Ahmad A Almazloum

Dr. Ahmad A Almazloum

University of Campinas, São Paulo, Brazil
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 August 2022 in Computers
Verified
Journal Article
Open access
PDF file
AAAhmad A Almazloum
Ahmad A Almazloum
Abdel-Razzak Mohammad Al-HinnawiAbdel-Razzak Mohammad Al-Hinnawi
Abdel-Razzak Mohammad Al-Hinnawi
Roberto de FazioRoberto de Fazio
Roberto de Fazio
Paolo ViscontiPaolo Visconti
Paolo Visconti
The aim of the research work is to investigate the operability of the entire 23 pulmonary function parameters, which are stipulated by the American Thoracic Society (ATS) and the European Respiratory Society (ERS), to design a medical decision support system capable of classifying the pulmonary function tests into normal, obstructive, restrictive, or mixed cases. The 23 respiratory parameters specified by the ATS and the ERS guidelines, obtained from the Pulmonary Function Test (PFT) device, were employed as input features to a Multi-Layer Perceptron (MLP) neural network. Thirteen possible MLP Back Propagation (BP) algorithms were assessed. Three different categories of respiratory diseases were evaluated, namely obstructive, restrictive, and mixed conditions. The framework was applied on 201 PFT examinations: 103 normal and 98 abnormal cases. The PFT decision support system’s outcomes were compared with both the clinical truth (physician decision) and the PFT built-in diagnostic software. It yielded 92–99% and 87–92% accuracies on the training and the test sets, respectively. An 88–94% area under the receiver operating characteristic curve (ROC) was recorded on the test set. The system exceeded the performance of the PFT machine by 9%. All 23 ATS\ERS standard PFT parameters can be used as inputs to design a PFT decision support system, yielding a favorable performance compared with the literature and the PFT machine’s diagnosis program.


7 August 2025 in Medical Engineering & Physics
Verified
Journal Article
Closed access
AAAhmad A Almazloum
Ahmad A Almazloum
PGPaulo G. Gandra
Paulo G. Gandra
JBJosé W.M. Bassani
José W.M. Bassani
RBRosana A. Bassani
Rosana A. Bassani
High-intensity, external electric fields (HIEF) have been used in research and therapy for abnormal generation/propagation of the cardiac electrical activity (e.g., defibrillation), and for promoting access of membrane-impermeant molecules into the cytosol through electropores. This report proposes the architecture of a pulse generator designed for both pacing and electroporation induction in isolated myocytes for the study of HIEF impact and membrane repair mechanisms. The instrument was used for quantitative characterization and comparison of the sensitivity of myocytes isolated from skeletal and cardiac muscle to HIEF-induced lethal damage, which requires severe electroporation. The pulse generator was able to produce lethal injury in both cell types, even though skeletal myocytes required fields ∼50 % greater than cardiomyocytes, thus underscoring the suitability of the proposed instrument for electroporation induction in muscle cells. It is thus likely that the reported greater myocardial vulnerability to severe electrical injury, compared to other tissues, is due to the greater cardiomyocyte sensitivity to HIEF.