Khalid Mohammed Sumaily

Dr. Khalid Mohammed Sumaily

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 February 2022 in Medicina
Verified
Journal Article
Open access
PDF file
ESEssa M Sabi
Essa M Sabi
Lotfi Saeed Bin DahmanLotfi Saeed Bin Dahman
Lotfi Saeed Bin Dahman
AMAbdul Khader Mohammed
Abdul Khader Mohammed
KSKhalid Mohammed Sumaily
Khalid Mohammed Sumaily
Nasser M Al-DaghriNasser M Al-Daghri
Nasser M Al-Daghri
Background and Objectives: In this study, we aimed to investigate the link between common -2548G>A (rs7799039) promoter variant of the human leptin gene (LEP) with leptin and serum glucose leptin levels in obese Saudi patients. Materials and Methods: A total of 206 Saudi adults (80 obese normotensive nondiabetics, 76 obese hypertensive with Type 2 Diabetes and 50 normotensive nondiabetic controls) were genotyped for -2548G>A LEP polymorphism using the polymerase chain reaction-restriction fragment-length polymorphism technique. Results: Participants with minor AA genotype had significantly higher blood glucose levels (6.8 ± 0.55 mmol/L vs. 5.8 ± 0.30 mmol/L; p < 0.04) and HOMA-IR (4.1 ± 0.84 vs. 2.6 ± 0.67; p = 0.03) against those carrying major GG genotype. Participants with heterozygous GA genotype had significantly higher serum leptin levels against those carrying major GG genotype (40.0 ± 2.6 ng/mL vs. 29.6 ± 2.6 ng/mL; p = 0.04). Further investigation showed that individuals with AA, GA, GA + AA genotypes are at greater risk of developing hyperglycemia compared to those with GG genotype [OR 3.7(1.6–8.4), p = 0.001; 3.2 (1.2–8.6), p = 0.03; 3.5 (1.6–7.7), p = 0.001, respectively]. Additionally, the -2548AA allele was shown to be a risk factor for hyperglycemia [OR 1.9 (1.2–3.0), p = 0.006]. Our data revealed no relationship between this variant of the LEP gene with systolic and diastolic BP, signifying that this genetic variant is not a significant marker of obesity and hypertension in the Saudi population. Conclusions: AA and GA genotypes and LEP gene -2548AA alleles may signify potent risk factors predisposing healthy individuals to develop T2DM regardless of blood-pressure profile.

27 January 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
Lotfi Saeed Bin DahmanLotfi Saeed Bin Dahman
Lotfi Saeed Bin Dahman
KSKhalid Mohammed Sumaily
Khalid Mohammed Sumaily
ESEssa M Sabi
Essa M Sabi
MHMohammed Hassan
Mohammed Hassan
ATAbeer M. Bin Thalab
Abeer M. Bin Thalab
FAFatima M. Alhadhrmi
Fatima M. Alhadhrmi
Different laboratory methods are used to measure serum ferritin levels as a marker of iron status in the general population. This study aimed to compare serum ferritin levels using enzyme-linked immunosorbent assay (ELISA) versus immunochemiluminescence (Cobas e411) and immunoturbidimetric (Cobas Integra 400) methods in terms of sensitivity, specificity and accuracy, and whether they can be used interchangeably. A comparative cross-sectional study enrolled one hundred and six adult Yemeni patients (33 males and 73 females) aged 18–55 years, recruited from the dermatology and cosmetic center of Hadhramout Modern Hospital, Mukalla, Yemen. Serum ferritin levels were measured using ELISA, Cobas e411, and Cobas Integra 400 methods. For method comparison, a paired-sample t-test was used. For the consistency between the three methods, they were analyzed with regression and Pearson correlation coefficient. For determining accuracy, a receiver operating curve (ROC) was used. Bias error between the methods was determined through a Bland–Altman plot analysis. Our results did not show any significant statistical difference between ELISA and Cobas e411 (52.55 ± 7.4 µg/L vs. 52.58 ± 7.5 µg/L, p = 0.967), while there were significantly higher values from Cobas Integra 400 results than Cobas e411 (56.31 ± 7.8 µg/L vs. 52.58 ± 7.5 µg/L, p < 0.001) and ELISA (52.55 ± 7.4 µg/L vs. 56.31 ± 7.8 µg/L, p < 0.001). According to the correlation coefficient and linear regression analysis, a strong association between ELISA with Cobas e411 (r = 0.993, p < 0.001) and Cobas Integra 400 results (r = 0.994, p < 0.001) were revealed. For determining accuracy, Cobas e411 and Cobas Integra 400 results showed higher sensitivity (92.0%; 90.0%) and specificity (97.7%; 99.9%) respectively. Additionally, the Bland–Altman plot analysis showed a high agreement between the ELISA and Cobas e411 methods (bias: −0.035). In contrast, there was a low agreement between the ELISA and Cobas Integra 400 methods (bias: −3.75). Similarly, the agreement between Cobas e411 and Cobas Integra 400 methods was low (bias: −3.72). Serum ferritin levels were measured by Cobas e411, and Cobas Integra 400 methods were strongly correlated with the ELISA results, with higher sensitivity, specificity, and accuracy. However, further investigations with larger samples are required for improved accuracy and more precise results, and to determine whether they can be used interchangeably.

