Gilbert Hangel

Dr. Gilbert Hangel

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2018 in NeuroImage
Verified
Journal Article
Open access
Siegfried TrattnigSiegfried Trattnig
Siegfried Trattnig
ESElisabeth Springer
Elisabeth Springer
Wolfgang BognerWolfgang Bogner
Wolfgang Bogner
GHGilbert Hangel
Gilbert Hangel
BSBernhard Strasser
Bernhard Strasser
SRSimon Daniel Robinson
Simon Daniel Robinson
The growing interest in ultra-high field MRI, with more than 35.000 MR examinations already performed at 7T, is related to improved clinical results with regard to morphological as well as functional and metabolic capabilities. Since the signal-to-noise ratio increases with the field strength of the MR scanner, the most evident application at 7T is to gain higher spatial resolution in the brain compared to 3T. Of specific clinical interest for neuro applications is the cerebral cortex at 7T, for the detection of changes in cortical structure, like the visualization of cortical microinfarcts and cortical plaques in Multiple Sclerosis. In imaging of the hippocampus, even subfields of the internal hippocampal anatomy and pathology may be visualized with excellent spatial resolution. Using Susceptibility Weighted Imaging, the plaque-vessel relationship and iron accumulations in Multiple Sclerosis can be visualized, which may provide a prognostic factor of disease. Vascular imaging is a highly promising field for 7T which is dealt with in a separate dedicated article in this special issue. The static and dynamic blood oxygenation level-dependent contrast also increases with the field strength, which significantly improves the accuracy of pre-surgical evaluation of vital brain areas before tumor removal. Improvement in acquisition and hardware technology have also resulted in an increasing number of MR spectroscopic imaging studies in patients at 7T. More recent parallel imaging and short-TR acquisition approaches have overcome the limitations of scan time and spatial resolution, thereby allowing imaging matrix sizes of up to 128×128. The benefits of these acquisition approaches for investigation of brain tumors and Multiple Sclerosis have been shown recently. Together, these possibilities demonstrate the feasibility and advantages of conducting routine diagnostic imaging and clinical research at 7T.

1 March 2018 in NeuroImage
Verified
Journal Article
Open access
GHGilbert Hangel
Gilbert Hangel
BSBernhard Strasser
Bernhard Strasser
MPMichal Považan
Michal Považan
EHEva Heckova
Eva Heckova
LHLukas Hingerl
Lukas Hingerl
Wolfgang BognerWolfgang Bogner
Wolfgang Bogner
MRSI in the brain at ≥7 T is a technique of great promise, but has been limited mainly by low B0/B1+-homogeneity, specific absorption rate restrictions, long measurement times, and low spatial resolution. To overcome these limitations, we propose an ultra-high resolution (UHR) MRSI sequence that provides a 128×128 matrix with a nominal voxel volume of 1.7×1.7×8mm3 in a comparatively short measurement time. A clinically feasible scan time of 10-20min is reached via a short TR of 200 ms due to an optimised free induction decay-based acquisition with shortened water suppression as well as parallel imaging (PI) using Controlled Aliasing In Parallel Imaging Results IN Higher Acceleration (CAIPIRINHA). This approach is not limited to a rectangular region of interest in the centre of the brain, but also covers cortical brain regions. Transversal pulse-cascaded Hadamard encoding was able to further extend the coverage to 3D-UHR-MRSI of four slices (100×100×4 matrix size), with a measurement time of 17min. Lipid contamination was removed during post-processing using L2-regularisation. Simulations, phantom and volunteer measurements were performed. The obtained single-slice and 3D-metabolite maps show the brain in unprecedented detail (e.g., hemispheres, ventricles, gyri, and the contrast between grey and white matter). This facilitates the use of UHR-MRSI for clinical applications, such as measurements of the small structures and metabolic pathologic deviations found in small Multiple Sclerosis lesions.

