Chang-Qing Xu

Dr. Chang-Qing Xu

orcid

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2004 in Optics Letters
Verified
Journal Article
Closed access
PDF file
CXChang-Qing Xu
Chang-Qing Xu
BCBo Chen
Bo Chen
A novel wavelength conversion scheme based on cascaded sum-frequency generation (SFG) and difference-frequency generation (DFG) is proposed and demonstrated in a MgO-doped LiNbO3 quasi-phase-matched waveguide. In this scheme, two pump wavelengths are set outside the communication band. It is shown that the same conversion efficiency can be achieved by use of two pump sources with lower output power (P1, P2) in this scheme compared with the conventional cascaded wavelength conversion technique based on second-harmonic generation and DFG with a single higher-power pump beam (P=P1+P2) that is due to the use of a larger SFG nonlinear coefficient. The results significantly influence the selection of a suitable nonlinear interaction scheme for practical applications.

15 April 2016 in Micromachines
Verified
Journal Article
Open access
PDF file
YZYushan Zhang
Yushan Zhang
BWBenjamin R. Watts
Benjamin R. Watts
TGTianyi Guo
Tianyi Guo
ZZZhiyi Zhang
Zhiyi Zhang
CXChang-Qing Xu
Chang-Qing Xu
Qiyin FangQiyin Fang
Qiyin Fang
Optofluidic devices combining micro-optical and microfluidic components bring a host of new advantages to conventional microfluidic devices. Aspects, such as optical beam shaping, can be integrated on-chip and provide high-sensitivity and built-in optical alignment. Optofluidic microflow cytometers have been demonstrated in applications, such as point-of-care diagnostics, cellular immunophenotyping, rare cell analysis, genomics and analytical chemistry. Flow control, light guiding and collecting, data collection and data analysis are the four main techniques attributed to the performance of the optofluidic microflow cytometer. Each of the four areas is discussed in detail to show the basic principles and recent developments. 3D microfabrication techniques are discussed in their use to make these novel microfluidic devices, and the integration of the whole system takes advantage of the miniaturization of each sub-system. The combination of these different techniques is a spur to the development of microflow cytometers, and results show the performance of many types of microflow cytometers developed recently.

13 December 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
YZYushan Zhang
Yushan Zhang
CXChang-Qing Xu
Chang-Qing Xu
TGTianyi Guo
Tianyi Guo
LHLingcheng Hong
Lingcheng Hong
One of the biggest challenges in rapid low concentration bacterial detection is the pre-concentration or pre-enrichment, which aims to increase bacteria concentration and reduce sample volume for easy bacterial detection. In practical bacterial detection, large-volume water samples with a pathogenic bacterial concentration of less than 1 CFU/mL have to be tested rapidly. The reported biosensors either have insufficient detection limit or have limited capability of handling a sufficiently large water sample. Therefore, a high-performance automated pre-enrichment process is strongly demanded in rapid practical bacterial detection. In this paper, a practical high performance automated bacterial concentration and recovery system (ABCRS) based on the combination of a ceramic membrane and tangential flow filtration technique was presented with short processing time (less than one hour), low pre-enrichment limit (≤0.005 CFU/mL), high concentration ratio (≥ 500), high recovery efficiency (~ 90%), and small final retentate volume (≤ 5 mL).

10 October 2012 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
BWBenjamin R. Watts
Benjamin R. Watts
ZZZhiyi Zhang
Zhiyi Zhang
CXChang-Qing Xu
Chang-Qing Xu
XCXudong Cao
Xudong Cao
MLMin Lin
Min Lin
An optofluidic device is demonstrated with photonic components integrated onto the chip for use in fluorescence and scatter detection and counting applications. The device is fabricated by integrating the optical and fluidic components in a single functional layer. Optical excitation on-chip is accomplished via a waveguide integrated with a system of lenses that reforms the geometry of the beam in the microfluidic channel into a specific shape that is more suitable for reliable detection. Separate counting tests by detecting fluorescence and scattered signals from 2.5 and 6.0 μm beads were performed and found to show detection reliability comparable to that of conventional means of excitation and an improvement over other microchip-based designs.

14 September 2010 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
BWBenjamin R. Watts
Benjamin R. Watts
TKThomas Kowpak
Thomas Kowpak
ZZZhiyi Zhang
Zhiyi Zhang
CXChang-Qing Xu
Chang-Qing Xu
SZShiping Zhu
Shiping Zhu
An optimal excitation beam shape is necessary to perform reliable flow cytometric analysis but has so far not been implemented in a photonic-microfluidic integrated (i.e. optofluidic) device. We have achieved this feature by integrating a 1D lens system with planar waveguides and microfluidic channel on a substrate using one patterning material via a one-shot process. In this paper, we report the method of design and the performance of specifically formed excitation regions shaped to be ideal for reducing double detections, improving SNR, and for reliable detection in a flow cytometry application. Demonstration of different sizes via changes to lens design shows the ability to control the width of the shaped beam according to a targeted detection.

7 September 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
AEAndres Escobar
Andres Escobar
PCPhylis Chiu
Phylis Chiu
Jianxi QuJianxi Qu
Jianxi Qu
YZYushan Zhang
Yushan Zhang
CXChang-Qing Xu
Chang-Qing Xu
The rapid detection and quantification of infectious pathogens is an essential component to the control of potentially lethal outbreaks among human populations worldwide. Several of these highly infectious pathogens, such as Middle East respiratory syndrome (MERS) and severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), have been cemented in human history as causing epidemics or pandemics due to their lethality and contagiousness. SARS-CoV-2 is an example of these highly infectious pathogens that have recently become one of the leading causes of globally reported deaths, creating one of the worst economic downturns and health crises in the last century. As a result, the necessity for highly accurate and increasingly rapid on-site diagnostic platforms for highly infectious pathogens, such as SARS-CoV-2, has grown dramatically over the last two years. Current conventional non-microfluidic diagnostic techniques have limitations in their effectiveness as on-site devices due to their large turnaround times, operational costs and the need for laboratory equipment. In this review, we first present criteria, both novel and previously determined, as a foundation for the development of effective and viable on-site microfluidic diagnostic platforms for several notable pathogens, including SARS-CoV-2. This list of criteria includes standards that were set out by the WHO, as well as our own “seven pillars” for effective microfluidic integration. We then evaluate the use of microfluidic integration to improve upon currently, and previously, existing platforms for the detection of infectious pathogens. Finally, we discuss a stage-wise means to translate our findings into a fundamental framework towards the development of more effective on-site SARS-CoV-2 microfluidic-integrated platforms that may facilitate future pandemic diagnostic and research endeavors. Through microfluidic integration, many limitations in currently existing infectious pathogen diagnostic platforms can be eliminated or improved upon.