Arash Atrsaei

Mr. Arash Atrsaei

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2020 in The Lancet Neurology
Verified
Journal Article
Closed access
EWElke Warmerdam
Elke Warmerdam
Jeffrey HausdorffJeffrey Hausdorff
Jeffrey Hausdorff
AAArash Atrsaei
Arash Atrsaei
YZYuhan Zhou
Yuhan Zhou
AMAnat Mirelman
Anat Mirelman
WMWalter Maetzler
Walter Maetzler

5 March 2021 in npj Parkinson's Disease
Verified
Journal Article
Open access
PDF file
AAArash Atrsaei
Arash Atrsaei
MCMarta Francisca Corrà
Marta Francisca Corrà
FDFarzin Dadashi
Farzin Dadashi
NVNuno Vila-Chã
Nuno Vila-Chã
LMLuis Maia
Luis Maia
Kamiar AminianKamiar Aminian
Kamiar Aminian
Gait speed often referred as the sixth vital sign is the most powerful biomarker of mobility. While a clinical setting allows the estimation of gait speed under controlled conditions that present functional capacity, gait speed in real-life conditions provides the actual performance of the patient. The goal of this study was to investigate objectively under what conditions during daily activities, patients perform as well as or better than in the clinic. To this end, we recruited 27 Parkinson’s disease (PD) patients and measured their gait speed by inertial measurement units through several walking tests in the clinic as well as their daily activities at home. By fitting a bimodal Gaussian model to their gait speed distribution, we found that on average, patients had similar modes in the clinic and during daily activities. Furthermore, we observed that the number of medication doses taken throughout the day had a moderate correlation with the difference between clinic and home. Performing a cycle-by-cycle analysis on gait speed during the home assessment, overall only about 3% of the strides had equal or greater gait speeds than the patients’ capacity in the clinic. These strides were during long walking bouts (>1 min) and happened before noon, around 26 min after medication intake, reaching their maximum occurrence probability 3 h after Levodopa intake. These results open the possibility of better control of medication intake in PD by considering both functional capacity and continuous monitoring of gait speed during real-life conditions.

2 August 2016 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
AAArash Atrsaei
Arash Atrsaei
HSHassan Salarieh
Hassan Salarieh
AAAria Alasty
Aria Alasty
Due to various applications of human motion capture techniques, developing low-cost methods that would be applicable in nonlaboratory environments is under consideration. MEMS inertial sensors and Kinect are two low-cost devices that can be utilized in home-based motion capture systems, e.g., home-based rehabilitation. In this work, an unscented Kalman filter approach was developed based on the complementary properties of Kinect and the inertial sensors to fuse the orientation data of these two devices for human arm motion tracking during both stationary shoulder joint position and human body movement. A new measurement model of the fusion algorithm was obtained that can compensate for the inertial sensors drift problem in high dynamic motions and also joints occlusion in Kinect. The efficiency of the proposed algorithm was evaluated by an optical motion tracker system. The errors were reduced by almost 50% compared to cases when either inertial sensor or Kinect measurements were utilized.

9 June 2021 in Sensors
Verified
Journal Article
Open access
PDF file
MCMarta Francisca Corrà
Marta Francisca Corrà
AAArash Atrsaei
Arash Atrsaei
ASAna Sardoreira
Ana Sardoreira
Clint HansenClint Hansen
Clint Hansen
Kamiar AminianKamiar Aminian
Kamiar Aminian
LMLuis Maia
Luis Maia
Accurate assessment of Parkinson’s disease (PD) ON and OFF states in the usual environment is essential for tailoring optimal treatments. Wearables facilitate measurements of gait in novel and unsupervised environments; however, differences between unsupervised and in-laboratory measures have been reported in PD. We aimed to investigate whether unsupervised gait speed discriminates medication states and which supervised tests most accurately represent home performance. In-lab gait speeds from different gait tasks were compared to home speeds of 27 PD patients at ON and OFF states using inertial sensors. Daily gait speed distribution was expressed in percentiles and walking bout (WB) length. Gait speeds differentiated ON and OFF states in the lab and the home. When comparing lab with home performance, ON assessments in the lab showed moderate-to-high correlations with faster gait speeds in unsupervised environment (r = 0.69; p < 0.001), associated with long WB. OFF gait assessments in the lab showed moderate correlation values with slow gait speeds during OFF state at home (r = 0.56; p = 0.004), associated with short WB. In-lab and daily assessments of gait speed with wearables capture additional integrative aspects of PD, reflecting different aspects of mobility. Unsupervised assessment using wearables adds complementary information to the clinical assessment of motor fluctuations in PD.

10 October 2017 in Journal of Intelligent & Robotic Systems
Verified
Journal Article
Closed access
PDF file
AAArash Atrsaei
Arash Atrsaei
HSHassan Salarieh
Hassan Salarieh
AAAria Alasty
Aria Alasty
MAMohammad Abediny
Mohammad Abediny

3 June 2020 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
AAArash Atrsaei
Arash Atrsaei
FDFarzin Dadashi
Farzin Dadashi
Clint HansenClint Hansen
Clint Hansen
EWElke Warmerdam
Elke Warmerdam
BMBenoît Mariani
Benoît Mariani
KAKamiar Aminian
Kamiar Aminian
Background: Sit-to-stand and stand-to-sit transitions are frequent daily functional tasks indicative of muscle power and balance performance. Monitoring these postural transitions with inertial sensors provides an objective tool to assess mobility in both the laboratory and home environment. While the measurement depends on the sensor location, the clinical and everyday use requires high compliance and subject adherence. The objective of this study was to propose a sit-to-stand and stand-to-sit transition detection algorithm that works independently of the sensor location. Methods: For a location-independent algorithm, the vertical acceleration of the lower back in the global frame was used to detect the postural transitions in daily activities. The detection performance of the algorithm was validated against video observations. To investigate the effect of the location on the kinematic parameters, these parameters were extracted during a five-time sit-to-stand test and were compared for different locations of the sensor on the trunk and lower back. Results: The proposed detection method demonstrates high accuracy in different populations with a mean positive predictive value (and mean sensitivity) of 98% (95%) for healthy individuals and 89% (89%) for participants with diseases. Conclusions: The sensor location around the waist did not affect the performance of the algorithm in detecting the sit-to-stand and stand-to-sit transitions. However, regarding the accuracy of the kinematic parameters, the sensors located on the sternum and L5 vertebrae demonstrated the highest reliability.