Volodymyr Gurey

Prof. Dr. Volodymyr Gurey

Lviv Polytechnic National University, Lviv, L’vivs’ka Oblast’, Ukraine
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 January 2023 in Coatings
Verified
Journal Article
Open access
PDF file
VKVolodymyr Kyryliv
Volodymyr Kyryliv
OMOlha Maksymiv
Olha Maksymiv
Volodymyr GureyVolodymyr Gurey
Volodymyr Gurey
IHIhor Hurey
Ihor Hurey
YKYaroslav Bogdanovych Kyryliv
Yaroslav Bogdanovych Kyryliv
Olha ZvirkoOlha Zvirko
Olha Zvirko
A surface nanocrystalline steel layer in the low alloy steel 41Cr4 was fabricated by using mechanical-pulse treatment (MPT) with different deformation modes. The structure parameters, the physical and mechanical properties, the wear resistance, and the surface topography parameters of the treated steel depending on the deformation mode were investigated. A tool with a smooth working surface was used for inducing unidirectional deformation in the top surface layer (shear), and a tool with the oppositely directed grooves was used for generating multidirectional deformation. The surface layer with a nanocrystalline structure formed by MPT using both of the tools was characterised by enhanced mechanical properties and wear resistance compared with those of the untreated or heat-treated steels. Inducing multidirectional deformation during the MPT resulted in a decrease in the grain size and an increase in the depth and microhardness of the surface layer due to it facilitating the generation of dislocations compared to those formed under unidirectional deformation. The results also demonstrated that favourable surface topography parameters providing the highest wear resistance of the steel were obtained at MPT using multidirectional deformation.

Volodymyr GureyVolodymyr Gurey
Volodymyr Gurey
Pavlo MaruschakPavlo Maruschak
Pavlo Maruschak
IHIhor Hurey
Ihor Hurey
Volodymyr DzyuraVolodymyr Dzyura
Volodymyr Dzyura
THTetyana Hurey
Tetyana Hurey
WWWeronika Wojtowicz
Weronika Wojtowicz
Thermo-deformation treatment refers to methods of strengthening during which strengthened layers with a nanocrystalline structure are formed in the surface layers by modifying the metal surface layer, which changes its phase and structural and chemical compositions, reduces grain size, and improves performance. Grinding of the metal structure was achieved by combining two methods simultaneously during this treatment: the action of a highly concentrated energy source on the surface layer and intense plastic deformation. The source of highly concentrated energy was generated in the contact zone of the tool-disc, which rotates at high speed during friction on the treated surface. Intense deformation was achieved due to the grooves on the tool’s working surface. Dynamic analysis of the thermo-deformation treatment process of flat surfaces of machine parts and a calculation scheme of the surface grinder machine’s elastic system, which is the three-mass model, were developed. When the groove width increased from 4 mm to 8 mm, the force amplitude in the contact zone increased from 10 N to 75 N. Accordingly, the thickness of the nanocrystalline layer increased from 190–220 μm to 250–260 μm, and its hardness increased from 9.3 GPa to 11.1 GPa.



25 November 2023 in Vibroengineering PROCEDIA
Verified
Journal Article
Open access
PDF file
Vitaliy KorendiyVitaliy Korendiy
Vitaliy Korendiy
OPOleh Parashchyn
Oleh Parashchyn
VHVolodymyr Heletiy
Volodymyr Heletiy
VPViacheslav Pasika
Viacheslav Pasika
Volodymyr GureyVolodymyr Gurey
Volodymyr Gurey
NMNadiia Maherus
Nadiia Maherus
Vibration exciters are of most important units of any vibratory equipment defining its design peculiarities, operational features, functional purpose, and performance characteristics. Among a great variety of vibration exciters, the unbalanced rotors are of the most widely used. The present research considers the possibilities of providing specific motion trajectories of the vibratory machines’ working members with the help of the planetary-type vibration exciter. The methodology of this study is divided into two main stages: deriving motion equations of an unbalanced mass located on a planet gear and analyzing the possibilities of generating rectilinear, elliptical, and circular motion paths by choosing the appropriate geometrical parameters of the planetary gear train. The results of the performed kinematic analysis are presented in the form of the unbalanced mass trajectories, velocities, and accelerations at different design parameters of the planetary-type mechanism. The main scientific novelty of the present study is substantiating the possibilities of using the single-degree-of-freedom planetary-type mechanism for generating the controllable motion trajectories of the unbalanced mass of an inertial vibration exciter. The obtained results can be practically implemented while developing novel adjustable drives for various vibratory equipment, particularly compactors, sieves, screens, and conveyors.

24 September 2023 in Lubricants
Verified
Journal Article
Open access
PDF file
IHIhor Hurey
Ihor Hurey
Pavlo MaruschakPavlo Maruschak
Pavlo Maruschak
Andy AugoustiAndy Augousti
Andy Augousti
AFAlan Flowers
Alan Flowers
Volodymyr GureyVolodymyr Gurey
Volodymyr Gurey
Olegas PrentkovskisOlegas Prentkovskis
Olegas Prentkovskis
During the TDT of 41Cr4 steel specimens, a uniformly reinforced white layer with a nano-crystalline structure is formed in the surface layers. The wear resistance of sliding friction without the lubrication of a pair of steel 41Cr4—grey cast iron EN-GJL-200 (EN) under the face-to-face (“ring-ring”) scheme has been studied. It is revealed that when the sliding velocity changes from 0.25 m/s to 4 m/s and the unit load changes from 0.2 MPa to 1.0 MPa, a pair with a reinforced surface layer on 41Cr4 steel specimens and unreinforced specimens of EN-GJL-200 (EN) grey cast iron has a higher wear resistance than an unreinforced pair. The wear resistance increases for both reinforced and not reinforced specimens operating in a friction pair.