In this study, single, mix, multilayer Polyvinyl alcohol (PVA) electrospun nanofibers with epidermal growth factor (EGF) and fibroblast growth factor (FGF) were fabricated and characterized as a biological wound dressing scaffolds. The biological activities of the synthesized scaffolds have been verified by in vitro and in vivo studies. The chemical composition finding showed that the identified functional units within the produced nanofibers (O–H and N–H bonds) are attributed to both growth factors (GFs) in the PVA nanofiber membranes. Electrospun nanofibers' morphological features showed long protrusion and smooth morphology without beads and sprayed with an average range of 198–286 nm fiber diameter. The fiber diameters decrement and the improvement in wettability and surface roughness were recorded after GFs incorporated within the PVA Nanofibers, which indicated potential good adoption as biological dressing scaffolds due to the identified mechanical properties (Young’s modulus) in between 18 and 20 MPa. The MTT assay indicated that the growth factor release from the PVA nanofibers has stimulated cell proliferation and promoted cell viability. In the cell attachment study, the GFs incorporated PVA nanofibers stimulated cell proliferation and adhered better than the PVA control sample and presented no cytotoxic effect. The in vivo studies showed that compared to the control and single PVA-GFs nanofiber, the mix and multilayer scaffolds gave a much more wound reduction at day 7 with better wound repair at day 14–21, which indicated to enhancing tissue regeneration, thus, could be a projected as a suitable burn wound dressing scaffold.
In this work, a three-component reaction of 3-acetyl-4-hydroxycoumarine, malononitrile, or cyanoacetate in the presence of ammonium acetate was used to form coumarin derivatives. The chemical structures of new compounds were identified by 1H, 13C NMR and an elemental analysis. These compounds were examined in vitro for their antimicrobial activity against a panel of bacterial strains. In addition, these compounds were investigated for antioxidant activities by superoxideradical, DPPH (2,2-Diphenyl-1-picrylhydrazyl), and hydroxyl radical scavenging assays, in which most of them displayed significant antioxidant activities. Furthermore, these compounds were evaluated for anti-inflammatory activity by indirect hemolytic and lipoxygenase inhibition assays and revealed good activity. In addition, screening of the selected compounds 2–4 against colon carcinoma cell lines (HCT-116) and hepatocellular carcinoma cell lines (HepG-2) showed that that 2-amino-4-hydroxy-6-(4-hydroxy-2-oxo-2H-chromen-3-yl)nicotinonitrile 4 exhibited good cytotoxic activity against standard Vinblastine, while the other compounds exhibited moderate cytotoxic activity. Docking simulation showed that2-amino-4-hydroxy-6-(4-hydroxy-2-oxo-2H-chromen-3-yl)nicotinonitrile 4 is an effective inhibitor of the tumor protein HCT-116. A large fluorescence enhancement in a highly acidic medium was observed, and large fluorescence quenching by the addition of traces of Cu2+ and Ni2+ was also remarked.
1 November 2018 in Annals of Anatomy - Anatomischer Anzeiger
Nanofibers have obtained considerable interest for use in various applications. Polyvinyl alcohol (PVA) has been used to achieve many benefits for diverse pharmaceutical and biomedical applications. We investigated in this study the effects of applied voltage, needle diameter, and flow rate on morphologies of PVA nanofibers. A constant volume of the feeding solutions delivered to the needle at a flow rate of 1 and 2 mL/h with high potentials of voltage was applied as they exit the needle. After that, the electrospun fibers collected on the ground connected aluminum foil. The electrical conductivity measurements of feeding solutions performed at room temperature. Characterization of the PVA nanofibers conducted using scanning electron microscopy (SEM) and attenuated total reflectance-Fourier transform infrared spectroscopy (ATR-FTIR). The obtained nanofibers SEM images show beads when using the flow rate at 1 mL/h, whereas increasing the voltage and the flow rate improved the morphology of the nanofibers to uniform without beads. The FTIR results show that O-H and C-O bands are the main attributing to the chemical functionality of PVA nanofibers. As a conclusion, the high voltage and flow rate considered as the most critical parameters that impacted on PVA nanofibers morphology.
1 May 2019 in Chemical and Pharmaceutical Bulletin
Electrodeposition is commonly used to deposit ceramic or metal coating on metallic implants. Its utilization in depositing polymer microcapsule coating is currently being explored. However, there is no encapsulation of drug within polymer microcapsules that will enhance its chemical and biological properties. Therefore, in this study, ginseng which is known for its multiple therapeutic effects was encapsulated inside biodegradable poly(lactic-co-glycolic acid) (PLGA) microcapsules to be coated on pre-treated medical grade stainless steel 316L (SS316L) using an electrodeposition technique. Polyaniline (PANI) was incorporated within the microcapsules to drive the formation of microcapsule coating. The electrodeposition was performed at different current densities (1–3 mA) and different deposition times (20–60 s). The chemical composition, morphology and wettability of the microcapsule coatings were characterized through attenuated total reflectance-Fourier transform infrared spectroscopy (ATR-FTIR), scanning electron microscopy (SEM) and contact angle analyses. The changes of electrolyte colors, before and after the electrodeposition were also observed. The addition of PANI has formed low wettability and uniform microcapsule coatings at 2 mA current density and 40 s deposition time. Reduction in the current density or deposition time caused less attachment of microcapsule coatings with high wettability records. While prolonging either one parameter has led to debris formation and melted microcapsules with non-uniform wettability measurements. The color of electrolytes was also changed from milky white to dark yellow when the current density and deposition time increased. The application of tolerable current density and deposition time is crucial to obtain a uniform microcapsule coating, projecting a controlled release of encapsulated drug.