Christian Booz

Dr. Christian Booz

Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, 60590 Frankfurt, Germany

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 October 2021 in European Radiology
Verified
Journal Article
Open access
PDF file
LGLeon D. Gruenewald
Leon D. Gruenewald
VKVitali Koch
Vitali Koch
SMSimon S. Martin
Simon S. Martin
IYIbrahim Yel
Ibrahim Yel
KEKatrin Eichler
Katrin Eichler
CBChristian Booz
Christian Booz
Objectives: To evaluate the predictive value of volumetric bone mineral density (BMD) assessment of the lumbar spine derived from phantomless dual-energy CT (DECT)-based volumetric material decomposition as an indicator for the 2-year occurrence risk of osteoporosis-associated fractures. Methods: L1 of 92 patients (46 men, 46 women; mean age, 64 years, range, 19–103 years) who had undergone third-generation dual-source DECT between 01/2016 and 12/2018 was retrospectively analyzed. For phantomless BMD assessment, dedicated DECT postprocessing software using material decomposition was applied. Digital files of all patients were sighted for 2 years following DECT to obtain the incidence of osteoporotic fractures. Receiver operating characteristic (ROC) analysis was used to calculate cut-off values and logistic regression models were used to determine associations of BMD, sex, and age with the occurrence of osteoporotic fractures. Results: A DECT-derived BMD cut-off of 93.70 mg/cm3 yielded 85.45% sensitivity and 89.19% specificity for the prediction to sustain one or more osteoporosis-associated fractures within 2 years after BMD measurement. DECT-derived BMD was significantly associated with the occurrence of new fractures (odds ratio of 0.8710, 95% CI, 0.091–0.9375, p < .001), indicating a protective effect of increased DECT-derived BMD values. Overall AUC was 0.9373 (CI, 0.867–0.977, p < .001) for the differentiation of patients who sustained osteoporosis-associated fractures within 2 years of BMD assessment. Conclusions: Retrospective DECT-based volumetric BMD assessment can accurately predict the 2-year risk to sustain an osteoporosis-associated fracture in at-risk patients without requiring a calibration phantom. Lower DECT-based BMD values are strongly associated with an increased risk to sustain fragility fractures. Key Points: •Dual-energy CT–derived assessment of bone mineral density can identify patients at risk to sustain osteoporosis-associated fractures with a sensitivity of 85.45% and a specificity of 89.19%. •The DECT-derived BMD threshold for identification of at-risk patients lies above the American College of Radiology (ACR) QCT guidelines for the identification of osteoporosis (93.70 mg/cm3 vs 80 mg/cm3).

1 February 2019 in Radiology
Verified
Journal Article
Closed access
CBChristian Booz
Christian Booz
JNJochen Nöske
Jochen Nöske
SMSimon S. Martin
Simon S. Martin
MAMoritz H. Albrecht
Moritz H. Albrecht
IYIbrahim Yel
Ibrahim Yel
JWJulian L. Wichmann
Julian L. Wichmann
Color-coded virtual noncalcium images optimized for the analysis of intervertebral disks show substantially higher diagnostic accuracy for the detection of lumbar disk herniation and spinal nerve root impingement in comparison to standard CT. PurposeTo assess the diagnostic performance of dual-energy CT with reconstruction of virtual noncalcium (VNCa) images for the detection of lumbar disk herniation compared with standard CT image reconstruction.Materials and MethodsFor this retrospective study, 41 patients (243 intervertebral disks; overall mean age, 68 years; 24 women [mean age, 68 years] and 17 men [mean age, 68 years]) underwent clinically indicated third-generation, dual-source, dual-energy CT and 3.0-T MRI within 2 weeks between March 2017 and January 2018. Six radiologists, blinded to clinical and MRI information, independently evaluated conventional grayscale dual-energy CT series for the presence and degree of lumbar disk herniation and spinal nerve root impingement. After 8 weeks, readers reevaluated examinations by using color-coded VNCa reconstructions. MRI evaluated by two separate experienced readers, blinded to clinical and dual-energy CT information, served as the standard of reference. Sensitivity and specificity were the pr...

