Scargiali
GCGiuseppe Caputo
Giuseppe Caputo
ABAlberto Brucato
Alberto Brucato

10 April 2014 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
MCM Ciofalo
M Ciofalo
MLM Di Liberto
M Di Liberto
GMGaspare Marotta
Gaspare Marotta

Verified
Closed access
GMGaspare Marotta
Gaspare Marotta
Francesca ScargialiFrancesca Scargiali
Francesca Scargiali
Serena LimaSerena Lima
Serena Lima
GCGiuseppe Caputo
Giuseppe Caputo
FGFranco Grisafi
Franco Grisafi
ABA. Brucato
A. Brucato