Verified
Journal Article
Open access
PDF file
DDDev Desai
Dev Desai
ASAbhijay Shah
Abhijay Shah
JCJoseph Rem Cebuma Dela Cruz
Joseph Rem Cebuma Dela Cruz
TMTayba Mugibel
Tayba Mugibel
KSKhalid Mohammed Sumaily
Khalid Mohammed Sumaily
Lotfi Saeed Bin DahmanLotfi Saeed Bin Dahman
Lotfi Saeed Bin Dahman
Background: Pneumonia is a ubiquitous health condition with severe outcomes. The advancement of ultrasonography techniques allows its application in evaluating pulmonary diseases, providing safer and accessible bedside therapeutic decisions compared to chest X-ray and chest computed tomography (CT) scan. Because of its aforementioned benefits, we aimed to confirm the diagnostic accuracy of lung ultrasound (LUS) for pneumonia in adults. Methods: A systematic literature search was performed of Medline, Cochrane and Crossref, independently by two authors. The selection of studies proceeded based on specific inclusion and exclusion criteria without restrictions to particular study designs, language or publication dates and was followed by data extraction. The gold standard reference in the included studies was chest X-ray/CT scan or both. Results: Twenty-nine (29) studies containing 6702 participants were included in our meta-analysis. Pooled sensitivity, specificity and PPV were 92% (95% CI: 91–93%), 94% (95% CI: 94 to 95%) and 93% (95% CI: 89 to 96%), respectively. Pooled positive and negative likelihood ratios were 16 (95% CI: 14 to 19) and 0.08 (95% CI: 0.07 to 0.09). The area under the ROC curve of LUS was 0. 9712. Conclusions: LUS has high diagnostic accuracy in adult pneumonia. Its contribution could form an optimistic clue in future updates considering this condition.

Verified
Journal Article
Open access
PDF file
MJMinnie Jacob
Minnie Jacob
RNRefat Musa Nimer
Refat Musa Nimer
MAMohamad S. Alabdaljabar
Mohamad S. Alabdaljabar
ESEssa M Sabi
Essa M Sabi
MAMysoon M. Al-Ansari
Mysoon M. Al-Ansari
ARAnas Abdel Rahman
Anas Abdel Rahman
Nephrotic syndrome (NS) is a kidney illness characterized by excessive proteinuria, hypoalbuminemia, edema, and hyperlipidemia, which may lead to kidney failure and necessitate renal transplantation. End-stage renal disease, cardiovascular issues, and mortality are much more common in those with NS. Therefore, the present study aimed to identify potential new biomarkers associated with the pathogenesis and diagnosis of NS. The liquid chromatography–mass spectrometry (LC–MS) metabolomics approach was applied to profile the metabolome of human serum of patients with NS. A total of 176 metabolites were significantly altered in NS compared to the control. Arginine, proline, and tryptophan metabolism; arginine, phenylalanine, tyrosine, and tryptophan biosynthesis were the most common metabolic pathways dysregulated in NS. Furthermore, alanyl-lysine and isoleucyl-threonine had the highest discrimination between NS and healthy groups. The candidate biomarkers may lead to understanding the possible metabolic alterations associated with NS and serve as potential diagnostic biomarkers.

24 June 2022 in Nutrients
Verified
Journal Article
Open access
PDF file
KSKhalid Mohammed Sumaily
Khalid Mohammed Sumaily
A trace element is a chemical element with a concentration (or other measures of an amount) that is very low. The essential TEs, such as copper (Cu), selenium (Se), zinc (Zn), iron (Fe) and the electrolyte magnesium (Mg) are among the most commonly studied micronutrients. Each element has been shown to play a distinctive role in human health, and TEs, such as iron (Fe), zinc (Zn) and copper (Cu), are among the essential elements required for the organisms’ well-being as they play crucial roles in several metabolic pathways where they act as enzyme co-factors, anti-inflammatory and antioxidant agents. Epidemics of infectious diseases are becoming more frequent and spread at a faster pace around the world, which has resulted in major impacts on the economy and health systems. Different trace elements have been reported to have substantial roles in the pathogenesis of viral infections. Micronutrients have been proposed in various studies as determinants of liver disorders, COVID-19 and T2DM risks. This review article sheds light on the roles and mechanisms of micronutrients in the pathogenesis and prevention of chronic hepatitis B, C and E, as well as Coronavirus-19 infection and type-2 diabetes mellitus. An update on the status of the aforementioned micronutrients in pre-clinical and clinical settings is also briefly summarized.

7 June 2022 in Molecules
Verified
Journal Article
Open access
PDF file
RNRefat Musa Nimer
Refat Musa Nimer
KSKhalid Mohammed Sumaily
Khalid Mohammed Sumaily
AMArwa Al muslat
Arwa Al muslat
MJMai Abdel Jabar
Mai Abdel Jabar
ESEssa M Sabi
Essa M Sabi
ARAnas Abdel Rahman
Anas Abdel Rahman
Duchenne muscular dystrophy (DMD) is an X-linked recessive disorder characterized by progressive muscle loss, leading to difficulties in movement. Mutations in the DMD gene that code for the protein dystrophin are responsible for the development of DMD disorder, where the synthesis of this protein is completely halted. Therefore, circulating dystrophin protein could be a promising biomarker of DMD disease. Current methods for diagnosing DMD have sensitivity, specificity, and reproducibility limitations. Herein, a quantitative liquid chromatography–tandem spectrometry (LC–MS/MS) technique in multiple reaction monitoring (MRM) mode was designed and validated for accurate dystrophin protein measurement in a dried blood spot (DBS). The method was successfully validated on the basis of international guidelines regarding calibration curves, precision, and accuracy. In addition, patients and healthy controls were used to test the amount of dystrophin protein circulating in DBS samples as a potential biomarker for DMD disorders. DMD patients were found to have considerably lower levels than controls. To the best of our knowledge, this is the first study to report dystrophin levels in DBS through LC–MS/MS as a diagnostic marker for DMD to the proposed MRM method, providing a highly specific and sensitive approach to dystrophin quantification in a DBS that can be applied in DMD screening.