Zhiyi Zhang

Dr. Zhiyi Zhang


Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 November 2011 in Biomicrofluidics
Verified
Journal Article
Closed access
PDF file
ZZZhiyi Zhang
Zhiyi Zhang
PZPing Zhao
Ping Zhao
GXGaozhi Xiao
Gaozhi Xiao
BWBenjamin R. Watts
Benjamin R. Watts
CXChangqing Xu
Changqing Xu
A simple method of irreversibly sealing SU-8 microfluidic channels using PDMS is reported in this paper. The method is based on inducing a chemical reaction between PDMS and SU-8 by first generating amino groups on PDMS surface using N2 plasma treatment, then allowing the amino groups to react with the residual epoxy groups on SU-8 surface at an elevated temperature. The N2 plasma treatment of PDMS can be conducted using an ordinary plasma chamber and high purity N2, while the residual epoxy groups on SU-8 surface can be preserved by post-exposure baking SU-8 at a temperature no higher than 95 °C. The resultant chemical bonding between PDMS and SU-8 using the method create an interface that can withstand a stress that is greater than the bulk strength of PDMS. The bond is permanent and is long-term resistant to water. The method was applied in fabricating SU-8 microfluidi-photonic integrated devices, and the obtained devices were tested to show desirable performance.

7 May 2010 in Biomicrofluidics
Verified
Journal Article
Closed access
PDF file
YDYan Du
Yan Du
ZZZhiyi Zhang
Zhiyi Zhang
CYChaeHo Yim
ChaeHo Yim
MLMin Lin
Min Lin
Xudong CaoXudong Cao
Xudong Cao
We demonstrated a simple method for the device design of a staggered herringbone micromixer (SHM) using numerical simulation. By correlating the simulated concentrations with channel length, we obtained a series of concentration versus channel length profiles, and used mixing completion length Lm as the only parameter to evaluate the performance of device structure on mixing. Fluorescence quenching experiments were subsequently conducted to verify the optimized SHM structure for a specific application. Good agreement was found between the optimization and the experimental data. Since Lm is straightforward, easily defined and calculated parameter for characterization of mixing performance, this method for designing micromixers is simple and effective for practical applications.

1 March 2008 in Biomicrofluidics
Verified
Journal Article
Closed access
PDF file
ZZZhiyi Zhang
Zhiyi Zhang
PZPing Zhao
Ping Zhao
GXGaozhi Xiao
Gaozhi Xiao
MLMin Lin
Min Lin
Xudong CaoXudong Cao
Xudong Cao
A focusing-based microfluidic mixer was studied. The micromixer utilizes the focusing process required for cytometry to reduce the diffusion distance of molecules to be mixed in order to facilitate the passive diffusion-controlled mixing process. It was found that both the high flow rate ratio of the sheath flow to the flows to be mixed and the low flow rate of the mixing fluids resulted in the short mixing length required within the microfluidic channel. It was shown that a complete mixing was achieved within a distance of 4 mm in the micromixer for the focused mixing fluids at a flow rate of 2 μl/min and a flow rate ratio of the sheath flow to the flows to be mixed at 4:1. The mixer described here is simple and can be easily fabricated and controlled.

15 April 2016 in Micromachines
Verified
Journal Article
Open access
PDF file
YZYushan Zhang
Yushan Zhang
BWBenjamin R. Watts
Benjamin R. Watts
TGTianyi Guo
Tianyi Guo
ZZZhiyi Zhang
Zhiyi Zhang
CXChang-Qing Xu
Chang-Qing Xu
Qiyin FangQiyin Fang
Qiyin Fang
Optofluidic devices combining micro-optical and microfluidic components bring a host of new advantages to conventional microfluidic devices. Aspects, such as optical beam shaping, can be integrated on-chip and provide high-sensitivity and built-in optical alignment. Optofluidic microflow cytometers have been demonstrated in applications, such as point-of-care diagnostics, cellular immunophenotyping, rare cell analysis, genomics and analytical chemistry. Flow control, light guiding and collecting, data collection and data analysis are the four main techniques attributed to the performance of the optofluidic microflow cytometer. Each of the four areas is discussed in detail to show the basic principles and recent developments. 3D microfabrication techniques are discussed in their use to make these novel microfluidic devices, and the integration of the whole system takes advantage of the miniaturization of each sub-system. The combination of these different techniques is a spur to the development of microflow cytometers, and results show the performance of many types of microflow cytometers developed recently.

17 May 2010 in Micromachines
Verified
Journal Article
Open access
PDF file
YDYan Du
Yan Du
ZZZhiyi Zhang
Zhiyi Zhang
CYChaeHo Yim
ChaeHo Yim
MLMin Lin
Min Lin
Xudong CaoXudong Cao
Xudong Cao
We evaluated the dynamic micromixing performances in slanted groove micromixers (SGM) and staggered herringbone micromixers (SHM) and quantitatively compared their differences using concentration vs. channel length profiles obtained from numerical stimulations. It is found that faster and finer mixing took place in the SHM and the chaotic mixing was more effective at locations closer to the grooves; in comparison, slower and coarser mixing occurred throughout the whole channel of the SGM. Subsequently, the concentration profile-based characterization method was demonstrated in hybrid floor-grooved micromixers to study the interaction of SGM and SHM.

6 November 2012 in Langmuir
Verified
Journal Article
Closed access
PYPo Ying Yeh
Po Ying Yeh
ZZZhiyi Zhang
Zhiyi Zhang
MLMin Lin
Min Lin
Xudong CaoXudong Cao
Xudong Cao