19 December 2019 in Investigative Radiology
Verified
Journal Article
Closed access
LHLukas Hingerl
Lukas Hingerl
BSBernhard Strasser
Bernhard Strasser
PMPhilipp Moser
Philipp Moser
GHGilbert Hangel
Gilbert Hangel
SMStanislav Motyka
Stanislav Motyka
Wolfgang BognerWolfgang Bogner
Wolfgang Bogner
Objectives: Available clinical magnetic resonance spectroscopic imaging (MRSI) sequences are hampered by long scan times, low spatial resolution, strong field inhomogeneities, limited volume coverage, and low signal-to-noise ratio. High-resolution, whole-brain mapping of more metabolites than just N-acetylaspartate, choline, and creatine within clinically attractive scan times is urgently needed for clinical applications. The aim is therefore to develop a free induction decay (FID) MRSI sequence with rapid concentric ring trajectory (CRT) encoding for 7 T and demonstrate its clinical feasibility for mapping the whole cerebrum of healthy volunteers and patients. Materials and Methods: Institutional review board approval and written informed consent were obtained. Time-efficient, 3-dimensional encoding of an ellipsoidal k-space by in-plane CRT and through-plane phase encoding was integrated into an FID-MRSI sequence. To reduce scan times further, repetition times were shortened, and variable temporal interleaves were applied. Measurements with different matrix sizes were performed to validate the CRT encoding in a resolution phantom. One multiple sclerosis patient, 1 glioma patient, and 6 healthy volunteers were prospectively measured. For the healthy volunteers, brain segmentation was performed to quantify median metabolic ratios, Cramér-Rao lower bounds (CRLBs), signal-to-noise ratios, linewidths, and brain coverage among all measured matrix sizes ranging from a 32 × 32 × 31 matrix with 6.9 × 6.9 × 4.2 mm3 nominal voxel size acquired in ~3 minutes to an 80 × 80 × 47 matrix with 2.7 × 2.7 × 2.7 mm3 nominal voxel size in ~15 minutes for different brain regions. Results: Phantom structures with diameters down to 3 to 4 mm were visible. In vivo MRSI provided high spectral quality (median signal-to-noise ratios, >6.3 and linewidths, <0.082 ppm) and fitting quality. Cramér-Rao lower bounds were ranging from less than 22% for glutamine (highest CRLB in subcortical gray matter) to less than 9.5% for N-acetylaspartate for the 80 × 80 × 47 matrix (highest CRLB in the temporal lobe). This enabled reliable mapping of up to 8 metabolites (N-acetylaspartate, N-acetylaspartyl glutamate, total creatine, glutamine, glutamate, total choline, myo-inositol, glycine) and macromolecules for all resolutions. Coverage of the whole cerebrum allowed visualization of the full extent of diffuse and local multiple sclerosis-related neurochemical changes (eg, up to 100% increased myo-inositol). Three-dimensional brain tumor metabolic maps provided valuable information beyond that of single-slice MRSI, with up to 200% higher choline, up to 100% increased glutamine, and increased glycine in tumor tissue. Conclusions: Seven Tesla FID-MRSI with time-efficient CRT readouts offers clinically attractive acquisition protocols tailored either for speed or for the investigation of small pathologic details and low-abundant metabolites. This can complement clinical MR studies of various brain disorders. Significant metabolic anomalies were demonstrated in a multiple sclerosis and a glioma patient for myo-inositol, glutamine, total choline, glycine, and N-acetylaspartate concentrations.

