Andrea Kronfeld

Dr. Andrea Kronfeld

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 September 2017 in eLife
Verified
Journal Article
Open access
MSMiriam Schwalm
Miriam Schwalm
FSFlorian Schmid
Florian Schmid
LWLydia Wachsmuth
Lydia Wachsmuth
HBHendrik Backhaus
Hendrik Backhaus
AKAndrea Kronfeld
Andrea Kronfeld
ASAlbrecht Stroh
Albrecht Stroh
Spontaneous slow oscillation-associated slow wave activity represents an internally generated state which is characterized by alternations of network quiescence and stereotypical episodes of neuronal activity - slow wave events. However, it remains unclear which macroscopic signal is related to these active periods of the slow wave rhythm. We used optic fiber-based calcium recordings of local neural populations in cortex and thalamus to detect neurophysiologically defined slow calcium waves in isoflurane anesthetized rats. The individual slow wave events were used for an event-related analysis of simultaneously acquired whole-brain BOLD fMRI. We identified BOLD responses directly related to onsets of slow calcium waves, revealing a cortex-wide BOLD correlate: the entire cortex was engaged in this specific type of slow wave activity. These findings demonstrate a direct relation of defined neurophysiological events to a specific BOLD activity pattern and were confirmed for ongoing slow wave activity by independent component and seed-based analyses.

12 October 2020 in Cancers
Verified
Journal Article
Open access
PDF file
DKDarius Kalasauskas
Darius Kalasauskas
AKAndrea Kronfeld
Andrea Kronfeld
MRMirjam Renovanz
Mirjam Renovanz
EKElena Kurz
Elena Kurz
PLPetra Leukel
Petra Leukel
NKNaureen Keric
Naureen Keric
Up to 60% of atypical meningiomas (World Health Organization (WHO) grade II) reoccur within 5 years after resection. However, no clear radiological criteria exist to identify tumors with higher risk of relapse. In this study, we aimed to assess the association of certain radiomic and semantic features of atypical meningiomas in MRI with tumor recurrence. We identified patients operated on primary atypical meningiomas in our department from 2007 to 2017. An analysis of 13 quantitatively defined radiomic and 11 qualitatively defined semantic criteria was performed based on preoperative MRI scans. Imaging characteristics were assessed along with clinical and survival data. The analysis included 76 patients (59% women, mean age 59 years). Complete tumor resection was achieved in 65 (86%) cases, and tumor relapse occurred in 17 (22%) cases. Mean follow-up time was 41.6 (range 3–168) months. Cystic component was significantly associated with tumor recurrence (odds ratio (OR) 21.7, 95% confidence interval (CI) 3.8–124.5) and shorter progression-free survival (33.2 vs. 80.7 months, p < 0.001), whereas radiomic characteristics had no predictive value in univariate analysis. However, multivariate analysis demonstrated significant predictive value of high cluster prominence (hazard ratio (HR) 5.89 (1.03–33.73) and cystic component (HR 20.21 (2.46–166.02)) for tumor recurrence. The combination of radiomic and semantic features might be an effective tool for identifying patients with high-risk atypical meningiomas. The presence of a cystic component in these tumors is associated with a high risk of tumor recurrence.

24 April 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
SASebastian Altmann
Sebastian Altmann
MMMario A. Abello Mercado
Mario A. Abello Mercado
FUFelix A. Ucar
Felix A. Ucar
AKAndrea Kronfeld
Andrea Kronfeld
BABilal Al-Nawas
Bilal Al-Nawas
A(Ahmed Othman (MD)
Ahmed Othman (MD)
Objectives: To assess the benefits of ultra-high-resolution CT (UHR-CT) with deep learning–based image reconstruction engine (AiCE) regarding image quality and radiation dose and intraindividually compare it to normal-resolution CT (NR-CT). Methods: Forty consecutive patients with head and neck UHR-CT with AiCE for diagnosed head and neck malignancies and available prior NR-CT of a different scanner were retrospectively evaluated. Two readers evaluated subjective image quality using a 5-point Likert scale regarding image noise, image sharpness, artifacts, diagnostic acceptability, and assessability of various anatomic regions. For reproducibility, inter-reader agreement was analyzed. Furthermore, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and slope of the gray-value transition between different tissues were calculated. Radiation dose was evaluated by comparing CTDIvol, DLP, and mean effective dose values. Results: UHR-CT with AiCE reconstruction led to significant improvement in subjective (image noise and diagnostic acceptability: p < 0.000; ICC ≥ 0.91) and objective image quality (SNR: p < 0.000; CNR: p < 0.025) at significantly lower radiation doses (NR-CT 2.03 ± 0.14 mSv; UHR-CT 1.45 ± 0.11 mSv; p < 0.0001) compared to NR-CT. Conclusions: Compared to NR-CT, UHR-CT combined with AiCE provides superior image quality at a markedly lower radiation dose. With improved soft tissue assessment and potentially improved tumor detection, UHR-CT may add further value to the role of CT in the assessment of head and neck pathologies.