1 September 2018 in European Journal of Radiology
Verified
Journal Article
Closed access
LLLukas Lenga
Lukas Lenga
RCRouben Czwikla
Rouben Czwikla
JWJulian L. Wichmann
Julian L. Wichmann
DLDoris Leithner
Doris Leithner
MAMoritz H. Albrecht
Moritz H. Albrecht
SMSimon S. Martin
Simon S. Martin

1 March 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
Daniel DillingerDaniel Dillinger
Daniel Dillinger
DODaniel Overhoff
Daniel Overhoff
CBChristian Booz
Christian Booz
HKHanns Leonhard Kaatsch
Hanns Leonhard Kaatsch
JPJoel Piechotka
Joel Piechotka
SWStephan Waldeck
Stephan Waldeck
Purpose: The novel photon-counting detector (PCD) technique acquires spectral data for virtual monoenergetic imaging (VMI) in every examination. The aim of this study was the evaluation of the impact of VMI of abdominal arterial vessels on quantitative and qualitative subjective image parameters. Methods: A total of 20 patients that underwent an arterial phase computed tomography (CT) scan of the abdomen with a novel PCD CT (Siemens NAEOTOM alpha) were analyzed regarding attenuation at different energy levels in virtual monoenergetic imaging. Contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) were calculated and compared between the different virtual monoenergetic (VME) levels with correlation to vessel diameter. In addition, subjective image parameters (overall subjective image quality, subjective image noise and vessel contrast) were evaluated. Results: Our research showed decreasing attenuation levels with increasing energy levels in virtual monoenergetic imaging regardless of vessel diameter. CNR showed best overall results at 60 keV, and SNR at 70 keV with no significant difference to 60 keV (p = 0.294). Subjective image quality was rated best at 70 keV for overall image quality, vessel contrast and noise. Conclusions: Our data suggest that VMI at 60–70 keV provides the best objective and subjective image quality concerning vessel contrast irrespective of vessel size.

2 July 2021 in European Radiology
Verified
Journal Article
Open access
PDF file
MCMarco Cavallaro
Marco Cavallaro
TDTommaso D'Angelo
Tommaso D'Angelo
MAMoritz H. Albrecht
Moritz H. Albrecht
IYIbrahim Yel
Ibrahim Yel
SMSimon S. Martin
Simon S. Martin
CBChristian Booz
Christian Booz
Objectives: To compare dual-energy CT (DECT) and MRI for assessing presence and extent of traumatic bone marrow edema (BME) and fracture line depiction in acute vertebral fractures. Methods: Eighty-eight consecutive patients who underwent dual-source DECT and 3-T MRI of the spine were retrospectively analyzed. Five radiologists assessed all vertebrae for presence and extent of BME and for identification of acute fracture lines on MRI and, after 12 weeks, on DECT series. Additionally, image quality, image noise, and diagnostic confidence for overall diagnosis of acute vertebral fracture were assessed. Quantitative analysis of CT numbers was performed by a sixth radiologist. Two radiologists analyzed MRI and grayscale DECT series to define the reference standard. Results: For assessing BME presence and extent, DECT showed high sensitivity (89% and 84%, respectively) and specificity (98% in both), and similarly high diagnostic confidence compared to MRI (2.30 vs. 2.32; range 0–3) for the detection of BME (p = .72). For evaluating acute fracture lines, MRI achieved high specificity (95%), moderate sensitivity (76%), and a significantly lower diagnostic confidence compared to DECT (2.42 vs. 2.62, range 0–3) (p < .001). A cutoff value of − 0.43 HU provided a sensitivity of 89% and a specificity of 90% for diagnosing BME, with an overall AUC of 0.96. Conclusions: DECT and MRI provide high diagnostic confidence and image quality for assessing acute vertebral fractures. While DECT achieved high overall diagnostic accuracy in the analysis of BME presence and extent, MRI provided moderate sensitivity and lower confidence for evaluating fracture lines. Key Points: • In the setting of spinal trauma, dual-energy CT (DECT) is highly accurate in the evaluation of acute vertebral fractures and bone marrow edema presence and extent. • MRI provides moderate sensitivity and lower diagnostic confidence for the depiction of acute fracture lines, when compared to DECT, which might result in potentially inaccurate and underestimated severity assessment of injuries in certain cases when no fracture lines are visible on MRI. • DECT may represent a valid imaging alternative to MRI in specific settings of acute spinal trauma and in follow-up examinations, especially in elderly or unstable patients and in cases of subtle or complex orientated fracture lines.

1 July 2019 in European Journal of Radiology
Verified
Journal Article
Closed access
IYIbrahim Yel
Ibrahim Yel
CBChristian Booz
Christian Booz
MAMoritz H. Albrecht
Moritz H. Albrecht
TGTatjana Gruber-Rouh
Tatjana Gruber-Rouh
CPChristoph Polkowski
Christoph Polkowski
BKBenjamin Kaltenbach
Benjamin Kaltenbach