1 November 2015 in NeuroImage
Verified
Journal Article
Open access
MPMichal Považan
Michal Považan
GHGilbert Hangel
Gilbert Hangel
BSBernhard Strasser
Bernhard Strasser
SGStephan Gruber
Stephan Gruber
MCMarek Chmelik
Marek Chmelik
Wolfgang BognerWolfgang Bogner
Wolfgang Bogner
Long echo time (TE) MR spectroscopy (MRS) sequences are sensitive only to metabolites of low molecular weight. At shorter TE, significantly more metabolite signals are detectable, including broad signals of high-molecular-weight macromolecules (MMs). Although the presence of MM resonances can bias metabolite quantification at short TE, proper quantification of MMs is important since MMs themselves may serve as potentially valuable biomarkers for many pathologies. We have therefore developed an FID-based 2D-MR Spectroscopic Imaging (2D-MRSI) sequence to map MMs in healthy brain tissue at 7 T within a scan time of ~17 min and a repetition time of 879 ms. This 2D-MRSI technique provides MM maps over a whole slice (i.e., including cortical gray matter) at an ultra-short acquisition delay of 1.3 ms, using double inversion for efficient nulling of low-molecular-weight metabolites. The optimal sequence parameters were estimated using Bloch simulations, phantom testing, and in vivo validation. The acquired in vivo MM spectra (n=6) included nine distinct MM peaks in the range of ~0.9-3.7 ppm. The measured average MM spectrum was incorporated into the LCModel basis set and utilized for further quantification of MRSI data sets without metabolite nulling, which were acquired in five additional volunteers. The quantification results for two basis sets, one including the MMs and one without MM spectrum, were compared. Due to the high spectral resolution and full signal detection provided by the FID-MRSI sequence, we could successfully map five important brain metabolites. Most quantified metabolite signal amplitudes were significantly lower since the inclusion of MMs into the basis set corrected the overestimation of metabolite signals. The precision of fit (i.e., Cramér Rao lower bounds) remained unchanged. Our MM maps show that the overall MM contribution was higher in gray matter than in white matter. In conclusion, the acquired MM spectrum improved the accuracy of metabolite quantification and allowed the acquisition of high spatial resolution maps of five major brain metabolites and also MMs.

3 March 2023 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
LHLydiane Hirschler
Lydiane Hirschler
Nico SollmannNico Sollmann
Nico Sollmann
BSBárbara Schmitz‐Abecassis
Bárbara Schmitz‐Abecassis
JPJoana Pinto
Joana Pinto
FAFatemehsadat Arzanforoosh
Fatemehsadat Arzanforoosh
GHGilbert Hangel
Gilbert Hangel
Preoperative clinical magnetic resonance imaging (MRI) protocols for gliomas, brain tumors with dismal outcomes due to their infiltrative properties, still rely on conventional structural MRI, which does not deliver information on tumor genotype and is limited in the delineation of diffuse gliomas. The GliMR COST action wants to raise awareness about the state of the art of advanced MRI techniques in gliomas and their possible clinical translation or lack thereof. This review describes current methods, limits, and applications of advanced MRI for the preoperative assessment of glioma, summarizing the level of clinical validation of different techniques. In this first part, we discuss dynamic susceptibility contrast and dynamic contrast‐enhanced MRI, arterial spin labeling, diffusion‐weighted MRI, vessel imaging, and magnetic resonance fingerprinting. The second part of this review addresses magnetic resonance spectroscopy, chemical exchange saturation transfer, susceptibility‐weighted imaging, MRI‐PET, MR elastography, and MR‐based radiomics applications.Evidence Level: 3Technical Efficacy: Stage 2

9 October 2019 in Frontiers in Oncology
Verified
Journal Article
Open access
PDF file
ZIZohaib Iqbal
Zohaib Iqbal
DNDan Nguyen
Dan Nguyen
GHGilbert Hangel
Gilbert Hangel
SMStanislav Motyka
Stanislav Motyka
Wolfgang BognerWolfgang Bogner
Wolfgang Bogner
SJSteve Jiang
Steve Jiang
Magnetic resonance spectroscopic imaging (SI) is a unique imaging technique that provides biochemical information from in vivo tissues. The 1H spectra acquired from several spatial regions are quantified to yield metabolite concentrations reflective of tissue metabolism. However, since these metabolites are found in tissues at very low concentrations, SI is often acquired with limited spatial resolution. In this work, we test the hypothesis that deep learning is able to upscale low resolution SI, together with the T1-weighted (T1w) image, to reconstruct high resolution SI. We report on a novel densely connected UNet (D-UNet) architecture capable of producing super-resolution spectroscopic images. The inputs for the D-UNet are the T1w image and the low resolution SI image while the output is the high resolution SI. The results of the D-UNet are compared both qualitatively and quantitatively to simulated and in vivo high resolution SI. It is found that this deep learning approach can produce high quality spectroscopic images and reconstruct entire 1H spectra from low resolution acquisitions, which can greatly advance the current SI workflow.