8 February 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
A(Ahmed Othman (MD)
Ahmed Othman (MD)
MMMario Alberto Abello Mercado
Mario Alberto Abello Mercado
SASebastian Altmann
Sebastian Altmann
FRFlorian Ringel
Florian Ringel
CBChristian Booz
Christian Booz
A(Ahmed Othman (MD)
Ahmed Othman (MD)
Purpose: To evaluate the effects of single-energy metal artifact reduction (SEMAR) on image quality of ultra-high-resolution CT-angiography (UHR-CTA) with intracranial implants after aneurysm treatment. Methods: Image quality of standard and SEMAR-reconstructed UHR-CT-angiography images of 54 patients who underwent coiling or clipping was retrospectively evaluated. Image noise (i.e., index for metal-artifact strength) was analyzed in close proximity to and more distally from the metal implant. Frequencies and intensities of metal artifacts were additionally measured and intensity-differences between both reconstructions were compared in different frequencies and distances. Qualitative analysis was performed by two radiologists using a four-point Likert-scale. All measured results from both quantitative and qualitative analysis were then compared between coils and clips. Results: Metal artifact index (MAI) and the intensity of coil-artifacts were significantly lower in SEMAR than in standard CTA in close vicinity to and more distally from the coil-package (p < 0.001, each). MAI and the intensity of clip-artifacts were significantly lower in close vicinity (p = 0.036; p < 0.001, respectively) and more distally from the clip (p = 0.007; p < 0.001, respectively). In patients with coils, SEMAR was significantly superior in all qualitative categories to standard images (p < 0.001), whereas in patients with clips, only artifacts were significantly less (p < 0.05) for SEMAR. Conclusion: SEMAR significantly reduces metal artifacts in UHR-CT-angiography images with intracranial implants and improves image quality and diagnostic confidence. SEMAR effects were strongest in patients with coils, whereas the effects were minor in patients with titanium-clips due to the absent of or minimal artifacts.

1 December 2015 in Medical Physics
Verified
Journal Article
Closed access
AKAndrea Kronfeld
Andrea Kronfeld
HBHans‐Georg Buchholz
Hans‐Georg Buchholz
SMStephan Maus
Stephan Maus
SRStefan Reuss
Stefan Reuss
WMWibke Müller‐Forell
Wibke Müller‐Forell
IMIsabelle Miederer
Isabelle Miederer

Verified
Journal Article
Open access
PDF file
Sebastian R. RederSebastian R. Reder
Sebastian R. Reder
SLSteffen Lückerath
Steffen Lückerath
ANAxel Neulen
Axel Neulen
KBKatja Ute Beiser
Katja Ute Beiser
NGNils F. Grauhan
Nils F. Grauhan
AKAndrea Kronfeld
Andrea Kronfeld
(1) Background: To predict clinical outcomes in patients with aneurysmal subarachnoid hemorrhage (aSAH) and delayed cerebral ischemia (DCI) by assessment of the cerebral perfusion using a 2D perfusion angiography (2DPA) time–contrast agent (CA) concentration model. (2) Methods: Digital subtraction angiography (DSA) data sets of n = 26 subjects were acquired and post-processed focusing on changes in contrast density using a time–concentration model at three time points: (i) initial presentation with SAH (T0); (ii) vasospasm-associated acute clinical impairment (T1); and (iii) directly after endovascular treatment (T2) of SAH-associated large vessel vasospasm (LVV), which resulted in n = 78 data sets. Maximum slope (MS in SI/ms), time-to-peak (TTP in ms), and maximum amplitude of a CA bolus (dSI) were measured in brain parenchyma using regions of interest (ROIs). First, acquired parameters were standardized to the arterial input function (AIF) and then statistically analyzed as mean values. Additionally, data were clustered into two subsets consisting of patients with regredient or with stable/progredient symptoms (or Doppler signals) after endovascular treatment (n = 10 vs. n = 16). (3) Results: Perfusion parameters (MS, TTP, and dSI) differed significantly between T0 and T1 (p = 0.003 each). Significant changes between T1 and T2 were only detectable for MS (0.041 ± 0.016 vs. 0.059 ± 0.026; p = 0.011) in patients with regredient symptoms at T2 (0.04 ± 0.012 vs. 0.066 ± 0.031; p = 0.004). For dSI, there were significant differences between T0 and T2 (5095.8 ± 2541.9 vs. 3012.3 ± 968.3; p = 0.001), especially for those with stable symptoms at T2 (5685.4 ± 2967.2 vs. 3102.8 ± 1033.2; p = 0.02). Multiple linear regression analysis revealed that a) the difference in MS between T1 and T2 and b) patient’s age (R = 0.6; R2 = 0.34; p = 0.009) strongly predict the modified Rankin Scale (mRS) at discharge. (4) Conclusions: 2DPA allows the direct measurement of treatment effects in SAH associated DCI and may be used to predict outcomes in these critically ill patients.