ESExperts' Working Group on Reporting Standards for MR Spectroscopy
Experts' Working Group on Reporting Standards for MR Spectroscopy
+16
The translation of MRS to clinical practice has been impeded by the lack of technical standardization. There are multiple methods of acquisition, post‐processing, and analysis whose details greatly impact the interpretation of the results. These details are often not fully reported, making it difficult to assess MRS studies on a standardized basis. This hampers the reviewing of manuscripts, limits the reproducibility of study results, and complicates meta‐analysis of the literature. In this paper a consensus group of MRS experts provides minimum guidelines for the reporting of MRS methods and results, including the standardized description of MRS hardware, data acquisition, analysis, and quality assessment. This consensus statement describes each of these requirements in detail and includes a checklist to assist authors and journal reviewers and to provide a practical way for journal editors to ensure that MRS studies are reported in full.
Standardization of b values allows improved interstudy comparisons on the diagnostic accuracy of diffusion-weighted MR breast examinations. PurposeTo compare the diagnostic quality of diffusion-weighted (DW) imaging schemes with regard to apparent diffusion coefficient (ADC) accuracy, ADC precision, and DW imaging contrast-to-noise ratio (CNR) for different types of lesions and breast tissue. Materials and MethodsInstitutional review board approval and written, informed consent were obtained. Fifty-one patients with histopathologic correlation or follow-up performed with a 3.0-T MR imager were included in this study. There were 112 regions of interest drawn in 24 malignant, 17 benign, 20 cystic, and 51 normal tissue regions. ADC maps were calculated for combinations of 10 b values (range, 0–1250 sec/mm2). Differences in ADC among tissue types were evaluated. The CNRs of lesions at DW imaging were compared for all b values. A repeated-measures analysis of variance was used to assess lesion differentiation. ResultsADCs calculated from b values of 50 and 850 sec/mm2 were 0.99 × 10−3 mm2/sec ± 0.18 (standard deviation), 1.47 × 10−3 mm2/sec ± 0.21...
We found significantly higher image quality and lesion conspicuity of breast diffusion-weighted imaging based on readout-segmented echo-planar imaging compared with standard single-shot echo-planar imaging, with improved diagnostic accuracy from 90% to 96% with a clinical high-field-strength (3.0-T) MR imager. PurposeTo qualitatively and quantitatively compare the diagnostic value of diffusion-weighted (DW) magnetic resonance (MR) imaging based on standard single-shot echo-planar imaging and readout-segmented echo-planar imaging in patients with breast cancer at 3.0 T.Materials and MethodsInstitutional review board approval and written informed consent were obtained. Forty-seven patients with 49 histopathologically verified lesions were included in this study. In all patients, DW imaging, with single-shot echo-planar imaging and readout-segmented echo-planar imaging with comparable imaging parameters, was performed with a 3.0-T MR imager. Two independent readers visually assessed image quality and lesion conspicuity, and image properties (ie, signal-to-noise ratio, contrast, geometric distortions) were quantified. Regions of interest were drawn in all lesions (28 malignant, 21 benign) and in the normal breast parenchyma to investigate differences in apparent diffusion coefficient (ADC). Diagnostic accuracy was ...
The growing interest in ultra-high field MRI, with more than 35.000 MR examinations already performed at 7T, is related to improved clinical results with regard to morphological as well as functional and metabolic capabilities. Since the signal-to-noise ratio increases with the field strength of the MR scanner, the most evident application at 7T is to gain higher spatial resolution in the brain compared to 3T. Of specific clinical interest for neuro applications is the cerebral cortex at 7T, for the detection of changes in cortical structure, like the visualization of cortical microinfarcts and cortical plaques in Multiple Sclerosis. In imaging of the hippocampus, even subfields of the internal hippocampal anatomy and pathology may be visualized with excellent spatial resolution. Using Susceptibility Weighted Imaging, the plaque-vessel relationship and iron accumulations in Multiple Sclerosis can be visualized, which may provide a prognostic factor of disease. Vascular imaging is a highly promising field for 7T which is dealt with in a separate dedicated article in this special issue. The static and dynamic blood oxygenation level-dependent contrast also increases with the field strength, which significantly improves the accuracy of pre-surgical evaluation of vital brain areas before tumor removal. Improvement in acquisition and hardware technology have also resulted in an increasing number of MR spectroscopic imaging studies in patients at 7T. More recent parallel imaging and short-TR acquisition approaches have overcome the limitations of scan time and spatial resolution, thereby allowing imaging matrix sizes of up to 128×128. The benefits of these acquisition approaches for investigation of brain tumors and Multiple Sclerosis have been shown recently. Together, these possibilities demonstrate the feasibility and advantages of conducting routine diagnostic imaging and clinical research at 7T.
Over more than 30 years in vivo MR spectroscopic imaging (MRSI) has undergone an enormous evolution from theoretical concepts in the early 1980s to the robust imaging technique that it is today. The development of both fast and efficient sampling and reconstruction techniques has played a fundamental role in this process. State‐of‐the‐art MRSI has grown from a slow purely phase‐encoded acquisition technique to a method that today combines the benefits of different acceleration techniques. These include shortening of repetition times, spatial‐spectral encoding, undersampling of k‐space and time domain, and use of spatial‐spectral prior knowledge in the reconstruction. In this way in vivo MRSI has considerably advanced in terms of spatial coverage, spatial resolution, acquisition speed, artifact suppression, number of detectable metabolites and quantification precision. Acceleration not only has been the enabling factor in high‐resolution whole‐brain 1H‐MRSI, but today is also common in non‐proton MRSI (31P, 2H and 13C) and applied in many different organs. In this process, MRSI techniques had to constantly adapt, but have also benefitted from the significant increase of magnetic field strength boosting the signal‐to‐noise ratio along with high gradient fidelity and high‐density receive arrays. In combination with recent trends in image reconstruction and much improved computation power, these advances led to a number of novel developments with respect to MRSI acceleration. Today MRSI allows for non‐invasive and non‐ionizing mapping of the spatial distribution of various metabolites’ tissue concentrations in animals or humans, is applied for clinical diagnostics and has been established as an important tool for neuro‐scientific and metabolism research. This review highlights the developments of the last five years and puts them into the context of earlier MRSI acceleration techniques. In addition to 1H‐MRSI it also includes other relevant nuclei and is not limited to certain body regions or specific applications.